The DOI matches its Crossref record.
Rapid, sequence-specific detection of unpurified PCR amplicons via a reusable, electrochemical sensor
Abstract
We report an electrochemical method for the sequence-specific detection of unpurified amplification products of the gyrB gene of Salmonella typhimurium . Using an asymmetric PCR and the electrochemical E-DNA detection scheme, single-stranded amplicons were produced from as few as 90 gene copies and, without subsequent purification, rapidly identified. The detection is specific; the sensor does not respond when challenged with control oligonucleotides based on the gyrB genes of either Escherichia coli or various Shigella species. In contrast to existing sequence-specific optical- and capillary electrophoresis-based detection methods, the E-DNA sensor is fully electronic and requires neither cumbersome, expensive optics nor high voltage power supplies. Given these advantages, E-DNA sensors appear well suited for implementation in portable PCR microdevices directed at, for example, the rapid detection of pathogens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid Architectures
Lubin, A. A., & Plaxco, K. W. (2010) · Accounts of Chemical Research · doi:10.1021/ar900165x · Cited by 506
Self-citationXiao, Y., Lai, R. Y., & Plaxco, K. W. (2007) · Nature Protocols · doi:10.1038/nprot.2007.413 · Cited by 439
Self-citationAn Enzyme-Based E-DNA Sensor for Sequence-Specific Detection of Femtomolar DNA Targets
Liu, G., Wan, Y., Gau, V., Zhang, J., Wang, L., Song, S., & Fan, C. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800554t · Cited by 418
Rashid, J. I. A., & Yusof, N. A. (2017) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2017.09.001 · Cited by 300
An introduction to electrochemical DNA biosensors
Odenthal, K. J., & Gooding, J. J. (2007) · The Analyst · doi:10.1039/b701816a · Cited by 257
Metadata
- Authors
- Lai, R. Y., Lagally, E. T., Lee, S.-H., Soh, H. T., Plaxco, K. W., & Heeger, A. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-03-03
- Volume
- 103
- Issue
- 11
- Pages
- 4017-4021
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2158087427
- Cited by
- 177
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid, sequence-specific detection of unpurified PCR amplicons via a reusable, electrochemical sensor. https://app.cochat.ai/papers/10.1073/pnas.0511325103
- The paper
- Lai, R. Y., Lagally, E. T., Lee, S.-H., Soh, H. T., Plaxco, K. W., & Heeger, A. J. (2006). Rapid, sequence-specific detection of unpurified PCR amplicons via a reusable, electrochemical sensor. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0511325103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.