Array feature size influences nucleic acid surface capture in DNA microarrays
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Analyte affinity capture by surface-immobilized diagnostic agents is a routinely used assay format for profiling numerous medically and technologically important target analytes. These assays suffer from numerous performance limitations, including sensitivity and rapidity. Assay miniaturization is advocated to improve surface-capture performance, specifically exploiting the inverse relationship between analyte flux and capture feature size under mass transfer-limiting capture conditions that characterize many such assay formats. Reduced capture feature sizes, e.g., microarrays, are proposed to overcome mass transfer limitations, yet this is difficult to achieve across several size scales. This study validates certain advantages advocated for capture spot miniaturization using a rationale to understand surface capture miniaturization strategies. Experimentally derived immobilized ligand and target capture densities as a function of microspot size for DNA oligomers immobilized on model gold substrates are compared directly with theoretical analysis, validating the hypothesis that miniaturization yields many practical assay advantages. Specifically, results show that transitions from assay mass transfer limiting to kinetically limiting conditions as feature size decreases identify an optimal microspot size range for a specific bioassay system. Analytical advantages realized from such assay miniaturization are more uniform target-spot coverage and substantially increased rate of capture (hybridization), increasing assay signal and rapidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MAQC Consortium, Shi, L., Shi, L., Reid, L. H., Jones, W. D., Shippy, R., Warrington, J. A., Baker, S. C., Collins, P. J., de Longueville, F., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1239 · Cited by 2,126
Cited by
Coming of age: ten years of next-generation sequencing technologies
Goodwin, S., McPherson, J. D., & McCombie, W. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2016.49 · Cited by 4,352
Facile DNA immobilization on surfaces through a catecholamine polymer
Ham, H. O., Liu, Z., Lau, K. H. A., Lee, H., & Messersmith, P. B. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005001 · Cited by 189
Zhao, L., Dong, Q., Luo, C., Wu, Y., Bu, D., Qi, X., Luo, Y., & Zhao, Y. (2021) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2021.04.067 · Cited by 127
“The advent of high-throughput omics technologies, such as the next-generation sequencing [1], DNA microarrays [2], and DNA methylation arrays [3] enable the measurement of thousands of molecules at the same time from a biological sample comprehensively.”
BackgroundKlinghammer, S., Voitsekhivska, T., Licciardello, N., Kim, K., Baek, C.-K., Cho, H., Wolter, K.-J., Kirschbaum, C., Baraban, L., & Cuniberti, G. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02267 · Cited by 62
Metadata
- Authors
- Dandy, D. S., Wu, P., & Grainger, D. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-05-15
- Volume
- 104
- Issue
- 20
- Pages
- 8223-8228
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2150605180
- Cited by
- 77
- References
- 1
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Array feature size influences nucleic acid surface capture in DNA microarrays. https://app.cochat.ai/papers/10.1073/pnas.0606054104
- The paper
- Dandy, D. S., Wu, P., & Grainger, D. W. (2007). Array feature size influences nucleic acid surface capture in DNA microarrays. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0606054104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.