The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
G protein-coupled receptors sense fluid shear stress in endothelial cells
Open accessAbstract
Hemodynamic shear stress stimulates a number of intracellular events that both regulate vessel structure and influence development of vascular pathologies. The precise molecular mechanisms by which endothelial cells transduce this mechanical stimulus into intracellular biochemical response have not been established. Here, we show that mechanical perturbation of the plasma membrane leads to ligand-independent conformational transitions in a G protein-coupled receptor (GPCR). By using time-resolved fluorescence microscopy and GPCR conformation-sensitive FRET we found that stimulation of endothelial cells with fluid shear stress, hypotonic stress, or membrane fluidizing agent leads to a significant increase in activity of bradykinin B 2 GPCR in endothelial cells. The GPCR conformational dynamics was detected by monitoring redistribution of GPCRs between inactive and active conformations in a single endothelial cell under fluid shear stress in real time. We show that this response can be blocked by a B 2 -selective antagonist. Our data demonstrate that changes in cell membrane tension and membrane fluidity affect conformational dynamics of GPCRs. Therefore, we suggest that GPCRs are involved in mediating primary mechanochemical signal transduction in endothelial cells. We anticipate our experiments to be a starting point for more sophisticated studies of the effects of changes in lipid bilayer environment on GPCR conformational dynamics. Furthermore, because GPCRs are a major target of drug development, a detailed characterization of mechanochemical signaling via the GPCR pathway will be relevant for the development of new antiatherosclerosis drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reaction-rate theory: fifty years after Kramers
Hänggi, P., Talkner, P., & Borkovec, M. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.251 · Cited by 6,154
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Mechanical regulation of bone remodeling
Wang, L., You, X., Zhang, L., Zhang, C., & Zou, W. (2022) · Bone Research · doi:10.1038/s41413-022-00190-4 · Cited by 641
Cellular mechanotransduction in health and diseases: from molecular mechanism to therapeutic targets
Di, X., Gao, X., Peng, L., Ai, J., Jin, X., Qi, S., Li, H., Wang, K., & Luo, D. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01501-9 · Cited by 622
Mechanisms of Tooth Eruption and Orthodontic Tooth Movement
Wise, G. E., & King, G. J. (2008) · Journal of Dental Research · doi:10.1177/154405910808700509 · Cited by 582
Mechanical Signaling for Bone Modeling and Remodeling
Robling, A. G., & Turner, C. H. (2009) · Critical Reviews™ in Eukaryotic Gene Expression · doi:10.1615/critreveukargeneexpr.v19.i4.50 · Cited by 422
Vascular Mechanobiology Endothelial Cell Responses to Fluid Shear Stress
Ando, J., & Yamamoto, K. (2009) · Circulation Journal · doi:10.1253/circj.cj-09-0583 · Cited by 372
Metadata
- Authors
- Chachisvilis, M., Zhang, Y.-L., & Frangos, J. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-10-17
- Volume
- 103
- Issue
- 42
- Pages
- 15463-15468
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2058258523
- Cited by
- 491
- References
- 2
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: G protein-coupled receptors sense fluid shear stress in endothelial cells. https://app.cochat.ai/papers/10.1073/pnas.0607224103
- The paper
- Chachisvilis, M., Zhang, Y.-L., & Frangos, J. A. (2006). G protein-coupled receptors sense fluid shear stress in endothelial cells. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0607224103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.