Electrochemical attosyringe
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10 −18 to 10 −12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipofection: a highly efficient, lipid-mediated DNA-transfection procedure.
Felgner, P. L., Gadek, T. R., Holm, M., Roman, R., Chan, H. W., Wenz, M., Northrop, J. P., Ringold, G. M., & Danielsen, M. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.21.7413 · Cited by 4,978
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Principles of Selective Ion Transport in Channels and Pumps
Gouaux, E., & MacKinnon, R. (2005) · Science · doi:10.1126/science.1113666 · Cited by 1,059
Electroporation and Electrofusion in Cell Biology
(1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2 · Cited by 942
Current Rectification at Quartz Nanopipet Electrodes
Wei, C., Bard, A. J., & Feldberg, S. W. (1997) · Analytical Chemistry · doi:10.1021/ac970551g · Cited by 576
A cell nanoinjector based on carbon nanotubes
Chen, X., Kis, A., Zettl, A., & Bertozzi, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700567104 · Cited by 377
Electrostatic-Gated Transport in Chemically Modified Glass Nanopore Electrodes
Wang, G., Zhang, B., Wayment, J. R., Harris, J. M., & White, H. S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061357r · Cited by 200
Liu, B., Rotenberg, S. A., & Mirkin, M. V. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.18.9855 · Cited by 192
Self-citationA galinstan expansion femtosyringe for microinjection of eukaryotic organelles and prokaryotes
Knoblauch, M., Hibberd, J. M., Gray, J. C., & van Bel, A. J. E. (1999) · Nature Biotechnology · doi:10.1038/12902 · Cited by 177
Shao, Y., & Mirkin, M. V. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971824s · Cited by 168
Self-citationBruckbauer, A., Zhou, D., Ying, L., Korchev, Y. E., Abell, C., & Klenerman, D. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035755v · Cited by 120
High throughput easy microinjection with a single-cell manipulation supporting robot
Matsuoka, H., Komazaki, T., Mukai, Y., Shibusawa, M., Akane, H., Chaki, A., Uetake, N., & Saito, M. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.10.010 · Cited by 83
Lipid-Assisted Microinjection: Introducing Material into the Cytosol and Membranes of Small Cells
Laffafian, I., & Hallett, M. B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77700-8 · Cited by 52
Neugebauer, S., Evans, S. R., Aguilar, Z. P., Mosbach, M., Fritsch, I., & Schuhmann, W. W. (2003) · Analytical Chemistry · doi:10.1021/ac0346860 · Cited by 29
Gabriel, B., & Teissié, J. (1998) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(98)00174-3 · Cited by 21
Cunliffe, J. M., Sunahara, R. K., & Kennedy, R. T. (2006) · Analytical Chemistry · doi:10.1021/ac0521201 · Cited by 16
Cited by
Strategies for the intracellular delivery of nanoparticles
Chou, L. Y. T., Ming, K., & Chan, W. C. W. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00003e · Cited by 811
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
Meister, A., Gabi, M., Behr, P., Studer, P., Vörös, J., Niedermann, P., Bitterli, J., Polesel-Maris, J., Liley, M., Heinzelmann, H., et al. (2009) · Nano Letters · doi:10.1021/nl901384x · Cited by 459
Fundamental Studies of Nanofluidics: Nanopores, Nanochannels, and Nanopipets
Haywood, D. G., Saha-Shah, A., Baker, L. A., & Jacobson, S. C. (2015) · Analytical Chemistry · doi:10.1021/ac504180h · Cited by 270
Metadata
- Authors
- Laforge, F. O., Carpino, J., Rotenberg, S. A., & Mirkin, M. V.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-07-17
- Volume
- 104
- Issue
- 29
- Pages
- 11895-11900
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2572509048
- Cited by
- 174
- References
- 16
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.