The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The chemistrode: A droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution
Open accessAbstract
Microelectrodes enable localized electrical stimulation and recording, and they have revolutionized our understanding of the spatiotemporal dynamics of systems that generate or respond to electrical signals. However, such comprehensive understanding of systems that rely on molecular signals—e.g., chemical communication in multicellular neural, developmental, or immune systems—remains elusive because of the inability to deliver, capture, and interpret complex chemical information. To overcome this challenge, we developed the “chemistrode,” a plug-based microfluidic device that enables stimulation, recording, and analysis of molecular signals with high spatial and temporal resolution. Stimulation with and recording of pulses as short as 50 ms was demonstrated. A pair of chemistrodes fabricated by multilayer soft lithography recorded independent signals from 2 locations separated by 15 μm. Like an electrode, the chemistrode does not need to be built into an experimental system—it is simply brought into contact with a chemical or biological substrate, and, instead of electrical signals, molecular signals are exchanged. Recorded molecular signals can be injected with additional reagents and analyzed off-line by multiple, independent techniques in parallel (e.g., fluorescence correlation spectroscopy, MALDI-MS, and fluorescence microscopy). When recombined, these analyses provide a time-resolved chemical record of a system's response to stimulation. Insulin secretion from a single murine islet of Langerhans was measured at a frequency of 0.67 Hz by using the chemistrode. This article characterizes and tests the physical principles that govern the operation of the chemistrode to enable its application to probing local dynamics of chemically responsive matter in chemistry and biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citationBoedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901550 · Cited by 327
Self-citation
Metadata
- Authors
- Chen, D., Du, W., Liu, Y., Liu, W., Kuznetsov, A., Mendez, F. E., Philipson, L. H., & Ismagilov, R. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-11-04
- Volume
- 105
- Issue
- 44
- Pages
- 16843-16848
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1995713989
- Cited by
- 225
- References
- 1
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The chemistrode: A droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution. https://app.cochat.ai/papers/10.1073/pnas.0807916105
- The paper
- Chen, D., Du, W., Liu, Y., Liu, W., Kuznetsov, A., Mendez, F. E., Philipson, L. H., & Ismagilov, R. F. (2008). The chemistrode: A droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0807916105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.