The DOI matches its Crossref record.
Picomolar sensitivity MRI and photoacoustic imaging of cobalt nanoparticles
Open accessAbstract
Multimodality imaging based on complementary detection principles has broad clinical applications and promises to improve the accuracy of medical diagnosis. This means that a tracer particle advantageously incorporates multiple functionalities into a single delivery vehicle. In the present work, we explore a unique combination of MRI and photoacoustic tomography (PAT) to detect picomolar concentrations of nanoparticles. The nanoconstruct consists of ferromagnetic (Co) particles coated with gold (Au) for biocompatibility and a unique shape that enables optical absorption over a broad range of frequencies. The end result is a dual-modality probe useful for the detection of trace amounts of nanoparticles in biological tissues, in which MRI provides volume detection, whereas PAT performs edge detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Molecular imaging: current status and emerging strategies
Pysz, M. A., Gambhir, S. S., & Willmann, J. K. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.03.011 · Cited by 572
Nanoparticles as contrast agents for in-vivo bioimaging: current status and future perspectives
Hahn, M. A., Singh, A. K., Sharma, P., Brown, S. C., & Moudgil, B. M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4207-5 · Cited by 485
The acidic tumor microenvironment: a target for smart cancer nano-theranostics
Feng, L., Dong, Z., Tao, D., Zhang, Y., & Liu, Z. (2018) · National Science Review · doi:10.1093/nsr/nwx062 · Cited by 426
Structural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Metadata
- Authors
- Bouchard, L.-S., Anwar, M. S., Liu, G. L., Hann, B., Xie, Z. H., Gray, J. W., Wang, X., Pines, A., & Chen, F. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-03-17
- Volume
- 106
- Issue
- 11
- Pages
- 4085-4089
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2016320594
- Cited by
- 183
- References
- 0
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Picomolar sensitivity MRI and photoacoustic imaging of cobalt nanoparticles. https://app.cochat.ai/papers/10.1073/pnas.0813019106
- The paper
- Bouchard, L.-S., Anwar, M. S., Liu, G. L., Hann, B., Xie, Z. H., Gray, J. W., Wang, X., Pines, A., & Chen, F. F. (2009). Picomolar sensitivity MRI and photoacoustic imaging of cobalt nanoparticles. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0813019106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.