High-sensitivity microfluidic calorimeters for biological and chemical applications
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
High-sensitivity microfluidic calorimeters raise the prospect of achieving high-throughput biochemical measurements with minimal sample consumption. However, it has been challenging to realize microchip-based calorimeters possessing both high sensitivity and precise sample-manipulation capabilities. Here, we report chip-based microfluidic calorimeters capable of characterizing the heat of reaction of 3.5-nL samples with 4.2-nW resolution. Our approach, based on a combination of hard- and soft-polymer microfluidics, provides both exceptional thermal response and the physical strength necessary to construct high-sensitivity calorimeters that can be scaled to automated, highly multiplexed array architectures. Polydimethylsiloxane microfluidic valves and pumps are interfaced to parylene channels and reaction chambers to automate the injection of analyte at 1 nL and below. We attained excellent thermal resolution via on-chip vacuum encapsulation, which provides unprecedented thermal isolation of the minute microfluidic reaction chambers. We demonstrate performance of these calorimeters by resolving measurements of the heat of reaction of urea hydrolysis and the enthalpy of mixing of water with methanol. The device structure can be adapted easily to enable a wide variety of other standard calorimeter operations; one example, a flow calorimeter, is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid measurement of binding constants and heats of binding using a new titration calorimeter
Wiseman, T., Williston, S., Brandts, J. F., & Lin, L.-N. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90213-3 · Cited by 2,675
Cited by
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Self-citationLatest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Thermal Characterization and Analysis of Microliter Liquid Volumes Using the Three-Omega Method
Roy-Panzer, S., Kodama, T., Lingamneni, S., Panzer, M. A., Asheghi, M., & Goodson, K. E. (2015) · Review of Scientific Instruments · doi:10.1063/1.4907353 · Cited by 20
Metadata
- Authors
- Lee, W., Fon, W., Axelrod, B. W., & Roukes, M. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-09-08
- Volume
- 106
- Issue
- 36
- Pages
- 15225-15230
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2028789012
- Cited by
- 165
- References
- 1
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.