Quantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
X-ray fluorescence tomography promises to map elemental distributions in unstained and unfixed biological specimens in three dimensions at high resolution and sensitivity, offering unparalleled insight in medical, biological, and environmental sciences. X-ray fluorescence tomography of biological specimens has been viewed as impractical—and perhaps even impossible for routine application—due to the large time required for scanning tomography and significant radiation dose delivered to the specimen during the imaging process. Here, we demonstrate submicron resolution X-ray fluorescence tomography of a whole unstained biological specimen, quantifying three-dimensional distributions of the elements Si, P, S, Cl, K, Ca, Mn, Fe, Cu, and Zn in the freshwater diatom Cyclotella meneghiniana with 400-nm resolution, improving the spatial resolution by over an order of magnitude. The resulting maps faithfully reproduce cellular structure revealing unexpected patterns that may elucidate the role of metals in diatom biology and of diatoms in global element cycles. With anticipated improvements in data acquisition and detector sensitivity, such measurements could become routine in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primary production of the biosphere: Integrating terrestrial and oceanic components
Field, C. B., Behrenfeld, M. J., Randerson, J. T., & Falkowski, P. (1998) · Science · doi:10.1126/science.281.5374.237 · Cited by 6,371 · cited 1×
“Moreover diatoms account for approximately 20% of global carbon fixation (27) and facilitate the transport of photosynthetically fixed CO2 from the surface ocean to deep water (28).”
BackgroundPrinciples of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
The Biological Chemistry of the Elements: The Inorganic Chemistry of Life
Fraústo da Silva, J. J. R., & Williams, R. J. P. (2001) · doi:10.1093/oso/9780198508472.001.0001 · Cited by 1,005
The decoupling of production and particulate export in the surface ocean
Buesseler, K. O. (1998) · Global Biogeochemical Cycles · doi:10.1029/97gb03366 · Cited by 723
Martin, J. H., Gordon, M., & Fitzwater, S. E. (1991) · Limnology and Oceanography · doi:10.4319/lo.1991.36.8.1793 · Cited by 715
Cited by
Elemental and Chemically Specific X-ray Fluorescence Imaging of Biological Systems
Pushie, M. J., Pickering, I. J., Korbas, M., Hackett, M. J., & George, G. N. (2014) · Chemical Reviews · doi:10.1021/cr4007297 · Cited by 332
X-ray microtomography in biology
Mizutani, R., & Suzuki, Y. (2012) · Micron · doi:10.1016/j.micron.2011.10.002 · Cited by 217
“X-ray fluorescence microtomography at 400 nm resolution has been applied to subcellular imaging of the whole cell of a diatom, quantifying the 3D distributions of several elements (de Jonge et al., 2010).”
MethodNanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae
Deng, J., Vine, D. J., Chen, S., Nashed, Y. S. G., Jin, Q., Phillips, N. W., Peterka, T., Ross, R., Vogt, S., & Jacobsen, C. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1413003112 · Cited by 180
“Although we show here 2D images, both ptychography (39) and fluorescence (57) are compatible with tomographic approaches to nanoscale 3D imaging of biological materials.”
BackgroundSelf-citationThe Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities
Chen, S., Deng, J., Yuan, Y., Flachenecker, C., Mak, R., Hornberger, B., Jin, Q., Shu, D., Lai, B., Maser, J., et al. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s1600577513029676 · Cited by 177
“By using XFM with 400 nm spatial resolution, a recent study on dehydrated freshwater diatom revealed surprising metal distributions, particularly the ringlike structures formed by the distributions of manganese and iron in the siliceous cell wall (de Jonge et al., 2010).”
BackgroundSelf-citationAckerman, C. M., Lee, S., & Chang, C. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04631 · Cited by 177
Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications
Kaulich, B., Thibault, P., Gianoncelli, A., & Kiskinova, M. (2011) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/23/8/083002 · Cited by 169
“A notable recent advance in 3D imaging includes quantitative mapping of trace metals and other elements in Cyclotella meneghiniana by scanning x-ray fluorescence tomography (De Jonge et al 2010).”
BackgroundIron Utilization in Marine Cyanobacteria and Eukaryotic Algae
Morrissey, J., & Bowler, C. (2012) · Frontiers in Microbiology · doi:10.3389/fmicb.2012.00043 · Cited by 164
Metadata
- Authors
- de Jonge, M. D., Holzner, C., Baines, S. B., Twining, B. S., Ignatyev, K., Diaz, J., Howard, D. L., Legnini, D., Miceli, A., McNulty, I., Jacobsen, C. J., & Vogt, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-08-18
- Volume
- 107
- Issue
- 36
- Pages
- 15676-15680
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1996530735
- Cited by
- 161
- References
- 6
- FWCI
- 9.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.