The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities
Open accessAbstract
Hard X-ray fluorescence microscopy is one of the most sensitive techniques for performing trace elemental analysis of biological samples such as whole cells and tissues. Conventional sample preparation methods usually involve dehydration, which removes cellular water and may consequently cause structural collapse, or invasive processes such as embedding. Radiation-induced artifacts may also become an issue, particularly as the spatial resolution increases beyond the sub-micrometer scale. To allow imaging under hydrated conditions, close to the `natural state', as well as to reduce structural radiation damage, the Bionanoprobe (BNP) has been developed, a hard X-ray fluorescence nanoprobe with cryogenic sample environment and cryo transfer capabilities, dedicated to studying trace elements in frozen-hydrated biological systems. The BNP is installed at an undulator beamline at sector 21 of the Advanced Photon Source. It provides a spatial resolution of 30 nm for two-dimensional fluorescence imaging. In this first demonstration the instrument design and motion control principles are described, the instrument performance is quantified, and the first results obtained with the BNP on frozen-hydrated whole cells are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fahrni, C. J. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.02.039 · Cited by 297
Ortega, R., Devès, G., & Carmona, A. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0166.focus · Cited by 150
Cited by
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
ID16B: a hard X-ray nanoprobe beamline at the ESRF for nano-analysis
Martínez-Criado, G., Villanova, J., Tucoulou, R., Salomon, D., Suuronen, J.-P., Labouré, S., Guilloud, C., Valls, V., Barrett, R., Gagliardini, E., et al. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515019839 · Cited by 263
Flewett, S., Saintenoy, T., Sepúlveda, M., Mosso, E. F., Robles, C., Vega, K., Gutierrez, S., Romero, A., Finney, L., Maxey, E., et al. (2016) · Applied Spectroscopy · doi:10.1177/0003702816654153 · Cited by 10
Self-citation
Metadata
- Authors
- Chen, S., Deng, J., Yuan, Y., Flachenecker, C., Mak, R., Hornberger, B., Jin, Q., Shu, D., Lai, B., Maser, J., Roehrig, C., Paunesku, T., Gleber, S. C., Vine, D. J., Finney, L., VonOsinski, J., Bolbat, M., Spink, I., Chen, Z., Steele, J., Trapp, D., Irwin, J., Feser, M., Snyder, E., Brister, K., Jacobsen, C., Woloschak, G., & Vogt, S.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2013-12-12
- Volume
- 21
- Issue
- 1
- Pages
- 66-75
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2170780719
- Cited by
- 177
- References
- 2
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities. https://app.cochat.ai/papers/10.1107/s1600577513029676
- The paper
- Chen, S., Deng, J., Yuan, Y., Flachenecker, C., Mak, R., Hornberger, B., Jin, Q., Shu, D., Lai, B., Maser, J., Roehrig, C., Paunesku, T., Gleber, S. C., Vine, D. J., Finney, L., VonOsinski, J., Bolbat, M., Spink, I., Chen, Z., . . . Vogt, S. (2014). The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577513029676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.