The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
2D luminescence imaging of pH in vivo
Open accessAbstract
Luminescence imaging of biological parameters is an emerging field in biomedical sciences. Tools to study 2D pH distribution are needed to gain new insights into complex disease processes, such as wound healing and tumor metabolism. In recent years, luminescence-based methods for pH measurement have been developed. However, for in vivo applications, especially for studies on humans, biocompatibility and reliability under varying conditions have to be ensured. Here, we present a referenced luminescent sensor for 2D high-resolution imaging of pH in vivo. The ratiometric sensing scheme is based on time-domain luminescence imaging of FITC and ruthenium(II)tris-(4,7-diphenyl-1,10-phenanthroline). To create a biocompatible 2D sensor, these dyes were bound to or incorporated into microparticles (aminocellulose and polyacrylonitrile), and particles were immobilized in polyurethane hydrogel on transparent foils. We show sensor precision and validity by conducting in vitro and in vivo experiments, and we show the versatility in imaging pH during physiological and chronic cutaneous wound healing in humans. Implementation of this technique may open vistas in wound healing, tumor biology, and other biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Gurtner, G. C., Werner, S., Barrandon, Y., & Longaker, M. T. (2008) · Nature · doi:10.1038/nature07039 · Cited by 6,542
Singer, A. J., & Clark, R. A. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411006 · Cited by 6,106
Deriy, L. V., Gomez, E. A., Zhang, G., Beacham, D. W., Hopson, J. A., Gallan, A. J., Shevchenko, P. D., Bindokas, V. P., & Nelson, D. J. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.057372 · Cited by 135
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Self-citationThe Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Self-citationProksch, E. (2018) · The Journal of Dermatology · doi:10.1111/1346-8138.14489 · Cited by 590
Kong, B., Zhu, A., Ding, C., Zhao, X., Li, B., & Tian, Y. (2012) · Advanced Materials · doi:10.1002/adma.201202599 · Cited by 556
Metadata
- Authors
- Schreml, S., Meier, R. J., Wolfbeis, O. S., Landthaler, M., Szeimies, R.-M., & Babilas, P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-01-24
- Volume
- 108
- Issue
- 6
- Pages
- 2432-2437
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2047116831
- Cited by
- 216
- References
- 4
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2D luminescence imaging of pH in vivo. https://app.cochat.ai/papers/10.1073/pnas.1006945108
- The paper
- Schreml, S., Meier, R. J., Wolfbeis, O. S., Landthaler, M., Szeimies, R.-M., & Babilas, P. (2011). 2D luminescence imaging of pH in vivo. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1006945108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.