2D luminescence imaging of pH in vivo
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Luminescence imaging of biological parameters is an emerging field in biomedical sciences. Tools to study 2D pH distribution are needed to gain new insights into complex disease processes, such as wound healing and tumor metabolism. In recent years, luminescence-based methods for pH measurement have been developed. However, for in vivo applications, especially for studies on humans, biocompatibility and reliability under varying conditions have to be ensured. Here, we present a referenced luminescent sensor for 2D high-resolution imaging of pH in vivo. The ratiometric sensing scheme is based on time-domain luminescence imaging of FITC and ruthenium(II)tris-(4,7-diphenyl-1,10-phenanthroline). To create a biocompatible 2D sensor, these dyes were bound to or incorporated into microparticles (aminocellulose and polyacrylonitrile), and particles were immobilized in polyurethane hydrogel on transparent foils. We show sensor precision and validity by conducting in vitro and in vivo experiments, and we show the versatility in imaging pH during physiological and chronic cutaneous wound healing in humans. Implementation of this technique may open vistas in wound healing, tumor biology, and other biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Gurtner, G. C., Werner, S., Barrandon, Y., & Longaker, M. T. (2008) · Nature · doi:10.1038/nature07039 · Cited by 6,542
Singer, A. J., & Clark, R. A. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411006 · Cited by 6,106
A tissue-scale gradient of hydrogen peroxide mediates rapid wound detection in zebrafish
Niethammer, P., Grabher, C., Look, A. T., & Mitchison, T. J. (2009) · Nature · doi:10.1038/nature08119 · Cited by 1,541
Nagai, T., Yamada, S., Tominaga, T., Ichikawa, M., & Miyawaki, A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400417101 · Cited by 1,030
Bickers (2006) · doi:10.1016/j.jaad.2006.05.048 · Cited by 741
The impact of the pH value on skin integrity and cutaneous wound healing
Schreml, S., Szeimies, R., Karrer, S., Heinlin, J., Landthaler, M., & Babilas, P. (2010) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/j.1468-3083.2009.03413.x · Cited by 279
Self-citationDeriy, L. V., Gomez, E. A., Zhang, G., Beacham, D. W., Hopson, J. A., Gallan, A. J., Shevchenko, P. D., Bindokas, V. P., & Nelson, D. J. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.057372 · Cited by 135
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Self-citationLi, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Self-citationProksch, E. (2018) · The Journal of Dermatology · doi:10.1111/1346-8138.14489 · Cited by 590
Kong, B., Zhu, A., Ding, C., Zhao, X., Li, B., & Tian, Y. (2012) · Advanced Materials · doi:10.1002/adma.201202599 · Cited by 556
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Zhu, Y., Zhang, J., Song, J., Yang, J., Du, Z., Zhao, W., Guo, H., Wen, C., Li, Q., Sui, X., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201905493 · Cited by 538
Sensors and imaging for wound healing: A review
Dargaville, T. R., Farrugia, B. L., Broadbent, J. A., Pace, S., Upton, Z., & Voelcker, N. H. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.029 · Cited by 457
The Effect of pH on the Extracellular Matrix and Biofilms
Jones, E. M., Cochrane, C. A., & Percival, S. L. (2015) · Advances in Wound Care · doi:10.1089/wound.2014.0538 · Cited by 455
Hydrogel Dressings for Advanced Wound Management
Francesko, A., Petkova, P., & Tzanov, T. (2019) · Current Medicinal Chemistry · doi:10.2174/0929867324666170920161246 · Cited by 269
Flexible pH‐Sensing Hydrogel Fibers for Epidermal Applications
Tamayol, A., Akbari, M., Zilberman, Y., Comotto, M., Lesha, E., Serex, L., Bagherifard, S., Chen, Y., Fu, G., Ameri, S. K., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500553 · Cited by 262
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
Metadata
- Authors
- Schreml, S., Meier, R. J., Wolfbeis, O. S., Landthaler, M., Szeimies, R.-M., & Babilas, P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-01-24
- Volume
- 108
- Issue
- 6
- Pages
- 2432-2437
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2047116831
- Cited by
- 216
- References
- 8
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.