Claudin-4 forms paracellular chloride channel in the kidney and requires claudin-8 for tight junction localization
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tight junctions (TJs) play a key role in mediating paracellular ion reabsorption in the kidney. The paracellular pathway in the collecting duct of the kidney is a predominant route for transepithelial chloride reabsorption that determines the extracellular NaCl content and the blood pressure. However, the molecular mechanisms underlying the paracellular chloride reabsorption in the collecting duct are not understood. Here we showed that in mouse kidney collecting duct cells, claudin-4 functioned as a Cl – channel. A positively charged lysine residue at position 65 of claudin-4 was critical for its anion selectivity. Claudin-4 was observed to interact with claudin-8 using several criteria. In the collecting duct cells, the assembly of claudin-4 into TJ strands required its interaction with claudin-8. Depletion of claudin-8 resulted in the loss of paracellular chloride conductance, through a mechanism involving its recruitment of claudin-4 during TJ assembly. Together, our data show that claudin-4 interacts with claudin-8 and that their association is required for the anion-selective paracellular pathway in the collecting duct, suggesting a mechanism for coupling chloride reabsorption with sodium reabsorption in the collecting duct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Mechanisms of Human Hypertension
Lifton, R. P., Gharavi, A. G., & Geller, D. S. (2001) · Cell · doi:10.1016/s0092-8674(01)00241-0 · Cited by 1,686
Colegio, O. R., Itallie, C. V., Rahner, C., & Anderson, J. M. (2003) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00547.2002 · Cited by 387
Cited by
Claudins and the Modulation of Tight Junction Permeability
Günzel, D., & Yu, A. S. L. (2013) · Physiological Reviews · doi:10.1152/physrev.00019.2012 · Cited by 1,456
Intestinal epithelial claudins: expression and regulation in homeostasis and inflammation
Garcia‐Hernandez, V., Quiros, M., & Nusrat, A. (2017) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13360 · Cited by 445
Role of CFTR in epithelial physiology
Saint-Criq, V., & Gray, M. A. (2017) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-016-2391-y · Cited by 433
“with properties very similar to conventional membrane spanning ion channels [6] Transepithelial electrical resistance (TEER) measurement is used to assess the barrier function of epithelial tissues, or cells grown on semi-permeable supports, and reflects the paracellular as well as transcellular conductivity.”
MethodClaudins and Other Tight Junction Proteins
Günzel, D., & Fromm, M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110045 · Cited by 369
Tight junction, selective permeability, and related diseases
Krug, S. M., Schulzke, J. D., & Fromm, M. (2014) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2014.09.002 · Cited by 306
Cong, X., & Kong, W. (2020) · Cellular Signalling · doi:10.1016/j.cellsig.2019.109485 · Cited by 302
Esaki, H., Ewald, D. A., Ungar, B., Rozenblit, M., Zheng, X., Xu, H., Estrada, Y. D., Peng, X., Mitsui, H., Litman, T., et al. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2014.10.037 · Cited by 219
“Prior mouse and human skin equivalent models demonstrated that CLDN4 colocalized with CLDN1 to the epidermal granular layer,(39,40) whereas CLDN8 was previously shown in human kidneys and intestines.(41,42) Nevertheless, our knowledge of claudins and their involvement in the barrier alterations seen in patients with A…”
BackgroundTight junctions in pulmonary epithelia during lung inflammation
Wittekindt, O. H. (2017) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-016-1917-3 · Cited by 210
“Cldn8mediated sealing of TJ to Na parallels Na absorption in human colon cells [52], and hence, it is proposed that cldn8 augments sodium resorption by preventing paracellular leakage of Pflugers Arch - Eur J Physiol (2017) 469:135–147 139”
BackgroundThe Urothelium: Life in a Liquid Environment
Dalghi, M. G., Montalbetti, N., Carattino, M. D., & Apodaca, G. (2020) · Physiological Reviews · doi:10.1152/physrev.00041.2019 · Cited by 201
Mechanisms and Regulation of Intestinal Phosphate Absorption
Hernando, N., & Wagner, C. A. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c170024 · Cited by 70
Steelant, B., Seys, S. F., Boeckxstaens, G., Akdis, C. A., Ceuppens, J. L., & Hellings, P. W. (2017) · Rhinology journal · doi:10.4193/rhin15.376 · Cited by 47
“The pore forming claudins, such as claudin-2 (18) and claudin-7 (19) increase the permeability to anions/cations, while the barrier forming claudins such as claudin-1 (20) and claudin-4 (21) tighten the epithelial barrier function, with the reduction in cation/anion permeability (22) .”
Metadata
- Authors
- Hou, J., Renigunta, A., Yang, J., & Waldegger, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-10-04
- Volume
- 107
- Issue
- 42
- Pages
- 18010-18015
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1979207410
- Cited by
- 236
- References
- 2
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.