Using mechanobiological mimicry of red blood cells to extend circulation times of hydrogel microparticles
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
It has long been hypothesized that elastic modulus governs the biodistribution and circulation times of particles and cells in blood; however, this notion has never been rigorously tested. We synthesized hydrogel microparticles with tunable elasticity in the physiological range, which resemble red blood cells in size and shape, and tested their behavior in vivo. Decreasing the modulus of these particles altered their biodistribution properties, allowing them to bypass several organs, such as the lung, that entrapped their more rigid counterparts, resulting in increasingly longer circulation times well past those of conventional microparticles. An 8-fold decrease in hydrogel modulus correlated to a greater than 30-fold increase in the elimination phase half-life for these particles. These results demonstrate a critical design parameter for hydrogel microparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Factors affecting the clearance and biodistribution of polymeric nanoparticles
Alexis, F., Pridgen, E., Molnar, L. K., & Farokhzad, O. C. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800051m · Cited by 3,699 · cited 1×
“Such deformable and long-circulating particles may find utility in the fields of drug delivery and medical imaging, where long-circulation times and varied biodistributions are often desirable characteristics (6, 16, 17).”
BackgroundThe effect of particle design on cellular internalization pathways
Gratton, S. E. A., Ropp, P. A., Pohlhaus, P. D., Luft, J. C., Madden, V. J., Napier, M. E., & DeSimone, J. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801763105 · Cited by 2,918 · cited 2×
“For the PRINT technique (9, 18), master templates were prepared via traditional photolithography to have ordered arrays of raised discs with low aspect ratios, mimicking the shape of RBCs.”
MethodSelf-citationBiomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Shape effects of filaments versus spherical particles in flow and drug delivery
Geng, Y., Dalhaimer, P., Cai, S., Tsai, R., Tewari, M., Minko, T., & Discher, D. E. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.70 · Cited by 2,565
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669 · cited 1×
“Many hydrogels exhibit excellent biocompatibility (21), with their swelling and deformability controllable by varying the amount of cross-linking in the gel (22).”
BackgroundPhysical approaches to biomaterial design
Mitragotri, S., & Lahann, J. (2009) · Nature Materials · doi:10.1038/nmat2344 · Cited by 1,445
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284 · cited 2×
“Beyond RBCs, cancer cells, especially metastatic cancer cells, are elastically softer than healthy cells, a characteristic that is believed to be integral to their ability to spread to new locations (1, 4).”
BackgroundOptimizing Liposomes for Delivery of Chemotherapeutic Agents to Solid Tumors
Drummond, D. C., Meyer, O., Hong, K., Kirpotin, D. B., & Papahadjopoulos, D. (1999) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01426-1 · Cited by 1,263
Particle shape: A new design parameter for micro- and nanoscale drug delivery carriers
Champion, J. A., Katare, Y. K., & Mitragotri, S. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.03.022 · Cited by 1,206
Role of Particle Size in Phagocytosis of Polymeric Microspheres
Champion, J. A., Walker, A., & Mitragotri, S. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9562-y · Cited by 888
Direct Fabrication and Harvesting of Monodisperse, Shape-Specific Nanobiomaterials
Rolland, J. P., Maynor, B. W., Euliss, L. E., Exner, A. E., Denison, G. M., & DeSimone, J. M. (2005) · Journal of the American Chemical Society · doi:10.1021/ja051977c · Cited by 852
Self-citationSoluble Polymer Carriers for the Treatment of Cancer: The Importance of Molecular Architecture
Fox, M. E., Szoka, F. C., & Fréchet, J. M. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar900035f · Cited by 748
Microparticles and nanoparticles for drug delivery
Kohane, D. S. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21301 · Cited by 517
Brown, A. M. (2001) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00124-3 · Cited by 506
REHFELDT, F., ENGLER, A., ECKHARDT, A., AHMED, F., & DISCHER, D. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.007 · Cited by 405
Red blood cell-mimicking synthetic biomaterial particles
Doshi, N., Zahr, A. S., Bhaskar, S., Lahann, J., & Mitragotri, S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907127106 · Cited by 374
Stiffness of normal and pathological erythrocytes studied by means of atomic force microscopy
Dulińska, I., Targosz, M., Strojny, W., Lekka, M., Czuba, P., Balwierz, W. A., & Szymoński, M. (2006) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2005.11.003 · Cited by 307
Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries
McWhirter, J. L., Noguchi, H., & Gompper, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811484106 · Cited by 300
Cytoskeletal dynamics of human erythrocyte
Li, J., Lykotrafitis, G., Dao, M., & Suresh, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700257104 · Cited by 270
Drug–Induced Liver Injury: Mechanisms and Test Systems
Bissell, M. D., Gores, G. J., Laskin, D. L., & Hoofnagle, J. H. (2001) · Hepatology · doi:10.1053/jhep.2001.23505 · Cited by 267
Gratton, S. E. A., Pohlhaus, P. D., Lee, J., Guo, J., Cho, M. J., & DeSimone, J. M. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.05.027 · Cited by 266
Self-citationMerkel, T. J., Herlihy, K. P., Nunes, J., Orgel, R. M., Rolland, J. P., & DeSimone, J. M. (2010) · Langmuir · doi:10.1021/la903890h · Cited by 228
Self-citationSmith, B. R., Cheng, Z., De, A., Koh, A. L., Sinclair, R., & Gambhir, S. S. (2008) · Nano Letters · doi:10.1021/nl080141f · Cited by 213
Recognizing Drug-Induced Liver Injury: Current Problems, Possible Solutions
Lee, W. M., & Senior, J. R. (2005) · Toxicologic Pathology · doi:10.1080/01926230590522356 · Cited by 190
Elastic clues in cancer detection
Suresh, S. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.397 · Cited by 177
Top‐down particle fabrication: control of size and shape for diagnostic imaging and drug delivery
Canelas, D. A., Herlihy, K. P., & DeSimone, J. M. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.40 · Cited by 173
Self-citationMicrogel Translocation through Pores under Confinement
Hendrickson, G. R., & Lyon, L. A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906606 · Cited by 146
Squishy Non‐Spherical Hydrogel Microparticles
Haghgooie, R., Toner, M., & Doyle, P. S. (2010) · Macromolecular Rapid Communications · doi:10.1002/marc.200900302 · Cited by 125
Chronic measurement of cardiac output in conscious mice
Janssen, B. J., Debets, J., Leenders, P. J. A., & Smits, J. F. M. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00406.2001 · Cited by 101
Fattorossi, A., Nisini, R., Pizzolo, J. G., & D’Amelio, R. (1989) · Cytometry · doi:10.1002/cyto.990100311 · Cited by 96
Sandanaraj, B. S., Gremlich, H., Kneuer, R., Dawson, J., & Wacha, S. (2009) · Bioconjugate Chemistry · doi:10.1021/bc900311h · Cited by 73
Nanoparticle pharmacokinetic profiling in vivo using magnetic resonance imaging
Neubauer, A. M., Sim, H., Winter, P. M., Caruthers, S. D., Williams, T. A., Robertson, J. D., Sept, D., Lanza, G. M., & Wickline, S. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21795 · Cited by 68
Tong, L., He, W., Zhang, Y., Zheng, W., & Cheng, J. (2009) · Langmuir · doi:10.1021/la902992w · Cited by 51
(2002) · Humana Press eBooks · doi:10.1007/978-1-59259-124-4 · Cited by 43
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
“The discrepancy is likely due to the deformable nature of PRINT hydrogel NPs; it has been previously demonstrated that flexible PRINT NPs were eliminated from blood circulation significantly slower than their rigid counterparts [63].”
Erythrocyte membrane-camouflaged polymeric nanoparticles as a biomimetic delivery platform
Hu, C.-M. J., Zhang, L., Aryal, S., Cheung, C., Fang, R. H., & Zhang, L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106634108 · Cited by 2,433
Targeted polymeric therapeutic nanoparticles: design, development and clinical translation
Kamaly, N., Xiao, Z., Valencia, P. M., Radovic-Moreno, A. F., & Farokhzad, O. C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15344k · Cited by 1,730
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Nanoparticle–liver interactions: Cellular uptake and hepatobiliary elimination
Zhang, Y.-N., Poon, W., Tavares, A. J., McGilvray, I. D., & Chan, W. C. W. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.01.020 · Cited by 1,349
Metadata
- Authors
- Merkel, T. J., Jones, S. W., Herlihy, K. P., Kersey, F. R., Shields, A. R., Napier, M., Luft, J. C., Wu, H., Zamboni, W. C., Wang, A. Z., Bear, J. E., & DeSimone, J. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-01-04
- Volume
- 108
- Issue
- 2
- Pages
- 586-591
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1987769702
- Cited by
- 548
- References
- 35
- FWCI
- 20.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.