Cited by 117Magnetic and transport properties of perovskites and related materialsAdvanced Condensed Matter PhysicsMagnetism in coordination complexes

Magnetocaloric effect and magnetic cooling near a field-induced quantum-critical point

Open access
Wolf, Bernd, Tsui, Yeekin, Jaiswal-Nagar, Deepshikha, Tutsch, Ulrich, Honecker, Andreas, Remović-Langer, Katarina, Hofmann, Georg, Prokofiev, Andrey +3 more·2011·Proceedings of the National Academy of Sciences

Abstract

The presence of a quantum-critical point (QCP) can significantly affect the thermodynamic properties of a material at finite temperatures T . This is reflected, e.g., in the entropy landscape S ( T , r ) in the vicinity of a QCP, yielding particularly strong variations for varying the tuning parameter r such as pressure or magnetic field B . Here we report on the determination of the critical enhancement of ∂ S /∂ B near a B -induced QCP via absolute measurements of the magnetocaloric effect (MCE), (∂ T /∂ B ) S and demonstrate that the accumulation of entropy around the QCP can be used for efficient low-temperature magnetic cooling. Our proof of principle is based on measurements and theoretical calculations of the MCE and the cooling performance for a Cu 2+ -containing coordination polymer, which is a very good realization of a spin-½ antiferromagnetic Heisenberg chain—one of the simplest quantum-critical systems.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.1017047108

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The magnetic-field fluctuation in the flat-top region is ±0.005 T, which would only cause a small temperature fluctuation of ±0.002 K even in a material with a large magnetocaloric effect of ∼0.4 K/T, indicating field stability is good enough for the present method.

    “It is important to note that the magnetic-field fluctuation in the flattop region is ±0.005T, which would only cause a small temperature fluctuation of ±0.002K even in a material with a large magnetocaloric effect of ∼0.4 K/T such as a magnetic refrigerant material, 40 indicating that the field stability is good enough for the present method.”

    From Simultaneous measurement of specific heat and thermal conductivity in pulsed magnetic fields (2023) · cites this paper as [40]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 3

  1. Lounasmaa O V (1974) Experimental Principles And Methods Below 1 K. (Academic Press, New York).
  2. Sachdev S (1999) Quantum Phase Transitions (Cambridge University Press, Cambridge, England).
  3. Pobell F (1992) Matter And Methods At Low Temperatures. (Springer Berlin Heidelberg New York).

Cited by

Sorted by citations

Authors
Wolf, B., Tsui, Y., Jaiswal-Nagar, D., Tutsch, U., Honecker, A., Remović-Langer, K., Hofmann, G., Prokofiev, A., Assmus, W., Donath, G., & Lang, M.
Affiliations
  • Goethe University Frankfurt (DE)
  • Physics Institute, Goethe-University, Max-von-Laue Strasse 1, 60438 Frankfurt(Main), Germany;
  • University of Göttingen (DE)
  • TU Wien (AT)
  • Max Planck Institute for Chemical Physics of Solids (DE)
Venue
Proceedings of the National Academy of Sciences
Published
2011-04-08
Volume
108
Issue
17
Pages
6862-6866
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2073935308
Cited by
117
References
0
Citations by year
2026: 15 · 2025: 11 · 2024: 8 · 2023: 8 · 2022: 8 · 2021: 12 · 2020: 7 · 2019: 7 · 2018: 3 · 2017: 8 · 2016: 4 · 2015: 4 · 2014: 9 · 2013: 7 · 2012: 4
FWCI
2.81
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • HAL (submittedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • Max Planck Digital Library (submittedVersion)
  • GRO (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
  • arXiv (Cornell University)
Funders
Deutsche Forschungsgemeinschaft (SFB/TR 49)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic and transport properties of perovskites and related materials
  • Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Advanced Condensed Matter Physics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetism in coordination complexes
Keywords
magnetocaloric effect, magnetic refrigeration, quantum critical point, entropy accumulation, coordination polymers, Cu2S, low-temperature refrigeration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review