The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities
Open accessAbstract
We present a programmable droplet-based microfluidic device that combines the reconfigurable flow-routing capabilities of integrated microvalve technology with the sample compartmentalization and dispersion-free transport that is inherent to droplets. The device allows for the execution of user-defined multistep reaction protocols in 95 individually addressable nanoliter-volume storage chambers by consecutively merging programmable sequences of picoliter-volume droplets containing reagents or cells. This functionality is enabled by “flow-controlled wetting,” a droplet docking and merging mechanism that exploits the physics of droplet flow through a channel to control the precise location of droplet wetting. The device also allows for automated cross-contamination-free recovery of reaction products from individual chambers into standard microfuge tubes for downstream analysis. The combined features of programmability, addressability, and selective recovery provide a general hardware platform that can be reprogrammed for multiple applications. We demonstrate this versatility by implementing multiple single-cell experiment types with this device: bacterial cell sorting and cultivation, taxonomic gene identification, and high-throughput single-cell whole genome amplification and sequencing using common laboratory strains. Finally, we apply the device to genome analysis of single cells and microbial consortia from diverse environmental samples including a marine enrichment culture, deep-sea sediments, and the human oral cavity. The resulting datasets capture genotypic properties of individual cells and illuminate known and potentially unique partnerships between microbial community members.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A systems approach to measuring the binding energy landscapes of transcription factors.
Maerkl, S. J., & Quake, S. R. (2007) · Science · doi:10.1126/science.1131007 · Cited by 584
Microdroplet-based PCR enrichment for large-scale targeted sequencing
Tewhey, R., Warner, J. B., Nakano, M., Libby, B., Medkova, M., David, P. H., Kotsopoulos, S. K., Samuels, M. L., Hutchison, J. B., Larson, J. W., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1583 · Cited by 454 · cited 2×
“Two-phase flow systems that manipulate picoliter (pL) volume droplets in closed channels have been shown to be ideally suited to high-speed serial analysis for use in high-throughput screening applications (11) and sample preparation for genomics (12), while the programmable manipulation of nanoliter (nL) volume dropl…”
Background
Cited by
Single-cell genome sequencing: current state of the science
Gawad, C., Koh, W., & Quake, S. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2015.16 · Cited by 1,334
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
Active droplet generation in microfluidics
Chong, Z. Z., Tan, S. H., Gañán-Calvo, A. M., Tor, S. B., Loh, N. H., & Nguyen, N.-T. (2016) · Lab on a Chip · doi:10.1039/c5lc01012h · Cited by 297
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Metadata
- Authors
- Leung, K., Zahn, H., Leaver, T., Konwar, K. M., Hanson, N. W., Pagé, A. P., Lo, C.-C., Chain, P. S., Hallam, S. J., & Hansen, C. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-04-30
- Volume
- 109
- Issue
- 20
- Pages
- 7665-7670
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2105776288
- Cited by
- 243
- References
- 2
- FWCI
- 13.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities. https://app.cochat.ai/papers/10.1073/pnas.1106752109
- The paper
- Leung, K., Zahn, H., Leaver, T., Konwar, K. M., Hanson, N. W., Pagé, A. P., Lo, C.-C., Chain, P. S., Hallam, S. J., & Hansen, C. L. (2012). A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1106752109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.