A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
We present a programmable droplet-based microfluidic device that combines the reconfigurable flow-routing capabilities of integrated microvalve technology with the sample compartmentalization and dispersion-free transport that is inherent to droplets. The device allows for the execution of user-defined multistep reaction protocols in 95 individually addressable nanoliter-volume storage chambers by consecutively merging programmable sequences of picoliter-volume droplets containing reagents or cells. This functionality is enabled by “flow-controlled wetting,” a droplet docking and merging mechanism that exploits the physics of droplet flow through a channel to control the precise location of droplet wetting. The device also allows for automated cross-contamination-free recovery of reaction products from individual chambers into standard microfuge tubes for downstream analysis. The combined features of programmability, addressability, and selective recovery provide a general hardware platform that can be reprogrammed for multiple applications. We demonstrate this versatility by implementing multiple single-cell experiment types with this device: bacterial cell sorting and cultivation, taxonomic gene identification, and high-throughput single-cell whole genome amplification and sequencing using common laboratory strains. Finally, we apply the device to genome analysis of single cells and microbial consortia from diverse environmental samples including a marine enrichment culture, deep-sea sediments, and the human oral cavity. The resulting datasets capture genotypic properties of individual cells and illuminate known and potentially unique partnerships between microbial community members.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Tumour evolution inferred by single-cell sequencing
Navin, N., Kendall, J., Troge, J., Andrews, P., Rodgers, L., McIndoo, J., Cook, K., Stepansky, A., Levy, D., Esposito, D., et al. (2011) · Nature · doi:10.1038/nature09807 · Cited by 2,598 · cited 1×
“We note that this should be regarded as a lower bound because PCRbased WGA amplification is known to exhibit large bias (24) and may result in preferential amplification of genomic regions other than the one targeted by our assay.”
BackgroundThe motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313 · cited 1×
“A droplet flowing down a channel filled with an immiscible carrier fluid is separated from the channel walls by a thin lubricating film, the thickness of which is a function of droplet velocity (18).”
BackgroundMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222 · cited 3×
“Cultures were seeded with (1) single cells (dark parts of the array are unsuccessful cultures), (2) a single cell of each strain, (3) approximately 1,000 cells of each strain, (4) approximately 100 cells of each strain, (5) approximately 10 cells of each strain, (6) approximately 100 GFP-expressing cells, and (7) appr…”
BackgroundMethodIntegrative analysis of environmental sequences using MEGAN4
Huson, D. H., Mitra, S., Ruscheweyh, H.-J., Weber, N., & Schuster, S. C. (2011) · Genome Research · doi:10.1101/gr.120618.111 · Cited by 1,541 · cited 1×
“Results from the ref_seq search were then mapped onto the NCBI taxonomic hierarchy using metagenome analyzer (MEGAN) to define the most probable ancestor for each query sequence (27).”
MethodUltrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149 · cited 1×
“Two-phase flow systems that manipulate picoliter (pL) volume droplets in closed channels have been shown to be ideally suited to high-speed serial analysis for use in high-throughput screening applications (11) and sample preparation for genomics (12), while the programmable manipulation of nanoliter (nL) volume dropl…”
BackgroundDripping to Jetting Transitions in Coflowing Liquid Streams
Utada, A. S., Fernandez-Nieves, A., Stone, H. A., & Weitz, D. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.094502 · Cited by 965 · cited 1×
“This stream, formed by applying equal pressures to a buffer and an oil inlet that join at a T-junction (21), coalesces with the stored droplet until it exceeds the chamber capacity.”
BackgroundMicrofluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737 · cited 2×
“Overall, the success rate of PCR amplification from single cells was 41 of 59 (69%), which is comparable to previous reports (14, 22).”
BackgroundResultTice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Marcy, Y., Ouverney, C., Bik, E. M., Lösekann, T., Ivanova, N., Martin, H. G., Szeto, E., Platt, D., Hugenholtz, P., Relman, D. A., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704662104 · Cited by 634 · cited 1×
“This high level of integration enables device architectures capable of executing thousands of predefined “unit cell” reactions in parallel, with applications ranging from protein structure (4) and interaction studies (7, 8) to single-cell analysis and genomics (2, 9, 10).”
Background
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Single-cell genome sequencing: current state of the science
Gawad, C., Koh, W., & Quake, S. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2015.16 · Cited by 1,334
Innovations to culturing the uncultured microbial majority
Lewis, W. H., Tahon, G., Geesink, P., Sousa, D. Z., & Ettema, T. J. G. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-020-00458-8 · Cited by 605
Synthetic microbial communities
Großkopf, T., & Soyer, O. S. (2014) · Current Opinion in Microbiology · doi:10.1016/j.mib.2014.02.002 · Cited by 550
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Scaling by shrinking: empowering single-cell 'omics' with microfluidic devices
Prakadan, S. M., Shalek, A. K., & Weitz, D. A. (2017) · Nature Reviews Genetics · doi:10.1038/nrg.2017.15 · Cited by 325
New and developing diagnostic technologies for urinary tract infections
Davenport, M., Mach, K. E., Shortliffe, L. M. D., Banaei, N., Wang, T.-H., & Liao, J. C. (2017) · Nature Reviews Urology · doi:10.1038/nrurol.2017.20 · Cited by 321
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
The future is now: single-cell genomics of bacteria and archaea
Blainey, P. C. (2013) · FEMS Microbiology Reviews · doi:10.1111/1574-6976.12015 · Cited by 299
Active droplet generation in microfluidics
Chong, Z. Z., Tan, S. H., Gañán-Calvo, A. M., Tor, S. B., Loh, N. H., & Nguyen, N.-T. (2016) · Lab on a Chip · doi:10.1039/c5lc01012h · Cited by 297
Better together: engineering and application of microbial symbioses
Hays, S. G., Patrick, W. G., Ziesack, M., Oxman, N., & Silver, P. A. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.08.008 · Cited by 276
Metabolic interactions in microbial communities: untangling the Gordian knot
Ponomarova, O., & Patil, K. R. (2015) · Current Opinion in Microbiology · doi:10.1016/j.mib.2015.06.014 · Cited by 271
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
New Technologies for Studying Biofilms
Franklin, M. J., Chang, C., Akiyama, T., & Bothner, B. (2015) · Microbiology Spectrum · doi:10.1128/microbiolspec.mb-0016-2014 · Cited by 233
Microfluidic single cell analysis: from promise to practice
Lecault, V., White, A. K., Singhal, A., & Hansen, C. L. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.03.022 · Cited by 229
“com New developments in programmable microfluidic devices will also be important in providing a general fluid-handling platform that may be adapted to niche or user-specific applications [49,80,81].”
BackgroundSelf-citationGenomic sequencing of uncultured microorganisms from single cells
Lasken, R. S. (2012) · Nature Reviews Microbiology · doi:10.1038/nrmicro2857 · Cited by 219
Kovarik, M. L., Ornoff, D. M., Melvin, A. T., Dobes, N. C., Wang, Y., Dickinson, A. J., Gach, P. C., Shah, P. K., & Allbritton, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac3031543 · Cited by 218
Stepanauskas, R., Fergusson, E. A., Brown, J., Poulton, N. J., Tupper, B., Labonté, J. M., Becraft, E. D., Brown, J. M., Pachiadaki, M. G., Povilaitis, T., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00128-z · Cited by 203
Hou, Y., Wu, K., Shi, X., Li, F., Song, L., Wu, H., Dean, M., Li, G., Tsang, S., Jiang, R., et al. (2015) · Gigascience · doi:10.1186/s13742-015-0068-3 · Cited by 191
“Currently, three WGA strategies are widely used for SCRS: degenerate-oligonucleotide-primed polymerase chain reaction (DOP-PCR) [11, 12], multiple displacement amplification (MDA) [13–15], and a combination of displacement pre-amplification and PCR amplification (marketed as PicoPlex kit by Rubicon Genomics [16, 17],…”
MethodHigh-Throughput Single-Cell Cultivation on Microfluidic Streak Plates
Jiang, C.-Y., Dong, L., Zhao, J.-K., Hu, X., Shen, C., Qiao, Y., Zhang, X., Wang, Y., Ismagilov, R. F., Liu, S.-J., et al. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.03588-15 · Cited by 184
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
The trajectory of microbial single-cell sequencing
Woyke, T., Doud, D. F. R., & Schulz, F. (2017) · Nature Methods · doi:10.1038/nmeth.4469 · Cited by 177
Microfluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
New Technologies for Studying Biofilms
Franklin, M. J., Chang, C., Akiyama, T., & Bothner, B. (2015) · Microbial Biofilms · doi:10.1128/9781555817466.ch1 · Cited by 11
Metadata
- Authors
- Leung, K., Zahn, H., Leaver, T., Konwar, K. M., Hanson, N. W., Pagé, A. P., Lo, C.-C., Chain, P. S., Hallam, S. J., & Hansen, C. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-04-30
- Volume
- 109
- Issue
- 20
- Pages
- 7665-7670
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2105776288
- Cited by
- 243
- References
- 36
- FWCI
- 13.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.