Heart wall myofibers are arranged in minimal surfaces to optimize organ function
Open accessThe DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.
Abstract
Heart wall myofibers wind as helices around the ventricles, strengthening them in a manner analogous to the reinforcement of concrete cylindrical columns by spiral steel cables [Richart FE, et al. (1929) Univ of Illinois, Eng Exp Stn Bull 190]. A multitude of such fibers, arranged smoothly and regularly, contract and relax as an integrated functional unit as the heart beats. To orchestrate this motion, fiber tangling must be avoided and pumping should be efficient. Current models of myofiber orientation across the heart wall suggest groupings into sheets or bands, but the precise geometry of bundles of myofibers is unknown. Here we show that this arrangement takes the form of a special minimal surface, the generalized helicoid [Blair DE, Vanstone JR (1978) Minimal Submanifolds and Geodesics 13–16], closing the gap between individual myofibers and their collective wall structure. The model holds across species, with a smooth variation in its three curvature parameters within the myocardial wall providing tight fits to diffusion magnetic resonance images from the rat, the dog, and the human. Mathematically it explains how myofibers are bundled in the heart wall while economizing fiber length and optimizing ventricular ejection volume as they contract. The generalized helicoid provides a unique foundation for analyzing the fibrous composite of the heart wall and should therefore find applications in heart tissue engineering and in the study of heart muscle diseases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The myocardial ECM is fibrillar, anisotropic, and provides nanotopographical cues that guide cardiomyocyte alignment and assembly44, ultimately forming a helicoid structure that optimizes ejection fraction during ventricular contraction45.”
From A tissue-engineered scale model of the heart ventricle (2018) · cites this paper as [45]
Citations
Cites
Fisher, R. (1953) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1953.0064 · Cited by 5,563
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Osserman, R. (1969) · CERN Document Server (European Organization for Nuclear Research) · Cited by 998
LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h571 · Cited by 842
Twisted fibrous arrangements in biological materials and cholesteric mesophases
Bouligand, Y. (1972) · Tissue and Cell · doi:10.1016/s0040-8166(72)80042-9 · Cited by 818
Distance transformations in arbitrary dimensions
Borgefors, G. (1984) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(84)90035-5 · Cited by 779
Mathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Mathematical aspects of heart physiology
Peskin, C. S. (1975) · Courant Institute of Mathematical Sciences, New York University eBooks · Cited by 614
Diffusion MRI: Theory, methods, and applications
Jones, D. K. (2011) · Cited by 444
Research works printed but not linked: 2
- DE Blair, JR Vanstone, A generalization of the helicoid. Minimal Submanifolds and Geodesics (Kaigai Publ, Tokyo), pp. 13–16 (1978).
- JJ Nitsche Lectures on Minimal Surfaces: Volume 1, Introduction, Fundamentals, Geometry and Basic Boundary Value Problems (Cambridge Univ Press, Cambridge, UK, 1989).
Cited by
The Relationship Between the Right Ventricle and its Load in Pulmonary Hypertension
Vonk Noordegraaf, A., Westerhof, B. E., & Westerhof, N. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.047 · Cited by 780
“New techniques under development to measure fiber orientation in the ventricular wall (56) and to derive wall stiffness, such as ultrasound-based elastography (57) are promising, but have not yet been applied in the context of PH.”
MethodGuidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
A tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
Papadacci, C., Finel, V., Provost, J., Villemain, O., Bruneval, P., Gennisson, J., Tanter, M., Fink, M., & Pernot, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00946-7 · Cited by 108
PDE-Based Group Equivariant Convolutional Neural Networks
Smets, B., Portegies, J., Bekkers, E. J., & Duits, R. (2022) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-022-01114-x · Cited by 83
Thomas, S., Lagzi, I., Molnár, F., & Ràcz, Z. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.078303 · Cited by 57
3D Fiber Orientation in Atherosclerotic Carotid Plaques
Akyildiz, A. C., Chai, C.-K., Oomens, C. W. J., van der Lugt, A., Baaijens, F. F., Strijkers, G. J., & Gijsen, F. J. H. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2017.08.003 · Cited by 51
Self-citationSmall animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Self-citationImaging technologies for cardiac fiber and heart failure: a review
Watson, S. R., Dormer, J. D., & Fei, B. (2018) · Heart Failure Reviews · doi:10.1007/s10741-018-9684-1 · Cited by 37
Simulating cardiac fluid dynamics in the human heart
Davey, M., Puelz, C., Rossi, S., Smith, M. A., Wells, D., Sturgeon, G. M., Segars, W. P., Vavalle, J. P., Peskin, C. S., & Griffith, B. E. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae392 · Cited by 41
“Current studies vary widely in both methodology and scale, from wet-lab experiments of cell function to analytic characterization of muscle fiber orientation (2, 3).”
BackgroundAngeli, S. I., Befera, N. T., Peyrat, J., Calabrese, E., Johnson, G. A., & Constantinides, C. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0077-x · Cited by 29
“helicoids) as an innate compensatory mechanism to optimize organ function and contractile ejection [6].”
BackgroundA Bayesian framework for joint morphometry of surface and curve meshes in multi-object complexes
Gori, P., Colliot, O., Marrakchi‐Kacem, L., Worbe, Y., Poupon, C., Hartmann, A., Ayache, N., & Durrleman, S. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.08.011 · Cited by 37
Locally Adaptive Frames in the Roto-Translation Group and Their Applications in Medical Imaging
Duits, R., Janssen, M. H. J., Hannink, J., & Sanguinetti, G. (2016) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-016-0641-0 · Cited by 28
“Based on co-helicity principles, similar spirals have 127 been used in neuroimaging applications [61] or for modeling 128 heart fibers [62].”
MethodFusion of white and gray matter geometry: A framework for investigating brain development
Savadjiev, P., Yogesh Rathi, A., Sylvain Bouix, A., Smith, A. R., Schultz, R. T., Verma, R., & Westin, C. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.06.013 · Cited by 27
“Furthermore, while the Frenet frame directions are sufficient to capture the geometry for slowly varying sets of curves, such as the cardiac myofibers in [48], brain white matter tracts can change their orientation quite rapidly, even within a local neighborhood.”
BackgroundInfluentialSelf-citationWill the real ventricular architecture please stand up?
Hoffman, J. I. E. (2017) · Physiological Reports · doi:10.14814/phy2.13404 · Cited by 27
Qin, X., & Fei, B. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3907 · Cited by 21
“It has been reported that the general orientations can be divided into different layers, with the myofiber orientations continuously changing along the depth (Savadjiev et al 2012).”
InfluentialDileep, D., Syed, T. A., Sloan, T. F. W., Dhandapany, P. S., Kaleem Siddiqi, A., & Sirajuddin, M. (2023) · The EMBO Journal · doi:10.15252/embj.2022113288 · Cited by 25
“…the present models of heart wall cardiomyocyte geometry in use for cardiovascular research are largely derived from millimeter resolution diffusion-tensor magnetic resonance imaging (DT-MRI; Peskin, 1989; Horowitz et al , 1993; Helm et al , 2005; Gilbert et al , 2007; Savadjiev et al , 2012).”
InfluentialMaurer-Cartan Forms for Fields on Surfaces: Application to Heart Fiber Geometry
Piuze, E., Jon Sporring, A., & Kaleem Siddiqi, A. (2015) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2015.2408352 · Cited by 18
“Following [12] and conventional cardiac spatial analysis, we use a model for the frame field which is based on an estimate of the local normal to the heart wall.”
BackgroundMethodInfluentialSelf-citationAssessment of Myofiber Orientation in High Resolution Phase-Contrast CT Images
Baličević, V., Lončarić, S., Cárdenes, R., González-Tendero, A., Paun, B., Crispi, F., Butakoff, C., & Bijnens, B. H. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-20309-6_13 · Cited by 18
“Most commonly it is the diffusion tensor magnetic resonance imaging (DT-MRI) [5–8], which employs the anisotropic water diffusion property of the tissue to determine its orientation.”
BackgroundThe Right Ventricle in Pulmonary Hypertension
Wessels, J. N., Celant, L. R., de Man, F. S., & Noordegraaf, A. V. (2023) · Seminars in Respiratory and Critical Care Medicine · doi:10.1055/s-0043-1770117 · Cited by 16
The Other Side of the Fascia: Visceral Fascia, Part 2
Bordoni, B., Simonelli, M., & Morabito, B. (2019) · Cureus · doi:10.7759/cureus.4632 · Cited by 19
Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound
Qin, X., Wang, S., Shen, M., Zhang, X.-D., Wagner, M. B., & Fei, B. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043821 · Cited by 14
“These parameters can improve or even change cardiac diagnosis or quantitative modeling [7].”
BackgroundInfluence of fiber connectivity in simulations of cardiac biomechanics
Gil, D., Aris, R., Borràs, A., Esmitt Ramírez, J., Sebastián, R., & Vázquez, M. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1849-9 · Cited by 16
Geodesic Tracking via New Data-Driven Connections of Cartan Type for Vascular Tree Tracking
van den Berg, N. J., Smets, B., Pai, G., Mirebeau, J., & Duits, R. (2024) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-023-01170-x · Cited by 13
Adaptation of myocardial twist in the remodelled athlete's heart is not related to cardiac output
Cooke, S., Samuel, T. J., Cooper, S., & Stöhr, E. J. (2018) · Experimental Physiology · doi:10.1113/ep087165 · Cited by 13
“, 2017), and optimised in its underlying structure to facilitate the most efficient (and therefore stress-minimized) ejection (Savadjiev et al., 2012), then the failure to augment cardiac output during exercise stress may in fact be a protective mechanism to avoid further myofibre stress caused by additional shortenin…”
BackgroundWhat a Difference in Biomechanics Cardiac Fiber Makes
Gil, D., Borràs, A., Arís, R., Vázquez, M., Lafortune, P., Houzeaux, G., Aguado‐Sierra, J., Ballester, M., Li, C., & Carreras, F. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-36961-2_29 · Cited by 12
Knowledge Based Versus Data Based
Savadjiev, P., Reinhold, C., Martín, D. R., & Forghani, R. (2020) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2020.06.002 · Cited by 15
Self-citationWang, Y., Cai, W., Wang, L., & Xia, R. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.12.007 · Cited by 12
“The focal defects of myocardial tensors on the endocardium are indicative of initial disability of thewall torsion in the infarcted regions as thewall torsion usually depends on the cross-movements of the multi-orientation tensors [16,27,28].”
BackgroundMethodConduction in the Heart Wall: Helicoidal Fibers Minimize Diffusion Bias
Aumentado‐Armstrong, T., Kadivar, A., Savadjiev, P., Zucker, S. W., & Siddiqi, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-25334-7 · Cited by 13
Self-citationAtlases of Cardiac Fiber Differential Geometry
Piuze, E., Lombaert, H., Jon Sporring, A., Strijkers, G. J., Bakermans, A. J., & Kaleem Siddiqi, A. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38899-6_52 · Cited by 10
“In contrast with previous work, where the GHM parameter vector K was estimated in coarse discrete bins using relaxation labeling methods [12], a continuous approach using a Nelder-Mead optimization scheme is used.”
BackgroundMethodResultSelf-citationUV laser-processed microstructure for building biohybrid actuators with anisotropic movement
Mita, H., Mizuno, Y., Tanaka, H., & Fujie, T. (2024) · Biofabrication · doi:10.1088/1758-5090/ad2080 · Cited by 10
Nagler, A., Bertoglio, C., Stoeck, C. T., Kozerke, S., & Wall, W. A. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.03.005 · Cited by 9
Structure Tensors for Dispersed Fibers in Soft Materials
Kalhöfer-Köchling, M., Bodenschatz, E., & Wang, Y. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.13.064039 · Cited by 9
Joint Statistics on Cardiac Shape and Fiber Architecture
Lombaert, H., & Peyrat, J. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40763-5_61 · Cited by 8
Stereo, Shading, and Surfaces: Curvature Constraints Couple Neural Computations
Zucker, S. W. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2314723 · Cited by 10
“Another geometrically related application is to the arrangement of myofibers in the heart wall [107]; see Fig.”
BackgroundSelf-citationDTI template-based estimation of cardiac fiber orientations from 3D ultrasound
Qin, X., & Fei, B. (2015) · Medical Physics · doi:10.1118/1.4921121 · Cited by 7
The Hessian of Axially Symmetric Functions on SE(3) and Application in 3D Image Analysis
Janssen, M. H. J., Haije, T. C. J. D., Martin, F. C., Bekkers, E. J., & Duits, R. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-58771-4_51 · Cited by 7
“Local curve optimization that accounts for local curvature via spiral fits has been proposed in [11], where a more complex model of neighboring curves is fitted.”
BackgroundMoving Frames for Heart Fiber Geometry
Piuze, E., Jon Sporring, A., & Kaleem Siddiqi, A. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38868-2_44 · Cited by 7
“[12] have recently obtained a promising characterization of the collective geometrical variation of cardiac fibers, using a method derived from texture flow analysis [11].”
BackgroundMethodSelf-citationOsteopathic Palpation of the Heart
Bordoni, B., & Escher, A. R. (2021) · Cureus · doi:10.7759/cureus.14187 · Cited by 6
“Tractography of the heart demonstrates a helical structure but with variable myocyte vectors: in the subendocardial layer, the fibers are oriented longitudinally and obliquely, from the base towards the apex; in the intermediate layer, they are oriented in a circular direction while the sub-layer - epicardial is forme…”
BackgroundExploring cardiac form and function: A length‐scale computational biology approach
Sherman, W. F., & Grosberg, A. (2019) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1470 · Cited by 8
“In addition to the modeling techniques discussed, several models use an optimization approach when describing the dynamics at the spatial scale of interest (Savadjiev et al., 2012; Washio et al., 2016).”
MethodAnisotropy Across Fields and Scales
Özarslan, E., Schultz, T., Zhang, E., & Fuster, A. (2021) · Mathematics and visualization · doi:10.1007/978-3-030-56215-1 · Cited by 7
Wang, Y., Cai, W., Wang, L., Xia, R., Chen, W., Zheng, J., & Gao, F. (2016) · Korean Journal of Radiology · doi:10.3348/kjr.2016.17.5.725 · Cited by 6
Riemann-DTI Geodesic Tractography Revisited
Florack, L. M. J., Sengers, R., Meesters, S., Smolders, L., & Fuster, A. (2021) · Mathematics and visualization · doi:10.1007/978-3-030-56215-1_11 · Cited by 6
Marchesseau, S., Sermesant, M., Billet, F., Delingette, H., & Ayache, N. (2015) · Wiley eBooks · doi:10.1002/9781118574362.ch9 · Cited by 5
Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts
Qin, X., Wang, S., Shen, M., Zhang, X., Lerakis, S., Wagner, M. B., & Fei, B. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082317 · Cited by 3
“-> 2D registration slice by slice Best > Refine slice by transforming the volume Deform 2D target US image to match the 2D slices from the 3D template US volume Inverse v deformation TransformDTl Fibers of the ofthe slice inversely target image _> Currently, MR-DTI has been utilized to extract the fiber orientations o…”
MethodCardiac Fiber Unfolding by Semidefinite Programming
Li, H., Robini, M. C., Yang, F., Magnin, I. E., & Zhu, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2360797 · Cited by 3
Nano‐ and Microstructured ECM and Biomimetic Scaffolds for Cardiac Tissue Engineering
Jallerat, Q., Szymanski, J. M., & Feinberg, A. W. (2014) · Wiley eBooks · doi:10.1002/9781118843499.ch12 · Cited by 3
Cartan Frame Analysis of Hearts with Infarcts
Goblot, D., Pop, M., & Kaleem Siddiqi, A. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-52718-5_10 · Cited by 2
The Pathobiology of Chronic Right Ventricular Failure
Voelkel, N. F., Gomez‐Arroyo, J. G., Abbate, A., & Bogaard, H. J. (2014) · Respiratory medicine · doi:10.1007/978-1-4939-1065-6_13 · Cited by 1
Cardiac Fiber Inpainting Using Cartan Forms
Piuze, E., Lombaert, H., Jon Sporring, A., & Kaleem Siddiqi, A. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40763-5_63 · Cited by 1
Self-citationMoving Frames for Heart Fiber Reconstruction
Piuze, E., Jon Sporring, A., & Kaleem Siddiqi, A. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-19992-4_41 · Cited by 1
Self-citationGori, P. (2016) · theses.fr (ABES) · doi:10.70675/12ba1bd7zd7edz4a65z838fzc395b0808541 · Cited by 1
Connection Forms for Beating the Heart
Mensch, A., Piuze, E., Lehnert, L., Bakermans, A. J., Jon Sporring, A., Strijkers, G. J., & Kaleem Siddiqi, A. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-14678-2_9
Self-citationMitochondrial Remodeling During Physiological Cardiac Hypertrophy in the Burmese Python
Killian, H. R., Meador, K. G., Proctor, D. M., Gressman, K. M., Nuanes, V. A., Dansereau, O., Shattuck, K. L., Gallagher, C. K., Santos, K. A., Thaden, T. D., et al. (2015)
Estimating Sheets in the Heart Wall
Syed, T. A., Samari, B., & Kaleem Siddiqi, A. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-12029-0_1
High-Resolution Whole-Heart Imaging and Modeling for Studying Cardiac Arrhythmia
Pashakhanloo, F. (2016) · Cited by 1
Minimizing Non-holonomicity: Finding Sheets in Fibrous Structures
Samari, B., Syed, T. A., & Kaleem Siddiqi, A. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-20351-1_14
Thiriet, M. (2012) · Biomathematical and biomechanical modeling of the circulatory and ventilatory systems · doi:10.1007/978-1-4614-5966-8_5
Faculty Opinions recommendation of A tissue-engineered scale model of the heart ventricle.
Radisic, M. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.733680169.793554004
Faculty Opinions recommendation of A tissue-engineered scale model of the heart ventricle.
Truskey, G. A. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.733680169.793549351
Metadata
- Authors
- Savadjiev, P., Strijkers, G. J., Bakermans, A. J., Piuze, E., Zucker, S. W., & Siddiqi, K.
- Affiliations
- Brigham and Women's Hospital (US)
- Eindhoven University of Technology (NL)
- McGill University (CA)
- Yale University (US)
- School of Computer Science and Centre for Intelligent Machines, McGill University, Montréal, Canada H3A 2A7; and
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2012-05-29
- Volume
- 109
- Issue
- 24
- Pages
- 9248-9253
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3386057
- OpenAlex
- W2169776346
- Cited by
- 62
- References
- 40
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 8 · 2017: 7 · 2016: 5 · 2015: 10 · 2014: 9 · 2013: 6 · 2012: 1
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Update notices
- correction (2012-11-12)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
- Keywords
- minimal surfaces, cardiac tissue engineering, cardiomyopathy
- MeSH terms
- Animals, Dogs, Heart, Humans, Magnetic Resonance Imaging, Myocardial Contraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.