The DOI matches its Crossref record.
Laminar structure of the heart: ventricular myocyte arrangement and connective tissue architecture in the dog
Abstract
We have studied the three-dimensional arrangement of ventricular muscle cells and the associated extracellular connective tissue matrix in dog hearts. Four hearts were potassium-arrested, excised, and perfusion-fixed at zero transmural pressure. Full-thickness segments were cut from the right and left ventricular walls at a series of precisely located sites. Morphology was visualized macroscopically and with scanning electron microscopy in 1) transmural planes of section and 2) planes tangential to the epicardial surface. The appearance of all specimens was consistent with an ordered laminar arrangement of myocytes with extensive cleavage planes between muscle layers. These planes ran radially from endocardium toward epicardium in transmural section and coincided with the local muscle fiber orientation in tangential section. Stereological techniques were used to quantify aspects of this organization. There was no consistent variation in the cellular organization of muscle layers (48.4 +/- 20.4 microns thick and 4 +/- 2 myocytes across) transmurally or in different ventricular regions (23 sites in 6 segments), but there was significant transmural variation in the coupling between adjacent layers. The number of branches between layers decreased twofold from subepicardium to midwall, whereas the length distribution of perimysial collagen fibers connecting muscle layers was greatest in the midwall. We conclude that ventricular myocardium is not a uniformly branching continuum but a laminar hierarchy in which it is possible to identify three axes of material symmetry at any point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Holzapfel, G. A., & Ogden, R. W. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0091 · Cited by 836
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557
Laminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium
Costa, K. D., Takayama, Y., McCulloch, A. D., & Covell, J. W. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h595 · Cited by 313
Metadata
- Authors
- LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1995-08-01
- Volume
- 269
- Issue
- 2
- Pages
- H571-H582
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1550726172
- Cited by
- 842
- References
- 0
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laminar structure of the heart: ventricular myocyte arrangement and connective tissue architecture in the dog. https://app.cochat.ai/papers/10.1152/ajpheart.1995.269.2.h571
- The paper
- LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995). Laminar structure of the heart: ventricular myocyte arrangement and connective tissue architecture in the dog. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1995.269.2.h571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.