The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise
Open accessAbstract
Single particle cryo-electron microscopy is currently poised to produce high-resolution structures of many biological assemblies, but several pitfalls can trap the unwary. This critique highlights one problem that is particularly relevant when smaller structures are being studied. It is known as “Einstein from noise,” in which the experimenter honestly believes they have recorded images of their particles, whereas in reality, most if not all of their data consist of pure noise. Selection of particles using cross-correlation methods can then lead to 3D maps that resemble the model used in the initial selection and provide the illusion of progress. Suggestions are given about how to circumvent the problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Self-citation
Cited by
cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination
Punjani, A., Rubinstein, J. L., Fleet, D. J., & Brubaker, M. A. (2017) · Nature Methods · doi:10.1038/nmeth.4169 · Cited by 11,626
Positive-unlabeled convolutional neural networks for particle picking in cryo-electron micrographs
Bepler, T., Morin, A., Rapp, M., Brasch, J., Shapiro, L., Noble, A. J., & Berger, B. (2019) · Nature Methods · doi:10.1038/s41592-019-0575-8 · Cited by 1,606
Real-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
SPHIRE-crYOLO is a fast and accurate fully automated particle picker for cryo-EM
Wagner, T., Merino, F., Stabrin, M., Moriya, T., Antoni, C., Apelbaum, A., Hagel, P., Sitsel, O., Raisch, T., Prumbaum, D., et al. (2019) · Communications Biology · doi:10.1038/s42003-019-0437-z · Cited by 1,282
cisTEM, user-friendly software for single-particle image processing
Grant, T., Rohou, A., & Grigorieff, N. (2018) · eLife · doi:10.7554/elife.35383 · Cited by 865
Metadata
- Authors
- Henderson, R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2013-10-08
- Volume
- 110
- Issue
- 45
- Pages
- 18037-18041
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2077874772
- Cited by
- 224
- References
- 1
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise. https://app.cochat.ai/papers/10.1073/pnas.1314449110
- The paper
- Henderson, R. (2013). Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1314449110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.