The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Structure of β-galactosidase at 3.2-Å resolution obtained by cryo-electron microscopy
Open accessAbstract
Significance: Atomic resolution models for proteins and protein complexes are usually obtained using X-ray crystallography or NMR spectroscopy, and in selected instances, by cryo-electron microscopy (cryo-EM) of ordered protein assemblies. The vast majority of high-resolution structures obtained using cryo-EM have been typically restricted to large, well-ordered entities such as helical or icosahedral assemblies or two-dimensional crystals. We show here that emerging methods in single-particle cryo-EM now allow structure determination at near-atomic resolution, even for much smaller protein complexes with low symmetry, by determining the structure of the 465-kDa enzyme β-galactosidase. In addition, by quantitative comparison of density maps obtained at different electron dosages, we demonstrate preferential sensitivity of residues such as Asp and Glu to damage upon irradiation with electrons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Cited by
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy
Zheng, S. Q., Palovcak, E., Armache, J.-P., Verba, K. A., Cheng, Y., & Agard, D. A. (2017) · Nature Methods · doi:10.1038/nmeth.4193 · Cited by 7,777
CTFFIND4: Fast and accurate defocus estimation from electron micrographs
Rohou, A., & Grigorieff, N. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.08.008 · Cited by 4,913
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
cisTEM, user-friendly software for single-particle image processing
Grant, T., Rohou, A., & Grigorieff, N. (2018) · eLife · doi:10.7554/elife.35383 · Cited by 865
Grant, T., & Grigorieff, N. (2015) · eLife · doi:10.7554/elife.06980 · Cited by 826
Structure of the mechanically activated ion channel Piezo1
Saotome, K., Murthy, S. E., Kefauver, J. M., Whitwam, T., Patapoutian, A., & Ward, A. B. (2018) · Nature · doi:10.1038/nature25453 · Cited by 649
Single-Particle Cryo-EM at Crystallographic Resolution
Cheng, Y. (2015) · Cell · doi:10.1016/j.cell.2015.03.049 · Cited by 581
Breaking Cryo-EM Resolution Barriers to Facilitate Drug Discovery
Merk, A., Bartesaghi, A., Banerjee, S., Falconieri, V., Rao, P., Davis, M. I., Pragani, R., Boxer, M. B., Earl, L. A., Milne, J. L. S., et al. (2016) · Cell · doi:10.1016/j.cell.2016.05.040 · Cited by 504
Self-citationAutomated structure refinement of macromolecular assemblies from cryo-EM maps using Rosetta
Wang, R. Y.-R., Song, Y., Barad, B. A., Cheng, Y., Fraser, J. S., & DiMaio, F. (2016) · eLife · doi:10.7554/elife.17219 · Cited by 457
Structure and Mechanisms of F-Type ATP Synthases
Kühlbrandt, W. (2019) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-013118-110903 · Cited by 444
2.2 Å resolution cryo-EM structure of β-galactosidase in complex with a cell-permeant inhibitor
Bartesaghi, A., Merk, A., Banerjee, S., Matthies, D., Wu, X., Milne, J. L. S., & Subramaniam, S. (2015) · Science · doi:10.1126/science.aab1576 · Cited by 438
Self-citationStructure, mechanism, and regulation of the chloroplast ATP synthase
Hahn, A., Vonck, J., Mills, D. J., Meier, T., & Kühlbrandt, W. (2018) · Science · doi:10.1126/science.aat4318 · Cited by 420
Cryo-EM: A Unique Tool for the Visualization of Macromolecular Complexity
Nogales, E., & Scheres, S. H. W. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.019 · Cited by 378
Structure of the E. coli ribosome–EF-Tu complex at <3 Å resolution by Cs-corrected cryo-EM
Fischer, N., Neumann, P., Konevega, A. L., Bock, L. V., Ficner, R., Rodnina, M. V., & Stark, H. (2015) · Nature · doi:10.1038/nature14275 · Cited by 362
Structure of the human TRPM4 ion channel in a lipid nanodisc
Autzen, H. E., Myasnikov, A. G., Campbell, M. G., Asarnow, D., Julius, D., & Cheng, Y. (2018) · Science · doi:10.1126/science.aar4510 · Cited by 265
Atomic model for the dimeric F O region of mitochondrial ATP synthase
Guo, H., Bueler, S. A., & Rubinstein, J. L. (2017) · Science · doi:10.1126/science.aao4815 · Cited by 225
Electron crystallography of ultrathin 3D protein crystals: atomic model with charges
Yonekura, K., Kato, K., Ogasawara, M., Tomita, M., & Toyoshima, C. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500724112 · Cited by 190
Liu, S., Xia, X., Zhen, J., Li, Z., & Zhou, Z. H. (2022) · Cell Discovery · doi:10.1038/s41421-022-00487-y · Cited by 29
End-to-end cryo-EM complex structure determination with high accuracy and ultra-fast speed
Wang, J., Tan, C., Gao, Z., Zhang, G., Zhang, Y., & Li, S. Z. (2025) · Nature Machine Intelligence · doi:10.1038/s42256-025-01056-0 · Cited by 8
Borges, R. J., Salvador, G. H. M., Pimenta, D. C., dos Santos, L. D., Fontes, M. R. M., & Usón, I. (2022) · Nucleic Acids Research · doi:10.1093/nar/gkac029 · Cited by 5
Metadata
- Authors
- Bartesaghi, A., Matthies, D., Banerjee, S., Merk, A., & Subramaniam, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-07-28
- Volume
- 111
- Issue
- 32
- Pages
- 11709-11714
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1980885982
- Cited by
- 190
- References
- 1
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.