The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Biodegradable Piezoelectric Force Sensor
Open accessAbstract
Significance: Measuring physiological pressures such as lung pressure, brain pressure, eye pressure, etc. is important for monitoring health status, preventing the buildup of dangerous internal forces in impaired organs, and enabling novel approaches of using mechanical stimulation for tissue regeneration. Pressure sensors are often implanted and directly integrated with soft biological systems. Therefore, the devices should be flexible and at the same time biodegradable to avoid invasive removal surgery. Here, we present the study and processing of a biodegradable polymer which can convert mechanical force to electricity, and employ the polymer to develop a biocompatible implanted force sensor. The sensor, relying solely on common medical materials, can monitor important biological forces and eventually self-vanish, causing no harm to the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical ventilation guided by esophageal pressure in acute lung injury.
Talmor, D., Sarge, T., Malhotra, A., O'Donnell, C. R., Ritz, R., Lisbon, A., Novack, V., & Loring, S. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708638 · Cited by 1,149
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617 · cited 1×
“Recently, triboelectric sensors fabricated with biodegradable polymers have been reported with the exciting ability for in vivo energy harvesting (6).”
BackgroundQi, Y., Kim, J., Nguyen, T. D., Lisko, B., Purohit, P. K., & McAlpine, M. C. (2011) · Nano Letters · doi:10.1021/nl104412b · Cited by 516 · cited 1×
“Piezoelectricity is a phenomenon which allows materials to convert deformation into electricity and vice versa (9).”
BackgroundSelf-citationDesign and Development of Three-Dimensional Scaffolds for Tissue Engineering
Liu, C., Xia, Z., & Czernuszka, J. T. (2007) · Chemical Engineering Research and Design · doi:10.1205/cherd06196 · Cited by 483
Zi, Y., Lin, L., Wang, J., Wang, S., Chen, J., Fan, X., Yang, P., Yi, F., & Wang, Z. L. (2015) · Advanced Materials · doi:10.1002/adma.201500121 · Cited by 482 · cited 1×
“Friction-induced triboelectric charges, while ideal for energy harvesting and some force-detecting applications, are often susceptible to noise from motion of the sensor (7), variation of force response due to the delay of charge dissipation in the sensor (8), and a limitation of miniaturization due to the requirement…”
BackgroundDrug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
Bos, R. R. M., Boering, G., Rozema, F. R., & Leenslag, J. W. (1987) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(87)90194-7 · Cited by 324
Minary-Jolandan, M., & Yu, M.-F. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/8/085706 · Cited by 235
Diaphragm Activation during Exercise in Chronic Obstructive Pulmonary Disease
SINDERBY, C., SPAHIJA, J., BECK, J., KAMINSKI, D., YAN, S., COMTOIS, N., & SLIWINSKI, P. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2007033 · Cited by 201 · cited 1×
“sensor for monitoring respiratory disorders caused by obstructive pulmonary diseases (36).”
BackgroundPiezoelectric nanoribbons for monitoring cellular deformations
Nguyen, T. D., Deshmukh, N., Nagarah, J. M., Kramer, T., Purohit, P. K., Berry, M. J., & McAlpine, M. C. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.112 · Cited by 188
Self-citationGuo, Q., Cao, G., & Shen, I. Y. (2013) · Journal of vibration and acoustics · doi:10.1115/1.4006881 · Cited by 151
Dominant β-Form of Poly( l -lactic acid) Obtained Directly from Melt under Shear and Pressure Fields
Ru, J., Yang, S.-G., Zhou, D., Yin, H., Lei, J., & Li, Z. (2016) · Macromolecules · doi:10.1021/acs.macromol.6b00595 · Cited by 115
Xu, H., Teng, C., & Yu, M. (2006) · Polymer · doi:10.1016/j.polymer.2006.03.090 · Cited by 113 · cited 1×
“The processed PLLA often exhibits three crystalline orientations of [111], [200], and [110] (29), yet once the films reach a DR of 3.”
BackgroundMonitoring of Vital Signs for Long-Term Survival of Mice under Anesthesia: FIGURE 1.Preprint
Ewald, A. J., Werb, Z., & Egeblad, M. (2011) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot5563 · Cited by 109
Fukada, E. (1998) · Japanese Journal of Applied Physics · doi:10.1143/jjap.37.2775 · Cited by 95
Pressure-Sensitive Touch Panel Based on Piezoelectric Poly(L-lactic acid) Film
Ando, M., Kawamura, H., Kitada, H., Sekimoto, Y., Inoue, T., & Tajitsu, Y. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.09kd17 · Cited by 90
High piezoelectric performance of poly(lactic acid) film manufactured by solid-state extrusion
Yoshida, M., Onogi, T., Onishi, K., Inagaki, T., & Tajitsu, Y. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.09pc02 · Cited by 78
Tajitsu, Y., Kawai, S., KANESAKI, M., Date, M., & Fukada, E. (2004) · Ferroelectrics · doi:10.1080/00150190490460885 · Cited by 60
Wafer-Scale Nanopatterning and Translation into High-Performance Piezoelectric Nanowires
Nguyen, T. D., Nagarah, J. M., Qi, Y. P., Nonnenmann, S. S., Morozov, A. V., Li, S., Arnold, C. B., & McAlpine, M. C. (2010) · Nano Letters · doi:10.1021/nl102619c · Cited by 54
Self-citationIntracranial Pressure Monitoring in Acute Liver Failure: Institutional Case Series
Maloney, P. R., Mallory, G. W., Atkinson, J. L. D., Wijdicks, E. F. M., Rabinstein, A. A., & Gompel, J. J. V. (2016) · Neurocritical Care · doi:10.1007/s12028-016-0261-y · Cited by 30
Development of a Smart Pump for Monitoring and Controlling Intraocular Pressure
Bello, S. A., Malavade, S. S., & Passaglia, C. L. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1735-y · Cited by 25
Stretchable Piezoelectric Nanoribbons for Biocompatible Energy Harvesting
Qi, Y. P., Nguyen, T. D., Purohit, P. K., & McAlpine, M. C. (2012) · Wiley eBooks · doi:10.1002/9783527646982.ch5 · Cited by 19
Self-citationNguyen, T. D., & Timko, B. P. (2017) · Wiley eBooks · doi:10.1002/9783527689934.ch21 · Cited by 4
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationDisposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilies, H., & Nguyen, T. D. (2019) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 865
Self-citationFunctional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Glycine–Chitosan-Based Flexible Biodegradable Piezoelectric Pressure Sensor
Hosseini, E. S., Manjakkal, L., Shakthivel, D., & Dahiya, R. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b21052 · Cited by 476
Metadata
- Authors
- Curry, E. J., Ke, K., Chorsi, M. T., Wrobel, K. S., Miller, A. N., Patel, A., Kim, I., Feng, J., Yue, L., Wu, Q., Kuo, C.-L., Lo, K. W.-H., Laurencin, C. T., Ilies, H., Purohit, P. K., & Nguyen, T. D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-01-16
- Volume
- 115
- Issue
- 5
- Pages
- 909-914
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2783908655
- Cited by
- 431
- References
- 25
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.