The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Drug‐Eluting Bioabsorbable Magnesium Stent
Abstract
Current stent technology is based on the use of permanent implants that remain life long in the vessel wall, far beyond the time required for the prosthesis to accomplish its main goals of sealing dissection and preventing wall recoil. With the possibility to implant long vessel segments using antiproliferative drugs to prevent restenosis, the practice of transforming the coronary vessels into stiff tubes with a full metal jacket covering all side branches and being unable to adjust to the long‐term wall changes, including wall remodeling with lumen ectasia becomes a serious concern. In this article, we describe the first biodegradable stent based on a magnesium alloy that allows controlled corrosion with release to the vessel wall and the blood stream of a natural body component such as magnesium with beneficial antithrombotic, antiarrhythmic, and antiproliferative properties. We also discuss the animal experiments and the initial clinical applications in 20 patients with implants below the knee, with final results soon to be released, and the plans for the first coronary study. The results of these last two studies will indicate whether the absence of a permanent implant and the antiproliferative properties shown in animals are sufficient to prevent the restenotic process in humans or whether the prosthesis must be modified by adding the biodegradable coating with conventional antiproliferative drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127110.49192.72 · Cited by 759
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Holmes, D. R., Leon, M. B., Moses, J. W., Popma, J. J., Cutlip, D., Fitzgerald, P. J., Brown, C., Fischell, T., Wong, S. C., Midei, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112572.57794.22 · Cited by 515
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
VOGT, F. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.010 · Cited by 174
Smith, L. F., Heagerty, A. M., Bing, R. F., & Barnett, D. B. (1986) · International Journal of Cardiology · doi:10.1016/0167-5273(86)90239-1 · Cited by 136
CHRISTENSEN, C. W., Rieder, M. A., Silverstein, E. L., & Gencheff, N. E. (1995) · Circulation · doi:10.1161/01.cir.92.9.2617 · Cited by 104
Kemp, P. A., Gardiner, S. M., March, J. E., Rubin, P. C., & Bennett, T. M. (1999) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0702342 · Cited by 55
Cited by
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Self-citationCoronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Novel Magnesium Alloys Developed for Biomedical Application: A Review
Li, N., & Zheng, Y. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.02.005 · Cited by 744
Metadata
- Authors
- DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., ILSLEY, C., & ERBEL, R.
- Venue
- Journal of Interventional Cardiology
- Publisher
- Wiley
- Published
- 2004-11-11
- Volume
- 17
- Issue
- 6
- Pages
- 391-395
- ISSN
- 0896-4327 (ISSN-L)
- 1540-8183
- OpenAlex
- W2086490706
- Cited by
- 428
- References
- 12
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drug‐Eluting Bioabsorbable Magnesium Stent. https://app.cochat.ai/papers/10.1111/j.1540-8183.2004.04081.x
- The paper
- DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., ILSLEY, C., & ERBEL, R. (2004). Drug‐Eluting Bioabsorbable Magnesium Stent. Journal of Interventional Cardiology. https://doi.org/10.1111/j.1540-8183.2004.04081.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.