The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
FAST CARS: Engineering a laser spectroscopic technique for rapid identification of bacterial spores
Open accessAbstract
Airborne contaminants, e.g., bacterial spores, are usually analyzed by time-consuming microscopic, chemical, and biological assays. Current research into real-time laser spectroscopic detectors of such contaminants is based on e.g., resonance fluorescence. The present approach derives from recent experiments in which atoms and molecules are prepared by one (or more) coherent laser(s) and probed by another set of lasers. However, generating and using maximally coherent oscillation in macromolecules having an enormous number of degrees of freedom is challenging. In particular, the short dephasing times and rapid internal conversion rates are major obstacles. However, adiabatic fast passage techniques and the ability to generate combs of phase-coherent femtosecond pulses provide tools for the generation and utilization of maximal quantum coherence in large molecules and biopolymers. We call this technique FAST CARS (femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman spectroscopy), and the present article proposes and analyses ways in which it could be used to rapidly identify preselected molecules in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scully, M. O., & Zubairy, M. S. (1997) · doi:10.1017/cbo9780511813993 · Cited by 6,589
Self-citationObservation of coherent optical information storage in an atomic medium using halted light pulses
Liu, C., Dutton, Z., Behroozi, C. H., & Hau, L. V. (2001) · Nature · doi:10.1038/35054017 · Cited by 2,217
Storage of Light in Atomic Vapor
Phillips, D. F., Fleischhauer, A., Mair, A., Walsworth, R. L., & Lukin, M. D. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.783 · Cited by 2,042
Cited by
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
Physics and applications of atmospheric nonlinear optics and filamentation
Kasparian, J., & Wolf, J.-P. (2008) · Optics Express · doi:10.1364/oe.16.000466 · Cited by 361
Quantum Coherent Control for Nonlinear Spectroscopy and Microscopy
Silberberg, Y. (2009) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.040808.090427 · Cited by 270
Metadata
- Authors
- Scully, M. O., Kattawar, G. W., Lucht, R. P., Opatrný, T., Pilloff, H., Rebane, A., Sokolov, A. V., & Zubairy, M. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-08-13
- Volume
- 99
- Issue
- 17
- Pages
- 10994-11001
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2036149324
- Cited by
- 222
- References
- 3
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.