fMRI spectral signatures of sleep
Open accessThe DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
Sleep can be distinguished from wake by changes in brain electrical activity, typically assessed using electroencephalography (EEG). The hallmark of nonrapid-eye-movement (NREM) sleep is the shift from high-frequency, low-amplitude wake EEG to low-frequency, high-amplitude sleep EEG dominated by spindles and slow waves. Here we identified signatures of sleep in brain hemodynamic activity, using simultaneous functional MRI (fMRI) and EEG. We found that, at the transition from wake to sleep, fMRI blood oxygen level–dependent (BOLD) activity evolved from a mixed-frequency pattern to one dominated by two distinct oscillations: a low-frequency (<0.1 Hz) oscillation prominent in light sleep and correlated with the occurrence of spindles, and a high-frequency oscillation (>0.1 Hz) prominent in deep sleep and correlated with the occurrence of slow waves. The two oscillations were both detectable across the brain but exhibited distinct spatiotemporal patterns. During the falling-asleep process, the low-frequency oscillation first appeared in the thalamus, then the posterior cortex, and lastly the frontal cortex, while the high-frequency oscillation first appeared in the midbrain, then the frontal cortex, and lastly the posterior cortex. During the waking-up process, both oscillations disappeared first from the thalamus, then the frontal cortex, and lastly the posterior cortex. The BOLD oscillations provide local signatures of spindle and slow wave activity. They may be employed to monitor the regional occurrence of sleep or wakefulness, track which regions are the first to fall asleep or wake up at the wake–sleep transitions, and investigate local homeostatic sleep processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“the most reliable, task-independent EEG correlate of the conscious perception of visual, auditory, and somatosensory stimuli is an early negativity in the EEG evoked response (around 200 milliseconds or so) over the corresponding posterior sensory cortices107.”
From Consciousness and sleep (2024) · cites this paper as [107]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Brain stem reticular formation and activation of the EEG
Moruzzi, G., & Magoun, H. W. (1949) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(49)90219-9 · Cited by 4,307
Interplay between Cortical Spreading Depolarization and Seizures
Kramer, D. R., Fujii, T., Ohiorhenuan, I., & Liu, C. Y. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000452841 · Cited by 3,696
Steriade, M., Nunez, A., & Amzica, F. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-08-03252.1993 · Cited by 1,903
Huber, R., Felice Ghilardi, M., Massimini, M., & Tononi, G. (2004) · Nature · doi:10.1038/nature02663 · Cited by 1,854
Self-citationNatural waking and sleep states: a view from inside neocortical neurons
Steriade, M., Timofeev, I., & Grenier, F. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.5.1969 · Cited by 1,296 · cited 1×
“Slow waves are associated with the near-synchronous transitions in large populations of neurons between depolarized up states of intense firing and hyperpolarized down states of silence (1).”
BackgroundGrouping of brain rhythms in corticothalamic systems
Steriade, M. (2006) · Neuroscience · doi:10.1016/j.neuroscience.2005.10.029 · Cited by 1,296
The sleep slow oscillation as a traveling wave
Massimini, M., Huber, R., Ferrarelli, F., Hill, S., & Tononi, G. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.1318-04.2004 · Cited by 1,221 · cited 1×
“Intriguingly, the orbitofrontal cortex was found to have among the highest amplitudes of spindles (37); it is also involved in the origin and propagation of slow waves (40, 41).”
BackgroundSelf-citationNeural Circuitry of Wakefulness and Sleep
Scammell, T. E., Arrigoni, E., & Lipton, J. O. (2017) · Neuron · doi:10.1016/j.neuron.2017.01.014 · Cited by 966
Cited by
Tononi, G., Boly, M., & Cirelli, C. (2024) · Neuron · doi:10.1016/j.neuron.2024.04.011 · Cited by 70
Self-citation
Metadata
- Authors
- Song, C., Boly, M., Tagliazucchi, E., Laufs, H., & Tononi, G.
- Affiliations
- University of Wisconsin–Madison (US)
- Department of Psychiatry, University of Wisconsin–Madison, Madison, WI, 53719
- Adolfo Ibáñez University (CL)
- Goethe University Frankfurt (DE)
- Corresponding author
- Tononi, Giulio
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2022-07-21
- Volume
- 119
- Issue
- 30
- Pages
- e2016732119-e2016732119
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC9335231
- OpenAlex
- W4286492093
- Cited by
- 65
- References
- 83
- Citations by year
- 2026: 16 · 2025: 21 · 2024: 15 · 2023: 8 · 2022: 3
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
- Greater South Information System
- Funders
- Tiny Blue Dot Foundation (UW 133AAG3451)
- Wellcome Trust (209192/Z/17/Z)
- H2020 MSCA COFUND (663830-CU119)
- Bundesministerium für Bildung und Forschung (grant 01 EV 0703)
- LOEWE Neuronale Koordination Forschungsschwerpunkt Frankfurt (NeFF)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Sleep and Wakefulness Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- sleep, wake-sleep transition, NREM sleep, sleep spindles, slow waves, thalamus, frontal cortex, posterior cortex, midbrain, hemodynamic activity, sleep homeostasis
- MeSH terms
- Brain, Electroencephalography, Humans, Magnetic Resonance Imaging, Oxygen, Sleep, Wakefulness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: fMRI spectral signatures of sleep. https://app.cochat.ai/papers/10.1073/pnas.2016732119
- The paper
- Song, C., Boly, M., Tagliazucchi, E., Laufs, H., & Tononi, G. (2022). fMRI spectral signatures of sleep. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2016732119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.