The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
A high-speed atomic force microscope for studying biological macromolecules
Open accessAbstract
The atomic force microscope (AFM) is a powerful tool for imaging individual biological molecules attached to a substrate and placed in aqueous solution. At present, however, it is limited by the speed at which it can successively record highly resolved images. We sought to increase markedly the scan speed of the AFM, so that in the future it can be used to study the dynamic behavior of biomolecules. For this purpose, we have developed a high-speed scanner, free of resonant vibrations up to 60 kHz, small cantilevers with high resonance frequencies (450–650 kHz) and small spring constants (150–280 pN/nm), an objective-lens type of deflection detection device, and several electronic devices of wide bandwidth. Integration of these various devices has produced an AFM that can capture a 100 × 100 pixel 2 image within 80 ms and therefore can generate a movie consisting of many successive images (80-ms intervals) of a sample in aqueous solution. This is demonstrated by imaging myosin V molecules moving on mica (see http://www.s.kanazawa-u.ac.jp/phys/biophys/bmv_movie.htm ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Direct observation of single kinesin molecules moving along microtubules
Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T. (1996) · Nature · doi:10.1038/380451a0 · Cited by 711
Tapping mode atomic force microscopy in liquid
Putman, C. A. J., Van der Werf, K. O., De Grooth, B. G., Van Hulst, N. F., & Greve, J. (1994) · Applied Physics Letters · doi:10.1063/1.111597 · Cited by 545
Brain myosin-V is a two-headed unconventional myosin with motor activity
Cheney, R. (1993) · Cell · doi:10.1016/0092-8674(93)90675-g · Cited by 444
Escherichia coli RNA Polymerase Activity Observed Using Atomic Force Microscopy
Kasas, S., Thomson, N. H., Smith, B. L., Hansma, H. G., Zhu, X., Guthold, M., Bustamante, C., Kool, E. T., Kashlev, M., & Hansma, P. K. (1997) · Biochemistry · doi:10.1021/bi9624402 · Cited by 339
Studies of vibrating atomic force microscope cantilevers in liquid
Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K. (1996) · Journal of Applied Physics · doi:10.1063/1.363308 · Cited by 311
Probing protein-protein interactions in real time.
Viani, M. B., Pietrasanta, L. I., Thompson, J. B., Chand, A., Gebeshuber, I. C., Kindt, J. H., Richter, M., Hansma, H. G., & Hansma, P. K. (2000) · Nature Structural Biology · doi:10.1038/77936 · Cited by 284
Direct Observation of Processive Movement by Individual Myosin V Molecules
Sakamoto, T., Amitani, I., Yokota, E., & Ando, T. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.2819 · Cited by 185
Self-citationScanning force microscopy under aqueous solutions
Bustamante, C., Rivetti, C., & Keller, D. J. (1997) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(97)80082-6 · Cited by 183
Guthold, M., Bezanilla, M., Erie, D. A., Jenkins, B., Hansma, H. G., & Bustamante, C. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.26.12927 · Cited by 145
[1] Purification and assay of myosin V
Cheney, R. E. (1998) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(98)98003-x · Cited by 56
Cited by
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Detection and localization of single molecular recognition events using atomic force microscopy
Hinterdorfer, P., & Dufrêne, Y. F. (2006) · Nature Methods · doi:10.1038/nmeth871 · Cited by 1,055
Zhang, M., Cui, S. W., Cheung, P. C. K., & Wang, Q. (2007) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2006.07.013 · Cited by 989
Imaging modes of atomic force microscopy for application in molecular and cell biology
Dufrêne, Y. F., Ando, T., Garcia, R., Alsteens, D., Martinez-Martin, D., Engel, A., Gerber, C., & Müller, D. J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.45 · Cited by 945
Self-citationVideo imaging of walking myosin V by high-speed atomic force microscopy
Kodera, N., Yamamoto, D., Ishikawa, R., & Ando, T. (2010) · Nature · doi:10.1038/nature09450 · Cited by 881
Self-citation
Metadata
- Authors
- Ando, T., Kodera, N., Takai, E., Maruyama, D., Saito, K., & Toda, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-10-09
- Volume
- 98
- Issue
- 22
- Pages
- 12468-12472
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2167235502
- Cited by
- 1,102
- References
- 12
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.