The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers
Open accessAbstract
Optical sensors, with great potential to convert invisible bioanalytical response into readable information, have been envisioned as a powerful platform for biological analysis and early diagnosis of diseases. However, the current extraction of sensing data is basically processed via a series of complicated and time-consuming calibrations between samples and reference, which inevitably introduce extra measurement errors and potentially annihilate small intrinsic responses. Here, we have proposed and experimentally demonstrated a calibration-free sensor for achieving high-precision biosensing detection, based on an optically controlled terahertz (THz) ultrafast metasurface. Photoexcitation of the silicon bridge enables the resonant frequency shifting from 1.385 to 0.825 THz and reaches the maximal phase variation up to 50° at 1.11 THz. The typical environmental measurement errors are completely eliminated in theory by normalizing the Fourier-transformed transmission spectra between ultrashort time delays of 37 ps, resulting in an extremely robust sensing device for monitoring the cancerous process of gastric cells. We believe that our calibration-free sensors with high precision and robust advantages can extend their implementation to study ultrafast biological dynamics and may inspire considerable innovations in the field of medical devices with nondestructive detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109
Smyth, E. C., Nilsson, M., Grabsch, H. I., van Grieken, N. C., & Lordick, F. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31288-5 · Cited by 4,803
Electromagnetically Induced Transparency
Harris, S. E. (1997) · Physics Today · doi:10.1063/1.881806 · Cited by 4,035
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Materials for terahertz science and technology
Ferguson, B., & Zhang, X.-C. (2002) · Nature Materials · doi:10.1038/nmat708 · Cited by 3,284
Plasmon-Induced Transparency in Metamaterials
Zhang, S., Genov, D. A., Wang, Y., Liu, M., & Zhang, X. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.047401 · Cited by 2,430
Limonov, M. F., Rybin, M. V., Poddubny, A. N., & Kivshar, Y. S. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.142 · Cited by 1,974
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
Phase-change materials for non-volatile photonic applications
Wuttig, M., Bhaskaran, H., & Taubner, T. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.126 · Cited by 1,413
Imaging-based molecular barcoding with pixelated dielectric metasurfaces
Tittl, A., Leitis, A., Liu, M., Yesilkoy, F., Choi, D.-Y., Neshev, D. N., Kivshar, Y. S., & Altug, H. (2018) · Science · doi:10.1126/science.aas9768 · Cited by 1,329
Cited by
Zhang, Z., Wang, Z., Zhang, C., Yao, Z., Zhang, S., Wang, R., Tian, Z., Han, J., Chang, C., Lou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202308453 · Cited by 309
Self-citationLiu, S., Bai, S., Wen, Y., Lou, J., Jiang, Y., Zhu, Y., Liu, D., Li, Y., Shi, H., Liu, S., et al. (2025) · Science · doi:10.1126/science.ado1133 · Cited by 282
Self-citation
Metadata
- Authors
- Lou, J., Jiao, Y., Yang, R., Huang, Y., Xu, X., Zhang, L., Ma, Z., Yu, Y., Peng, W., Yuan, Y., Zhong, Y., Li, S., Yan, Y., Zhang, F., Liang, J., Du, X., Chang, C., & Qiu, C.-W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2022-10-17
- Volume
- 119
- Issue
- 43
- Pages
- e2209218119-e2209218119
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W4306641718
- Cited by
- 351
- References
- 53
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers. https://app.cochat.ai/papers/10.1073/pnas.2209218119
- The paper
- Lou, J., Jiao, Y., Yang, R., Huang, Y., Xu, X., Zhang, L., Ma, Z., Yu, Y., Peng, W., Yuan, Y., Zhong, Y., Li, S., Yan, Y., Zhang, F., Liang, J., Du, X., Chang, C., & Qiu, C.-W. (2022). Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2209218119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.