Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 351

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers

Open access
Lou, Jing, Jiao, Yanan, Yang, Ruisheng, Huang, Yindong, Xu, Xing, Zhang, Lei, Ma, Zhaofu, Yu, Ying, Peng, Wenyu, Yuan, Yifang, Zhong, Yuan, Li, Songyan, Yan, Yang, Zhang, Fuli, Liang, Jiangang, Du, Xiaohui, Chang, Chao, Qiu, Cheng-Wei·2022·Proceedings of the National Academy of Sciences

Abstract

Optical sensors, with great potential to convert invisible bioanalytical response into readable information, have been envisioned as a powerful platform for biological analysis and early diagnosis of diseases. However, the current extraction of sensing data is basically processed via a series of complicated and time-consuming calibrations between samples and reference, which inevitably introduce extra measurement errors and potentially annihilate small intrinsic responses. Here, we have proposed and experimentally demonstrated a calibration-free sensor for achieving high-precision biosensing detection, based on an optically controlled terahertz (THz) ultrafast metasurface. Photoexcitation of the silicon bridge enables the resonant frequency shifting from 1.385 to 0.825 THz and reaches the maximal phase variation up to 50° at 1.11 THz. The typical environmental measurement errors are completely eliminated in theory by normalizing the Fourier-transformed transmission spectra between ultrashort time delays of 37 ps, resulting in an extremely robust sensing device for monitoring the cancerous process of gastric cells. We believe that our calibration-free sensors with high precision and robust advantages can extend their implementation to study ultrafast biological dynamics and may inspire considerable innovations in the field of medical devices with nondestructive detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.2209218119

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

See all 351

Metadata

Authors
Lou, J., Jiao, Y., Yang, R., Huang, Y., Xu, X., Zhang, L., Ma, Z., Yu, Y., Peng, W., Yuan, Y., Zhong, Y., Li, S., Yan, Y., Zhang, F., Liang, J., Du, X., Chang, C., & Qiu, C.-W.
Venue
Proceedings of the National Academy of Sciences
Published
2022-10-17
Volume
119
Issue
43
Pages
e2209218119-e2209218119
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W4306641718
Cited by
351
References
53
FWCI
14.17
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers. https://app.cochat.ai/papers/10.1073/pnas.2209218119
The paper
Lou, J., Jiao, Y., Yang, R., Huang, Y., Xu, X., Zhang, L., Ma, Z., Yu, Y., Peng, W., Yuan, Y., Zhong, Y., Li, S., Yan, Y., Zhang, F., Liang, J., Du, X., Chang, C., & Qiu, C.-W. (2022). Calibration-free, high-precision, and robust terahertz ultrafast metasurfaces for monitoring gastric cancers. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2209218119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.