Multiparticle adhesive dynamics: Hydrodynamic recruitment of rolling leukocytes
Open accessThe DOI matches its Crossref record.
Abstract
The slow rolling motion of leukocytes along the walls of blood vessels mediated by specific receptor-ligand adhesion is important in inflammation and occurs in postcapillary venules over a wide range of wall shear stresses and vessel diameters. The ability of hydrodynamic collisions between cells to induce capture of free-stream leukocytes to a selectin-bearing surface under shear flow was studied experimentally by using a cell-free assay. It was found that carbohydrate-coated spherical beads, representing model leukocytes, tend to attach to the adhesive wall 4–5 cell diameters up- or downstream of a slowly rolling or stationary adhesive bead. A key feature of such “hydrodynamic recruitment” is that only glancing, indirect collisions occurring close to the plane will result in downstream attachment. A direct numerical simulation of cell capture and rolling that includes multiparticle hydrodynamic interactions is shown to reproduce the observed behavior accurately. The theory predicts that hydrodynamic recruitment will occur in the absence of buoyancy effects and over a range of shear rates, suggesting that the mechanism may be important in vivo . This theory is supported by measurements of leukocyte capture in vivo using the hamster cheek pouch model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 31
- 10.1146/annurev.bi.64.070195.000553 · DOI · Paper page
- 10.1146/annurev.med.45.1.361 · DOI · Paper page
- 10.1007/s004180050387 · DOI · Paper page
- 10.1161/01.RES.84.11.1237 · DOI · Paper page
- 10.1182/blood.V95.2.478 · DOI
- W Addison Trans Provincial Med Surg Assoc 11, 233–306 (1843).
- 10.1002/aja.1000570303 · DOI · Paper page
- 10.1002/path.1700820218 · doi:10.1002/path.1700820218
- M M Kopaniak, A C Issekutz, H Z Movat Am J Pathol 98, 485–498 (1980).
- R L Engler, M D Dahlgren, M A Peterson, A Dobbs, G W Schmid-Schönbein Am J Physiol 251, H93–H100 (1986).
- D N Granger, J N Benoit, M Suzuki, M B Grisham Am J Physiol 257, G683–G688 (1989).
- 10.1073/pnas.85.7.2315 · DOI
- 10.1002/jlb.49.3.253 · DOI
- 10.1172/JCI118888 · DOI · Paper page
- 10.1083/jcb.135.3.849 · DOI · Paper page
- 10.1161/01.RES.82.1.30 · doi:10.1161/01.res.82.1.30
- S Kim, S J Karrila Microhydrodynamics: Principles and Selected Applications (Butterworth-Heinemann, Stoneham, MA, 1991).
- 10.1182/blood.V95.9.2954.009k28_2954_2959 · doi:10.1182/blood.v95.9.2954.009k28_2954_2959
- 10.1016/S0006-3495(92)81577-1 · DOI · Paper page
- 10.1073/pnas.200240897 · DOI · Paper page
- 10.1126/science.347575 · DOI · Paper page
- 10.1016/S0006-3495(99)77169-9 · DOI · Paper page
- 10.1016/S0006-3495(96)79487-0 · doi:10.1016/s0006-3495(96)79487-0
- 10.1007/BF00370067 · doi:10.1007/bf00370067
- 10.1016/S0006-3495(01)75742-6 · DOI
- 10.1016/S0006-3495(00)76328-4 · DOI
- 10.1021/la001061d · doi:10.1021/la001061d
- 10.1016/0026-2862(84)90054-2 · DOI · Paper page
- 10.1021/la010234b · DOI
- 10.1083/jcb.136.3.717 · DOI · Paper page
- 10.3233/BIR-1992-292-305 · doi:10.3233/bir-1992-292-305
Cited by
MICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Integrin Clustering Is Driven by Mechanical Resistance from the Glycocalyx and the Substrate
Paszek, M. J., Boettiger, D., Weaver, V. M., & Hammer, D. A. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000604 · Cited by 257
Self-citationComputational and Experimental Models of Cancer Cell Response to Fluid Shear Stress
Mitchell, M. J., & King, M. R. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00044 · Cited by 221
Self-citationThe Fluid Mechanics of Cancer and Its Therapy
Koumoutsakos, P., Pivkin, I., & Milde, F. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101102 · Cited by 129
“The extended method is called multiparticle adhesive dynamics and combines a stochastic Monte Carlo simulation of single receptor-ligand bonds and calculations of concentrated suspension flow at low Reynolds number (King & Hammer 2001a, 2001b).”
MethodOrgans on chip approach: a tool to evaluate cancer -immune cells interactions
Biselli, E., Agliari, E., Barra, A., Bertani, F. R., Gerardino, A., De Ninno, A., Mencattini, A., Di Giuseppe, D., Mattei, F., Schiavoni, G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-13070-3 · Cited by 91
Multiscale Modeling in the Clinic: Drug Design and Development
Clancy, C. E., An, G., Cannon, W. R., Liu, Y., May, E. E., Ortoleva, P., Popel, A. S., Sluka, J. P., Su, J., Vicini, P., et al. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1563-0 · Cited by 62
Metadata
- Authors
- King, M. R., & Hammer, D. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-12-18
- Volume
- 98
- Issue
- 26
- Pages
- 14919-14924
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1987654715
- Cited by
- 143
- References
- 0
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.