Structural origins of diamagnetic anisotropy in proteins.
Open accessThe DOI matches its Crossref record.
Abstract
Magnetic anisotropy in proteins and polypeptides can be attributed to the diamagnetic anisotropy of the planar peptide bonds. The alpha helix in particular has large anisotropy due to the axial alignment of the peptide bonds. The regular arrangements of the peptide bonds in beta pleated sheet and collagen structures also produce substantial anisotropy, but less than for alpha helix. The anisotropy permits orientation of small structures of these types in magnetic fields of several kilogauss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Common core structure of amyloid fibrils by synchrotron X-ray diffraction 1 1Edited by F. E. Cohen
Sunde, M., Serpell, L. C., Bartlam, M., Fraser, P. E., Pepys, M. B., & Blake, C. C. F. (1997) · Journal of Molecular Biology · doi:10.1006/jmbi.1997.1348 · Cited by 1,707
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Mechanism of Action of Moderate-Intensity Static Magnetic Fields on Biological Systems
Rosen, A. D. (2003) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:39:2:163 · Cited by 381
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure
Lee, J., Shmueli, K., Fukunaga, M., van Gelderen, P., Merkle, H., Silva, A. C., & Duyn, J. H. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910222107 · Cited by 263
Structural Analysis of Alzheimer's β(1–40) Amyloid: Protofilament Assembly of Tubular Fibrils
Malinchik, S. B., Inouye, H., Szumowski, K. E., & Kirschner, D. A. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77812-9 · Cited by 255
Physical interactions of static magnetic fields with living tissues
Schenck, J. F. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.009 · Cited by 229
Duyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“In fact, anisotropic susceptibility has been observed in biological structures of various sizes including helical proteins [80], lipid bilayers [81], retinal rods [82], and muscle fibers [83].”
BackgroundWilson, S. L., Guilbert, M., Sulé‐Suso, J., Torbet, J., Jeannesson, P., Sockalingum, G. D., & Yang, Y. (2014) · The FASEB Journal · doi:10.1096/fj.13-227579 · Cited by 46
“The diamagnetic anisotropy of such proteins largely depends on the relative orientations of the peptide bonds and aromatic residues present in their structure (44).”
BackgroundInfluential
Metadata
- Authors
- Worcester, D. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1978-11
- Volume
- 75
- Issue
- 11
- Pages
- 5475-5477
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2091699998
- Cited by
- 191
- References
- 0
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.