The DOI matches its Crossref record.
Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues.
Open accessAbstract
Free radicals have been hypothesized to be important mediators of disease in a variety of organs and tissues. Electron paramagnetic resonance (EPR) spectroscopy can be applied to directly measure free radicals; however, it has not been possible to measure important biological radicals in situ because conventional spectrometer designs are not suitable for the performance of measurements on whole organs or tissues. We report the development of an EPR spectrometer designed for optimum performance in measuring free radicals in intact biological organs or tissues. This spectrometer consists of a 1- to 2-GHz microwave bridge with the source locked to the resonant frequency of a recessed gap loop-gap resonator. With this spectrometer, radical concentrations as low as 0.4 microM can be measured. Isolated beating hearts were studied in which simultaneous real time measurements of free radicals and cardiac contractile function were performed. This in vivo EPR technique was applied to study the kinetics of free radical uptake and metabolism in normally perfused and globally ischemic hearts. In addition, we show that this technique can be used to noninvasively measure tissue oxygen consumption. Thus, it is demonstrated that EPR spectroscopy can be applied to directly measure in vivo free radical metabolism and tissue oxygen consumption. This technique offers great promise in the study of in vivo free radical generation and the effects of this radical generation on whole biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of oxidants and free radicals in reperfusion injury
ZWEIER, J., & TALUKDER, M. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.02.025 · Cited by 736
Self-citationWhat's new in stable radical chemistry?
Hicks, R. G. (2007) · Organic & Biomolecular Chemistry · doi:10.1039/b617142g · Cited by 536
Ide, T., Tsutsui, H., Kinugawa, S., Suematsu, N., Hayashidani, S., Ichikawa, K., Utsumi, H., Machida, Y., Egashira, K., & Takeshita, A. (2000) · Circulation Research · doi:10.1161/01.res.86.2.152 · Cited by 427
Zweier, J. L., Kuppusamy, P., Williams, R., Rayburn, B. K., Smith, D., Weisfeldt, M. L., & Flaherty, J. T. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)47240-2 · Cited by 384
Self-citationNon-Enzymatic Nitric Oxide Synthesis in Biological Systems
Zweier, J. L., Samouilov, A., & Kuppusamy, P. (1999) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(99)00018-3 · Cited by 363
Self-citation
Metadata
- Authors
- Zweier, J. L., & Kuppusamy, P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1988-08
- Volume
- 85
- Issue
- 15
- Pages
- 5703-5707
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2069472071
- Cited by
- 162
- References
- 0
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues. https://app.cochat.ai/papers/10.1073/pnas.85.15.5703
- The paper
- Zweier, J. L., & Kuppusamy, P. (1988). Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.85.15.5703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.