Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Constant denaturant gel electrophoresis as a rapid screening technique for p53 mutations.

Open access
Børresen, A L, Hovig, E, Smith-Sørensen, B, Malkin, D, Lystad, S, Andersen, T I, Nesland, J M, Isselbacher, K J, Friend, S H · 1991 · Proceedings of the National Academy of Sciences

Abstract

At present, mutation of the p53 gene appears to be the most common genetic alteration found in human cancers. These mutations can occur within many different regions of the gene. We have developed a modification of denaturing gradient gel electrophoresis termed "constant denaturant gel electrophoresis" (CDGE), which provides a rapid and sensitive method to screen the four conserved regions within the p53 gene where the majority of p53 mutations have been reported. The sensitivity of CDGE was first tested with known p53 mutations in all four conserved regions. The CDGE technique was then used to screen 32 breast carcinomas that had been analyzed by immunohistochemical methods for altered p53 protein levels and whose DNA had already been shown to have loss of heterozygosity for a chromosome 17p marker. By immunostaining techniques, only 6 of the 32 tumors had elevated p53 expression. However, CDGE detected p53 mutations in 11 of the 32 tumors. DNA sequence analysis was performed to determine the nucleotide positions of these mutations in all 11 samples. Loss of heterozygosity for the pYNZ22 or p144D6 markers did not associate with either the loss of heterozygosity at the p53 locus or the mutations detected by CDGE. We conclude that CDGE is a rapid and effective technique to screen for p53 mutations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.88.19.8405

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 190

Metadata

Authors
Børresen, A. L., Hovig, E., Smith-Sørensen, B., Malkin, D., Lystad, S., Andersen, T. I., Nesland, J. M., Isselbacher, K. J., & Friend, S. H.
Venue
Proceedings of the National Academy of Sciences
Published
1991-10
Volume
88
Issue
19
Pages
8405-8409
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2005530011
Cited by
190
References
2
FWCI
10.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Constant denaturant gel electrophoresis as a rapid screening technique for p53 mutations. https://app.cochat.ai/papers/10.1073/pnas.88.19.8405
The paper
Børresen, A. L., Hovig, E., Smith-Sørensen, B., Malkin, D., Lystad, S., Andersen, T. I., Nesland, J. M., Isselbacher, K. J., & Friend, S. H. (1991). Constant denaturant gel electrophoresis as a rapid screening technique for p53 mutations. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.88.19.8405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.