The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamic reorientation of cortical microtubules, from transverse to longitudinal, in living plant cells.
Open accessAbstract
The direction in which plant tissue cells expand is reflected in the alignment of microtubules in the cortical array. When microtubules and coaligned wall microfibrils are arranged transversely around the cell, turgor pressure is chaneled into cell elongation. However, various agents (such as wounding, ethylene, abscisic acid) can cause the microtubules to reorientate by 90 degrees so that they become aligned parallel to the cell's long axis, allowing lateral expansion instead of elongation. The mechanism by which microtubules undergo rapid shifts of alignment is crucial to understanding growth control in plants, but because current models are derived from studies on fixed cells, nothing is known about the dynamics of converting one microtubule alignment to another. Cells tend to have one predominant microtubule alignment--transverse, oblique, or longitudinal--but it is not established whether each represents a stable independent set that only changes by rounds of complete de- and repolymerization, or whether reorientation is a more continuous process involving movement of stable or dynamic microtubules. By microinjecting pea (Pisum sativum) epidermal cells with rhodamine-conjugated brain tubulin and optically sectioning them by confocal laser scanning microscopy, we could follow labeled microtubules for up to 2 hr as they reorientate. Reorientation does not occur by complete depolymerization of microtubules in one orientation followed by polymerization of a new array in another orientation. Instead, increased numbers of discordant microtubules in nontransverse alignment appear in particular locations. Neighboring microtubules then adopt the new alignment, so that there is a stage during which different alignments coexist before the array on the outer tangential cell face finally adopts a uniform steeply oblique/longitudinal configuration. Rapid fluorescence recovery after photobleaching confirms that bundles of cortical microtubules are not stable but exhibit properties consistent with dynamic instability. Dynamic microtubules offer a mechanism for rapid growth responses to a range of physiological stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic instability of microtubule growth
Mitchison, T., & Kirschner, M. (1984) · Nature · doi:10.1038/312237a0 · Cited by 3,337
Cited by
Visualization of Cellulose Synthase Demonstrates Functional Association with Microtubules
Paredez, A. R., Somerville, C. R., & Ehrhardt, D. W. (2006) · Science · doi:10.1126/science.1126551 · Cited by 1,371
Roman, G., Lubarsky, B., Kieber, J. J., Rothenberg, M., & Ecker, J. R. (1995) · Genetics · doi:10.1093/genetics/139.3.1393 · Cited by 592
Microtubules and microtubule-associated proteins
Mandelkow, E., & Mandelkow, E.-M. (1995) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(95)80047-6 · Cited by 458
Sustained Microtubule Treadmilling in Arabidopsis Cortical Arrays
Shaw, S. L., Kamyar, R., & Ehrhardt, D. W. (2003) · Science · doi:10.1126/science.1083529 · Cited by 454
Marc, J., Granger, C. L., Brincat, J., Fisher, D. D., Kao, T.-H., McCubbin, A. G., & Cyr, R. J. (1998) · The Plant Cell · doi:10.1105/tpc.10.11.1927 · Cited by 384
Metadata
- Authors
- Yuan, M., Shaw, P. J., Warn, R. M., & Lloyd, C. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1994-06-21
- Volume
- 91
- Issue
- 13
- Pages
- 6050-6053
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2017769716
- Cited by
- 207
- References
- 1
- FWCI
- 13.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic reorientation of cortical microtubules, from transverse to longitudinal, in living plant cells. https://app.cochat.ai/papers/10.1073/pnas.91.13.6050
- The paper
- Yuan, M., Shaw, P. J., Warn, R. M., & Lloyd, C. W. (1994). Dynamic reorientation of cortical microtubules, from transverse to longitudinal, in living plant cells. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.91.13.6050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.