The DOI matches its Crossref record.
Atomic force microscopy produces faithful high-resolution images of protein surfaces in an aqueous environment.
Open accessAbstract
The atomic force microscope has the potential to monitor structural changes of a biological system in its native environment. To correlate them with the biological function at a molecular level, high lateral and vertical resolution are required. Here we demonstrate that the atomic force microscope is capable of imaging the surface of the hexagonally packed intermediate layer of Deinococcus radiodurans in buffer solution with a lateral resolution of 1 nm and a vertical resolution of 0.1 nm. On average, these topographs differ from those determined by electron microscopy by <0.5 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring the viscoelastic properties of human platelets with the atomic force microscope
Radmacher, M., Fritz, M., Kacher, C. M., Cleveland, J. P., & Hansma, P. K. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79602-9 · Cited by 839
Direct Observation of Enzyme Activity with the Atomic Force Microscope
Radmacher, M., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Science · doi:10.1126/science.8079171 · Cited by 405
Atomic Force Microscopy, a Powerful Tool in Microbiology
Dufrêne, Y. F. (2002) · Journal of Bacteriology · doi:10.1128/jb.184.19.5205-5213.2002 · Cited by 376
Electrostatically Balanced Subnanometer Imaging of Biological Specimens by Atomic Force Microscope
Müller, D. J., Fotiadis, D., Scheuring, S., Müller, S. A., & Engel, A. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77275-9 · Cited by 354
Self-citationSchwesinger, F., Ros, R., Strunz, T., Anselmetti, D., Güntherodt, H.-J., Honegger, A., Jermutus, L., Tiefenauer, L., & Plückthun, A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.18.9972 · Cited by 343
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Imaging purple membranes in aqueous solutions at sub-nanometer resolution by atomic force microscopy
Müller, D. J., Schabert, F. A., Büldt, G., & Engel, A. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80345-0 · Cited by 324
Self-citationSchäfer, G., Engelhard, M., & Müller, V. (1999) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.63.3.570-620.1999 · Cited by 291
Adsorption of Biological Molecules to a Solid Support for Scanning Probe Microscopy
Müller, D. J., Amrein, M., & Engel, A. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3875 · Cited by 287
Self-citationTapping-Mode Atomic Force Microscopy Produces Faithful High-Resolution Images of Protein Surfaces
Möller, C., Allen, M., Elings, V., Engel, A., & Müller, D. J. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76966-3 · Cited by 274
Self-citationUsing nanotechniques to explore microbial surfaces
Dufrêne, Y. F. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro905 · Cited by 263
Müller, D. J., & Engel, A. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78195-5 · Cited by 257
Self-citation
Metadata
- Authors
- Karrasch, S., Hegerl, R., Hoh, J. H., Baumeister, W., & Engel, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1994-02
- Volume
- 91
- Issue
- 3
- Pages
- 836-838
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2032104184
- Cited by
- 175
- References
- 0
- FWCI
- 11.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.