Amperometric detection of stimulus-induced quantal release of catecholamines from cultured superior cervical ganglion neurons.
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Amperometry has been used for real-time electrochemical detection of the quantal release of catecholamines and indolamines from secretory granules in chromaffin and mast cells. Using improved-sensitivity carbon fiber electrodes, we now report the detection of quantal catecholamine release at the surface of somas of neonatal superior cervical ganglion neurons that are studded with axon varicosities containing synaptic vesicles. Local application of a bath solution containing high K+ or black widow spider venom, each of which greatly enhances spontaneous quantal release of transmitter at synapses, evoked barrages of small-amplitude (2-20 pA), short-duration (0.5-2 ms) amperometric quantal "spikes". The median spike charge was calculated as 11.3 fC. This figure corresponds to 3.5 x 10(4) catecholamine molecules per quantum of release, or approximately 1% that evoked by the discharge of the contents of a chromaffin granule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wightman, R. M., Jankowski, J. A., Kennedy, R. T., Kawagoe, K. T., Schroeder, T. J., Leszczyszyn, D. J., Near, J. A., Diliberto, E. J., & Viveros, O. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.23.10754 · Cited by 893
Chow, R. H., von Rüden, L., & Neher, E. (1992) · Nature · doi:10.1038/356060a0 · Cited by 817
Cited by
A genetically encoded fluorescent sensor for rapid and specific in vivo detection of norepinephrine
Feng, J., Zhang, C., Lischinsky, J. E., Jing, M., Zhou, J., Wang, H., Zhang, Y., Dong, A., Wu, Z., Wu, H., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.02.037 · Cited by 545
Peripheral Chemoreceptors: Function and Plasticity of the Carotid Body
Kumar, P., & Prabhakar, N. R. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100069 · Cited by 530
Electrochemical Monitoring of Single Cell Secretion: Vesicular Exocytosis and Oxidative Stress
Amatore, C., Arbault, S., Guille, M., & Lemaître, F. (2008) · Chemical Reviews · doi:10.1021/cr068062g · Cited by 406
Analysis of exocytotic events recorded by amperometry
Mosharov, E. V., & Sulzer, D. (2005) · Nature Methods · doi:10.1038/nmeth782 · Cited by 349
Presynaptic Recording of Quanta from Midbrain Dopamine Neurons and Modulation of the Quantal Size
Pothos, E. N., Davila, V., & Sulzer, D. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-11-04106.1998 · Cited by 320
Metadata
- Authors
- Zhou, Z., & Misler, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1995-07-18
- Volume
- 92
- Issue
- 15
- Pages
- 6938-6942
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2045846621
- Cited by
- 102
- References
- 2
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.