Controlling cell attachment on contoured surfaces with self-assembled monolayers of alkanethiolates on gold.
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper describes a method based on experimentally simple techniques--microcontact printing and micromolding in capillaries--to prepare tissue culture substrates in which both the topology and molecular structure of the interface can be controlled. The method combines optically transparent contoured surfaces with self-assembled monolayers (SAMs) of alkanethiolates on gold to control interfacial characteristics; these tailored interfaces, in turn, control the adsorption of proteins and the attachment of cells. The technique uses replica molding in poly(dimethylsiloxane) molds having micrometer-scale relief patterns on their surfaces to form a contoured film of polyurethane supported on a glass slide. Evaporation of a thin (< 12 nm) film of gold on this surface-contoured polyurethane provides an optically transparent substrate, on which SAMs of terminally functionalized alkanethiolates can be formed. In one procedure, a flat poly(dimethylsiloxane) stamp was used to form a SAM of hexadecanethiolate on the raised plateaus of the contoured surface by contact printing hexadecanethiol [HS(CH2)15CH3]; a SAM terminated in tri(ethylene glycol) groups was subsequently formed on the bare gold remaining in the grooves by immersing the substrate in a solution of a second alkanethiol [HS(CH2)11(OCH2CH2)3OH]. Then this patterned substrate was immersed in a solution of fibronectin, the protein adsorbed only on the methyl-terminated plateau regions of the substrate [the tri(ethylene glycol)-terminated regions resisted the adsorption of protein]; bovine capillary endothelial cells attached only on the regions that adsorbed fibronectin. A complementary procedure confined protein adsorption and cell attachment to the grooves in this substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453
Self-citationIngber, D. E., & Folkman, J. (1989) · The Journal of cell biology · doi:10.1083/jcb.109.1.317 · Cited by 868
Self-citationControlled outgrowth of dissociated neurons on patterned substrates
Kleinfeld, D., Kahler, K., & Hockberger, P. (1988) · The Journal of Neuroscience · doi:10.1523/jneurosci.08-11-04098.1988 · Cited by 569
In Situ Interfacial Mass Detection with Piezoelectric Transducers
Ward, M. D., & Buttry, D. A. (1990) · Science · doi:10.1126/science.249.4972.1000 · Cited by 525
Electrically conducting polymers can noninvasively control the shape and growth of mammalian cells.
Wong, J. Y., Langer, R., & Ingber, D. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.8.3201 · Cited by 519
Self-citationSigal, G. B., Bamdad, C., Barberis, A., Strominger, J., & Whitesides, G. M. (1996) · Analytical Chemistry · doi:10.1021/ac9504023 · Cited by 498
Self-citationCell guidance by ultrafine topography in vitro
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1991) · Journal of Cell Science · doi:10.1242/jcs.99.1.73 · Cited by 491
Signaling for Growth Orientation and Cell Differentiation by Surface Topography in Uromyces
Hoch, H. C., Staples, R. C., Whitehead, B., Comeau, J., & Wolf, E. D. (1987) · Science · doi:10.1126/science.235.4796.1659 · Cited by 363
Chou, L., Firth, J. D., Uitto, V.-J., & Brunette, D. M. (1995) · Journal of Cell Science · doi:10.1242/jcs.108.4.1563 · Cited by 310
Micropatterned substratum adhesiveness: A model for morphogenetic cues controlling cell behavior
Britland, S. T., Clark, P., Connolly, P., & Moores, G. R. (1992) · Experimental Cell Research · doi:10.1016/0014-4827(92)90157-4 · Cited by 160
Green, A. M., Jansen, J. A., van der Waerden, J. P. C. M., & von Recum, A. F. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280515 · Cited by 151
Spargo, B. J., Testoff, M. A., Nielsen, T. B., Stenger, D. A., Hickman, J. J., & Rudolph, A. S. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.23.11070 · Cited by 123
Macrophage response to microtextured silicone
Schmidt, J. A., & von Recum, A. F. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90138-e · Cited by 90
O’Neill, C., Jordan, P., Riddle, P., & Ireland, G. (1990) · Journal of Cell Science · doi:10.1242/jcs.95.4.577 · Cited by 79
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Self-citationXia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Self-citationHydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationPatterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Metadata
- Authors
- Mrksich, M., Chen, C. S., Xia, Y., Dike, L. E., Ingber, D. E., & Whitesides, G. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1996-10
- Volume
- 93
- Issue
- 20
- Pages
- 10775-10778
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2074139312
- Cited by
- 425
- References
- 14
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.