High-precision position-specific isotope analysis
Open accessAbstract
Intramolecular carbon isotope distributions reflect details of the origin of organic compounds and may record the status of complex systems, such as environmental or physiological states. A strategy is reported here for high-precision determination of 13C/12C ratios at specific positions in organic compounds separated from complex mixtures. Free radical fragmentation of methyl palmitate, a test compound, is induced by an open tube furnace. Two series of peaks corresponding to bond breaking from each end of the molecule are analyzed by isotope ratio mass spectrometry and yield precisions of SD(delta-13C) < 0.4 per thousand. Isotope labeling in the carboxyl, terminal, and methyl positions demonstrates the absence of rearrangement during activation and fragmentation. Negligible isotopic fractionation was observed as degree of fragmentation was adjusted by changing pyrolysis temperature. [1-13C]methyl palmitate with overall delta-13C = 4.06 per thousand, yielded values of +457 per thousand for the carboxyl position, in agreement with expectations from the dilution, and an average of -27.95 per thousand for the rest of the molecule, corresponding to -27.46 per thousand for the olefin series. These data demonstrate the feasibility of automated high-precision position-specific analysis of carbon for molecules contained in complex mixtures.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For tracer studies and isotope balances at isotope tracer levels greater than natural abundance, R or d yield increasingly incorrect mass or amount-of-substance balance with increasing x, whereas atom fraction, isotope-number fraction, or 'iE give accurate results.
“For tracer studies and isotope balances at isotope tracer levels greater than those of natural abundance, either of the quantities atom fraction, isotope-number fraction, or ' i E give accurate results as opposed to the quantities R( i E) or d i E, which yield increasingly incorrect mass or amount-of-substance balance with increasing values of x( i E). [12,13,18]”
From Guidelines and recommended terms for expression of stable-isotope-ratio and gas-ratio measurement results (2011) · cites this paper as [18]
Cited by
Sorted by citations
Coplen, T. B. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5129 · Cited by 1,831 · see citing works
“Also, a wide range of comments was received on an early draft of this manuscript from subject experts S. Assonov, K. Auerswald, D. Barden, T. Brenna, J. H. Dymond, J. Farquhar, J. Landwehr, I. M. Mills, M. J. T. Milton, T. Preston, G. Singleton, A. J. Thor, M. H. Thiemens, H. Tobias, and F. von Blanckenburg.”
BackgroundMethodInfluentialThe isotopic anatomies of molecules and minerals
Eiler, J. M. (2013) · Annual Review of Earth and Planetary Sciences · doi:10.1146/annurev-earth-042711-105348 · Cited by 96 · see citing works
- Authors
- Corso, T. N., & Brenna, J. T.
- Affiliations
- Cornell University (US)
- ORCID
- Brenna, J. Thomas
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 1997-02-18
- Volume
- 94
- Issue
- 4
- Pages
- 1049-1053
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC19741
- OpenAlex
- W1969321006
- Cited by
- 116
- References
- 0
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 5 · 2018: 8 · 2017: 6 · 2016: 4 · 2015: 7 · 2014: 6 · 2013: 3 · 2012: 5
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM049209)
- National Institute of Diabetes and Digestive and Kidney Diseases (T32DK007158)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Environmental Science › Ecology › Isotope Analysis in Ecology
- Physical Sciences › Earth and Planetary Sciences › Paleontology › Archaeology and ancient environmental studies
- Keywords
- methyl palmitate, pyrolysis, isotopic labeling, isotope fractionation, complex mixtures, isotope ratio mass spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review