Real-time light-driven dynamics of the fluorescence emission in single green fluorescent protein molecules
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Real-time single-molecule fluorescence detection using confocal and near-field scanning optical microscopy has been applied to elucidate the nature of the “on–off” blinking observed in the Ser-65 → Thr (S65T) mutant of the green fluorescent protein (GFP). Fluorescence time traces as a function of the excitation intensity, with a time resolution of 100 μs and observation times up to 65 s, reveal the existence of a nonemissive state responsible for the long dark intervals in the GFP. We find that excitation intensity has a dramatic effect on the blinking. Whereas the time during which the fluorescence is on becomes shorter as the intensity is increased, the off- times are independent of excitation intensity. Statistical analysis of the on- and off- times renders a characteristic off- time of 1.6 ± 0.2 s and allows us to calculate a transition yield of ≈0.5 × 10 −5 from the emissive to the nonemissive state. The saturation excitation intensity at which on- and off- times are equal is ≈1.5 kW/cm 2 . On the basis of the single-molecule data we calculate an absorption cross section of 6.5 × 10 −17 cm 2 for the S65T mutant. These results have important implications for the use of the GFP to follow dynamic processes in time at the single-molecular level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Bout, D. A. V., Yip, W.-T., Hu, D., Fu, D.-K., Swager, T. M., & Barbara, P. F. (1997) · Science · doi:10.1126/science.277.5329.1074 · Cited by 521
Cited by
Fast, long-term, super-resolution imaging with Hessian structured illumination microscopy
Huang, X., Fan, J., Li, L., Liu, H., Wu, R., Wu, Y., Wei, L., Mao, H., Lal, A., Xi, P., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4115 · Cited by 661
A review of progress in single particle tracking: from methods to biophysical insights
Manzo, C., & Garcia-Parajo, M. F. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/12/124601 · Cited by 597
Self-citationAdvanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
Fluorescence Correlation Spectroscopy and Its Potential for Intracellular Applications
Schwille, P. (2001) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:34:3:383 · Cited by 367
Photoinduced Chemistry in Fluorescent Proteins: Curse or Blessing?
Acharya, A., Bogdanov, A. M., Grigorenko, B. L., Bravaya, K. B., Nemukhin, A. V., Lukyanov, K. A., & Krylov, A. I. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00238 · Cited by 269
Kulzer, F., & Orrit, M. (2004) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103816 · Cited by 252
Amplified energy transfer in conjugated polymer nanoparticle tags and sensors
Tian, Z., Yu, J., Wu, C., Szymanski, C., & McNeill, J. (2010) · Nanoscale · doi:10.1039/c0nr00322k · Cited by 208
Luijsterburg, M. S., Goedhart, J., Moser, J., Kool, H., Geverts, B., Houtsmuller, A. B., Mullenders, L. H. F., Vermeulen, W., & van Driel, R. (2007) · Journal of Cell Science · doi:10.1242/jcs.008367 · Cited by 105
“This initial very fast recovery (t1/2=0.1 seconds) is probably due to fluorescence blinking, given that the average lifetime of GFP in a dark non-emissive state is around 2 seconds (Garcia-Parajo et al., 2000).”
BackgroundInfluentialCellular Concentrations of DDB2 Regulate Dynamic Binding of DDB1 at UV-Induced DNA Damage
Alekseev, S., Luijsterburg, M. S., Pines, A., Geverts, B., Mari, P.-O., Giglia-Mari, G., Lans, H., Houtsmuller, A. B., Mullenders, L. H. F., Hoeijmakers, J. H. J., et al. (2008) · Molecular and Cellular Biology · doi:10.1128/mcb.01108-08 · Cited by 38
“To compensate for the effect of fluorescence blinking (19, 41), the corrected”
Background
Metadata
- Authors
- Garcia-Parajo, M. F., Segers-Nolten, G. M. J., Veerman, J.-A., Greve, J., & van Hulst, N. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-06-20
- Volume
- 97
- Issue
- 13
- Pages
- 7237-7242
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2024703548
- Cited by
- 171
- References
- 2
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.