The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Myosin VI Steps via a Hand-over-Hand Mechanism with Its Lever Arm Undergoing Fluctuations when Attached to Actin
Open accessAbstract
Myosin VI is a reverse direction myosin motor that, as a dimer, moves processively on actin with an average center-of-mass movement of approximately 30 nm for each step. We labeled myosin VI with a single fluorophore on either its motor domain or on the distal of two calmodulins (CaMs) located on its putative lever arm. Using a technique called FIONA (fluorescence imaging with one nanometer accuracy), step size was observed with a standard deviation of <1.5 nm, with 0.5-s temporal resolution, and observation times of minutes. Irrespective of probe position, the average step size of a labeled head was approximately 60 nm, strongly supporting a hand-over-hand model of motility and ruling out models in which the unique myosin VI insert comes apart. However, the CaM probe displayed large spatial fluctuations (presence of ATP but not ADP or no nucleotide) around the mean position, whereas the motor domain probe did not. This supports a model of myosin VI motility in which the lever arm is either mechanically uncoupled from the motor domain or is undergoing reversible isomerization for part of its motile cycle on actin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetic Mechanism and Regulation of Myosin VI
De La Cruz, E. M., Ostap, E. M., & Sweeney, H. L. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m104136200 · Cited by 234
Self-citation
Cited by
Molecular Motors: A Theorist's Perspective
Kolomeisky, A. B., & Fisher, M. E. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104532 · Cited by 575
Structural and Functional Insights into the Myosin Motor Mechanism
Sweeney, H. L., & Houdusse, A. (2010) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133751 · Cited by 422
Self-citationCargo transport: molecular motors navigate a complex cytoskeleton
Ross, J. L., Ali, M. Y., & Warshaw, D. M. (2008) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2007.11.006 · Cited by 350
Churchman, L. S., Ökten, Z., Rock, R. S., Dawson, J. F., & Spudich, J. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409487102 · Cited by 340
Fluorescence Imaging with One Nanometer Accuracy: Application to Molecular Motors
Yildiz, A., & Selvin, P. R. (2005) · Accounts of Chemical Research · doi:10.1021/ar040136s · Cited by 324
Self-citation
Metadata
- Authors
- Yildiz, A., Park, H., Safer, D., Yang, Z., Chen, L.-Q., Selvin, P. R., & Sweeney, H. L.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 2004-09
- Volume
- 279
- Issue
- 36
- Pages
- 37223-37226
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2145455826
- Cited by
- 180
- References
- 1
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myosin VI Steps via a Hand-over-Hand Mechanism with Its Lever Arm Undergoing Fluctuations when Attached to Actin. https://app.cochat.ai/papers/10.1074/jbc.c400252200
- The paper
- Yildiz, A., Park, H., Safer, D., Yang, Z., Chen, L.-Q., Selvin, P. R., & Sweeney, H. L. (2004). Myosin VI Steps via a Hand-over-Hand Mechanism with Its Lever Arm Undergoing Fluctuations when Attached to Actin. Journal of Biological Chemistry. https://doi.org/10.1074/jbc.c400252200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.