Genetically Encoded Indicators of Cellular Calcium Dynamics Based on Troponin C and Green Fluorescent Protein
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Genetic calcium probes offer tremendous potential in the fields of neuroscience, cell biology, and pharmaceutical screening. Previously, ratiometric and non-ratiometric indicators of cellular calcium dynamics have been described that consist of mutants of the green fluorescent protein (GFP) as fluorophores and calmodulin as calcium-binding moiety in several configurations. However, these calmodulin-based types of probes have a series of deficiencies, such as reduced dynamic ranges, when expressed within transgenic organisms and lack of calcium sensitivity in certain targetings. We developed novel types of calcium probes based on troponin C variants from skeletal and cardiac muscle. These indicators have ratio changes up to 140%, K(d)s ranging from 470 nm to 29 microm, and improved subcellular targeting properties. We targeted the indicators to the plasma membrane of HEK293 cells and primary hippocampal neurons. Upon long lasting depolarization, submembrane calcium levels in hippocampal neurons were found to be in equilibrium with bulk cytosolic calcium levels, suggesting no standing gradient persists from the membrane toward the cytosol. We expect that such novel indicators using specialized calcium sensing proteins will be minimally interacting with the cellular biochemical machinery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Creating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Regulation of Contraction in Striated Muscle
Gordon, A. M., Homsher, E., & Regnier, M. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.853 · Cited by 1,737
A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Reducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Self-citationCircularly permuted green fluorescent proteins engineered to sense Ca 2+
Nagai, T., Sawano, A., Park, E. S., & Miyawaki, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051636098 · Cited by 966
Circular permutation and receptor insertion within green fluorescent proteins
Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11241 · Cited by 961
Dynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Self-citationModulation of pH by neuronal activity
Chesler, M., & Kaila, K. (1992) · Trends in Neurosciences · doi:10.1016/0166-2236(92)90191-a · Cited by 531
Aronheim, A., Engelberg, D., Li, N., Al-Alawi, N., Schlessinger, J., & Karin, M. (1994) · Cell · doi:10.1016/0092-8674(94)90271-2 · Cited by 458
Cited by
Fluorescent Sensors for Measuring Metal Ions in Living Systems
Carter, K. P., Young, A. M., & Palmer, A. E. (2014) · Chemical Reviews · doi:10.1021/cr400546e · Cited by 2,451
Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators
Tian, L., Hires, S. A., Mao, T., Huber, D., Chiappe, M. E., Chalasani, S. H., Petreanu, L., Akerboom, J., McKinney, S. A., Schreiter, E. R., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1398 · Cited by 1,967
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Microdomains of Intracellular Ca2+: Molecular Determinants and Functional Consequences
Rizzuto, R., & Pozzan, T. (2006) · Physiological Reviews · doi:10.1152/physrev.00004.2005 · Cited by 1,206
Genetic Dissection of Neural Circuits
Luo, L., Callaway, E. M., & Svoboda, K. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.002 · Cited by 756
Advances and current challenges in calcium signaling
Kudla, J., Becker, D., Grill, E., Hedrich, R., Hippler, M., Kummer, U., Parniske, M., Romeis, T., & Schumacher, K. (2018) · New Phytologist · doi:10.1111/nph.14966 · Cited by 662
Palmer, A. E., Jin, C., Reed, J. C., & Tsien, R. Y. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408030101 · Cited by 625
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
“This roughly tracks the progression of GECI development, which was initially useful in a limited number of contexts (119, 120), but, throughmultiple rounds of rational and screening-based modifications (121, 122), GCaMP, the archetypicalmember of this protein class, is now useful for the simultaneous readout of thousa…”
BackgroundCa2+ Indicators Based on Computationally Redesigned Calmodulin-Peptide Pairs
Palmer, A. E., Giacomello, M., Kortemme, T., Hires, S. A., Lev-Ram, V., Baker, D., & Tsien, R. Y. (2006) · Chemistry & Biology · doi:10.1016/j.chembiol.2006.03.007 · Cited by 508
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
A genetically encoded calcium indicator for chronic in vivo two-photon imaging
Mank, M., Santos, A. F., Direnberger, S., Mrsic-Flogel, T. D., Hofer, S. B., Stein, V., Hendel, T., Reiff, D. F., Levelt, C., Borst, A., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1243 · Cited by 475
Self-citationElectrophysiology in the age of light
Scanziani, M., & Häusser, M. (2009) · Nature · doi:10.1038/nature08540 · Cited by 468
Measuring calcium signaling using genetically targetable fluorescent indicators
Palmer, A. E., & Tsien, R. Y. (2006) · Nature Protocols · doi:10.1038/nprot.2006.172 · Cited by 463
Tallini, Y. N., Ohkura, M., Choi, B.-R., Ji, G., Imoto, K., Doran, R., Lee, J., Plan, P., Wilson, J., Xin, H.-B., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509378103 · Cited by 439
Optimized ratiometric calcium sensors for functional in vivo imaging of neurons and T lymphocytes
Thestrup, T., Litzlbauer, J., Bartholomäus, I., Mues, M., Russo, L., Dana, H., Kovalchuk, Y., Liang, Y., Kalamakis, G., Laukat, Y., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2773 · Cited by 366
Self-citationGenetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Optically monitoring voltage in neurons by photo-induced electron transfer through molecular wires
Miller, E. W., Lin, J. Y., Frady, E. P., Steinbach, P. A., Kristan, W. B., & Tsien, R. Y. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1120694109 · Cited by 323
A FRET-Based Calcium Biosensor with Fast Signal Kinetics and High Fluorescence Change
Mank, M., Reiff, D. F., Heim, N., Friedrich, M. W., Borst, A., & Griesbeck, O. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.073536 · Cited by 296
Self-citationEngel, J., Jr., Thompson, P. M., Stern, J. M., Staba, R. J., Bragin, A., & Mody, I. (2013) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32835ee5b8 · Cited by 283
Genetically Encoded Calcium Indicators
Mank, M., & Griesbeck, O. (2008) · Chemical Reviews · doi:10.1021/cr078213v · Cited by 283
Self-citationFRET‐based genetically encoded sensors allow high‐resolution live cell imaging of Ca2+ dynamics
Krebs, M., Held, K., Binder, A., Hashimoto, K., Den Herder, G., Parniske, M., Kudla, J., & Schumacher, K. (2012) · The Plant Journal · doi:10.1111/j.1365-313x.2011.04780.x · Cited by 265
Genetically encoded optical indicators for the analysis of neuronal circuits
Knöpfel, T. (2012) · Nature reviews. Neuroscience · doi:10.1038/nrn3293 · Cited by 205
Fluorescent Protein-Based Sensors for Detecting Essential Metal Ions across the Tree of Life
Jensen, G. C., Janis, M. K., Nguyen, H. N., David, O. W., & Zastrow, M. L. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02695 · Cited by 25
Metadata
- Authors
- Heim, N., & Griesbeck, O.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 2004-04
- Volume
- 279
- Issue
- 14
- Pages
- 14280-14286
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2074698051
- Cited by
- 259
- References
- 22
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.