Accurate Quantification of Cardiovascular Biomarkers in Serum Using Protein Standard Absolute Quantification (PSAQ™) and Selected Reaction Monitoring
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Development of new biomarkers needs to be significantly accelerated to improve diagnostic, prognostic, and toxicity monitoring as well as therapeutic follow-up. Biomarker evaluation is the main bottleneck in this development process. Selected Reaction Monitoring (SRM) combined with stable isotope dilution has emerged as a promising option to speed this step, particularly because of its multiplexing capacities. However, analytical variabilities because of upstream sample handling or incomplete trypsin digestion still need to be resolved. In 2007, we developed the PSAQ™ method (Protein Standard Absolute Quantification), which uses full-length isotope-labeled protein standards to quantify target proteins. In the present study we used clinically validated cardiovascular biomarkers (LDH-B, CKMB, myoglobin, and troponin I) to demonstrate that the combination of PSAQ and SRM (PSAQ-SRM) allows highly accurate biomarker quantification in serum samples. A multiplex PSAQ-SRM assay was used to quantify these biomarkers in clinical samples from myocardial infarction patients. Good correlation between PSAQ-SRM and ELISA assay results was found and demonstrated the consistency between these analytical approaches. Thus, PSAQ-SRM has the capacity to improve both accuracy and reproducibility in protein analysis. This will be a major contribution to efficient biomarker development strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Rauniyar, N. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161226120 · Cited by 406
“The use of Quantification concatamers (QconCAT) and heavy-labeled full-length proteins as internal standard addresses these issues to a certain extent [31,37,53].”
BackgroundAdvances in targeted proteomics and applications to biomedical research
Shi, T., Song, E., Nie, S., Rodland, K. D., Liu, T., Qian, W., & Smith, R. D. (2016) · PROTEOMICS · doi:10.1002/pmic.201500449 · Cited by 257
Applications of targeted proteomics in systems biology and translational medicine
Ebhardt, H. A., Root, A., Sander, C., & Aebersold, R. (2015) · PROTEOMICS · doi:10.1002/pmic.201500004 · Cited by 184
Simon, R., Girod, M., Fonbonne, C., Salvador, A., Clément, Y., Lantéri, P., Amouyel, P., Lambert, J. C., & Lemoine, J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.018861 · Cited by 92
Metadata
- Authors
- Huillet, C., Adrait, A., Lebert, D., Picard, G., Trauchessec, M., Louwagie, M., Dupuis, A., Hittinger, L., Ghaleh, B., Le Corvoisier, P., Jaquinod, M., Garin, J., Bruley, C., & Brun, V.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 11
- Issue
- 2
- Pages
- M111.008235
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2162675827
- Cited by
- 83
- References
- 3
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate Quantification of Cardiovascular Biomarkers in Serum Using Protein Standard Absolute Quantification (PSAQ™) and Selected Reaction Monitoring. https://app.cochat.ai/papers/10.1074/mcp.m111.008235
- The paper
- Huillet, C., Adrait, A., Lebert, D., Picard, G., Trauchessec, M., Louwagie, M., Dupuis, A., Hittinger, L., Ghaleh, B., Le Corvoisier, P., Jaquinod, M., Garin, J., Bruley, C., & Brun, V. (2012). Accurate Quantification of Cardiovascular Biomarkers in Serum Using Protein Standard Absolute Quantification (PSAQ™) and Selected Reaction Monitoring. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m111.008235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.