The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
PEAKS DB: De Novo Sequencing Assisted Database Search for Sensitive and Accurate Peptide Identification
Open accessAbstract
Many software tools have been developed for the automated identification of peptides from tandem mass spectra. The accuracy and sensitivity of the identification software via database search are critical for successful proteomics experiments. A new database search tool, PEAKS DB, has been developed by incorporating the de novo sequencing results into the database search. PEAKS DB achieves significantly improved accuracy and sensitivity over two other commonly used software packages. Additionally, a new result validation method, decoy fusion, has been introduced to solve the issue of overconfidence that exists in the conventional target decoy method for certain types of peptide identification software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 8×
“The CID data set was searched against the P. aeruginosa database by Mascot, SEQUEST, and PEAKS DB.”
MethodInfluentialAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
TANDEM: matching proteins with tandem mass spectra
Craig, R., & Beavis, R. C. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth092 · Cited by 2,536
Open Mass Spectrometry Search Algorithm
Geer, L. Y., Markey, S. P., Kowalak, J. A., Wagner, L., Xu, M., Maynard, D. M., Yang, X., Shi, W., & Bryant, S. H. (2004) · Journal of Proteome Research · doi:10.1021/pr0499491 · Cited by 1,431
PEAKS: powerful software for peptide de novo sequencing by tandem mass spectrometry
Ma, B., Zhang, K., Hendrie, C., Liang, C., Li, M., Doherty‐Kirby, A., & Lajoie, G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1196 · Cited by 1,379
Self-citationPepNovo: De Novo Peptide Sequencing via Probabilistic Network Modeling
Frank, A., & Pevzner, P. (2005) · Analytical Chemistry · doi:10.1021/ac048788h · Cited by 688
Assigning Significance to Peptides Identified by Tandem Mass Spectrometry Using Decoy Databases
Käll, L., Storey, J. D., MacCoss, M. J., & Noble, W. S. (2008) · Journal of Proteome Research · doi:10.1021/pr700600n · Cited by 607
Accurate and Sensitive Peptide Identification with Mascot Percolator
Brosch, M., Yu, L., Hubbard, T., & Choudhary, J. (2009) · Journal of Proteome Research · doi:10.1021/pr800982s · Cited by 428
Sequence database searches viade novo peptide sequencing by tandem mass spectrometry
Taylor, J. A., & Johnson, R. S. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970615)11:9<1067::aid-rcm953>3.0.co;2-l · Cited by 414
A HUPO test sample study reveals common problems in mass spectrometry–based proteomics
HUPO Test Sample Working Group, Bell, A. W., Deutsch, E. W., Au, C. E., Kearney, R. E., Beavis, R., Sechi, S., Nilsson, T., & Bergeron, J. J. M. (2009) · Nature Methods · doi:10.1038/nmeth.1333 · Cited by 351
Kapp, E. A., Schütz, F., Connolly, L. M., Chakel, J. A., Meza, J. E., Miller, C. A., Fenyo, D., Eng, J. K., Adkins, J. N., Omenn, G. S., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200500126 · Cited by 344
Kim, S., Mischerikow, N., Bandeira, N., Navarro, J. D., Wich, L., Mohammed, S., Heck, A. J. R., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003731 · Cited by 226
NovoHMM: A Hidden Markov Model for de Novo Peptide Sequencing
Fischer, B., Roth, V., Roos, F., Grossmann, J., Baginsky, S., Widmayer, P., Gruissem, W., & Buhmann, J. M. (2005) · Analytical Chemistry · doi:10.1021/ac0508853 · Cited by 192
Chalkley, R. J., Baker, P. R., Huang, L., Hansen, K. C., Allen, N. P., Rexach, M., & Burlingame, A. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.d500002-mcp200 · Cited by 179
Protein abundances are more conserved than mRNA abundances across diverse taxa
Laurent, J. M., Vogel, C., Kwon, T., Craig, S. A., Boutz, D. R., Huse, H. K., Nozue, K., Walia, H., Whiteley, M., Ronald, P. C., et al. (2010) · PROTEOMICS · doi:10.1002/pmic.201000327 · Cited by 156
Chalkley, R. J., Baker, P. R., Hansen, K. C., Medzihradszky, K. F., Allen, N. P. C., Rexach, M. F., & Burlingame, A. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.d500001-mcp200 · Cited by 92
Reanalysis of Tyrannosaurus rex Mass Spectra
Bern, M., Phinney, B. S., & Goldberg, D. (2009) · Journal of Proteome Research · doi:10.1021/pr900349r · Cited by 58
Unbiased Statistical Analysis for Multi-Stage Proteomic Search Strategies
Everett, L. J., Bierl, C., & Master, S. R. (2009) · Journal of Proteome Research · doi:10.1021/pr900256v · Cited by 56
Better score function for peptide identification with ETD MS/MS spectra
Liu, X., Shan, B., Xin, L., & Ma, B. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-s1-s4 · Cited by 48
Self-citationSun, R.-X., Dong, M., Song, C., Chi, H., Yang, B., Xiu, L., Li, T., Jing, Z., Liu, C., Wang, L., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr100648r · Cited by 40
Comment on “Unbiased Statistical Analysis for Multi-Stage Proteomic Search Strategies”
Bern, M. W., & Kil, Y. J. (2011) · Journal of Proteome Research · doi:10.1021/pr101143m · Cited by 38
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationThe Skyline ecosystem: Informatics for quantitative mass spectrometry proteomics
Pino, L. K., Searle, B. C., Bollinger, J. G., Nunn, B., MacLean, B., & MacCoss, M. J. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21540 · Cited by 800
Trophoblast organoids as a model for maternal–fetal interactions during human placentation
Turco, M. Y., Gardner, L., Kay, R. G., Hamilton, R. S., Prater, M., Hollinshead, M. S., McWhinnie, A., Esposito, L., Fernando, R., Skelton, H., et al. (2018) · Nature · doi:10.1038/s41586-018-0753-3 · Cited by 694
Noncoding regions are the main source of targetable tumor-specific antigens
Laumont, C. M., Vincent, K., Hesnard, L., Audemard, É., Bonneil, É., Laverdure, J.-P., Gendron, P., Courcelles, M., Hardy, M.-P., Côté, C., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aau5516 · Cited by 535
FDR-controlled metabolite annotation for high-resolution imaging mass spectrometry
Palmer, A., Phapale, P., Chernyavsky, I., Lavigne, R., Fay, D., Tarasov, A., Kovalev, V., Fuchser, J., Nikolenko, S., Pineau, C., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4072 · Cited by 509
Metadata
- Authors
- Zhang, J., Xin, L., Shan, B., Chen, W., Xie, M., Yuen, D., Zhang, W., Zhang, Z., Lajoie, G. A., & Ma, B.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2012-04
- Volume
- 11
- Issue
- 4
- Pages
- M111.010587
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2135078307
- Cited by
- 1,081
- References
- 25
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.