Cross-linking immunoprecipitation-MS (xIP-MS): Topological Analysis of Chromatin-associated Protein Complexes Using Single Affinity Purification
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In recent years, cross-linking mass spectrometry has proven to be a robust and effective method of interrogating macromolecular protein complex topologies at peptide resolution. Traditionally, cross-linking mass spectrometry workflows have utilized homogenous complexes obtained through time-limiting reconstitution, tandem affinity purification, and conventional chromatography workflows. Here, we present cross-linking immunoprecipitation-MS (xIP-MS), a simple, rapid, and efficient method for structurally probing chromatin-associated protein complexes using small volumes of mammalian whole cell lysates, single affinity purification, and on-bead cross-linking followed by LC-MS/MS analysis. We first benchmarked xIP-MS using the structurally well-characterized phosphoribosyl pyrophosphate synthetase complex. We then applied xIP-MS to the chromatin-associated cohesin (SMC1A/3), XRCC5/6 (Ku70/86), and MCM complexes, and we provide novel structural and biological insights into their architectures and molecular function. Of note, we use xIP-MS to perform topological studies under cell cycle perturbations, showing that the xIP-MS protocol is sufficiently straightforward and efficient to allow comparative cross-linking experiments. This work, therefore, demonstrates that xIP-MS is a robust, flexible, and widely applicable methodology for interrogating chromatin-associated protein complex architectures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180 · cited 2×
“In our case, this involved identification of stable, specific interactors by LFQ analysis (22, 39).”
MethodQuantitative proteomics combined with BAC TransgeneOmics reveals in vivo protein interactions
Hubner, N. C., Bird, A. W., Cox, J., Splettstoesser, B., Bandilla, P., Poser, I., Hyman, A., & Mann, M. (2010) · Journal of Cell Biology · doi:10.1083/jcb.200911091 · Cited by 440 · cited 1×
“Cell Culture and Lysate Collection—Cell lysates were collected from stably transgenic HeLa Kyoto cells expressing near-endogenous levels of GFP-tagged bait protein from a recombined BAC transgene system (24, 25).”
MethodAffinity-purification coupled to mass spectrometry: basic principles and strategies
Dunham, W. H., Mullin, M., & Gingras, A. (2012) · PROTEOMICS · doi:10.1002/pmic.201100523 · Cited by 368 · cited 1×
“Single-AP-MS strategies are commonly applied in chromatin biology, where specific interactors can be identified in the presence of a vast amount of background proteins (2, 3, 21–23).”
BackgroundxiNET: cross-link network maps with residue resolution
Combe, C. W., Fischer, L., & Rappsilber, J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.042259 · Cited by 296 · cited 1×
“Cross-link maps were produced with xiNet, and distance constraints were analyzed with Xlink Analyzer in UCSF Chimera [41-43].”
MethodSmits, A. H., Jansen, P. W. T. C., Poser, I., Hyman, A. A., & Vermeulen, M. (2013) · Nucleic Acids Research · doi:10.1093/nar/gks941 · Cited by 258 · cited 2×
“In our case, this involved identification of stable, specific interactors by LFQ analysis (22, 39).”
MethodSelf-citationKloet, S. L., Baymaz, H. I., Makowski, M., Groenewold, V., Jansen, P. W. T. C., Berendsen, M., Niazi, H., Kops, G. J., & Vermeulen, M. (2015) · The FEBS Journal · doi:10.1111/febs.12972 · Cited by 107 · cited 1×
“For example, reconstitution of complexes to near homogeneity using tandem tagging systems has been previously reported, using a variety of tagging combinations (13, 15, 16).”
MethodSelf-citation
Cited by
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Chen, Z.-L., Meng, J.-M., Cao, Y., Yin, J.-L., Fang, R.-Q., Fan, S.-B., Liu, C., Zeng, W.-F., Ding, Y.-H., Tan, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11337-z · Cited by 552
O’Reilly, F. J., & Rappsilber, J. (2018) · Nature Structural & Molecular Biology · doi:10.1038/s41594-018-0147-0 · Cited by 360
Cross-Linking Mass Spectrometry: An Emerging Technology for Interactomics and Structural Biology
Yu, C., & Huang, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04431 · Cited by 353
Characterizing Protein–Protein Interactions Using Mass Spectrometry: Challenges and Opportunities
Smits, A. H., & Vermeulen, M. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.02.014 · Cited by 167
Self-citation
Metadata
- Authors
- Makowski, M. M., Willems, E., Jansen, P. W. T. C., & Vermeulen, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2016-03
- Volume
- 15
- Issue
- 3
- Pages
- 854-865
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2312121172
- Cited by
- 57
- References
- 6
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.