High Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The detection and quantification of plasma (serum) proteins at or below the ng/ml concentration range are of critical importance for the discovery and evaluation of new protein biomarkers. This has been achieved either by the development of high sensitivity ELISA or other immunoassays for specific proteins or by the extensive fractionation of the plasma proteome followed by the mass spectrometric analysis of the resulting fractions. The first approach is limited by the high cost and time investment for assay development and the requirement of a validated target. The second, although reasonably comprehensive and unbiased, is limited by sample throughput. Here we describe a method for the detection of plasma proteins at concentrations in the ng/ml or sub-ng/ml range and their accurate quantification over 5 orders of magnitude. The method is based on the selective isolation of N-glycosites from the plasma proteome and the detection and quantification of targeted peptides in a quadrupole linear ion trap instrument operated in the multiple reaction monitoring (MRM) mode. The unprecedented sensitivity of the mass spectrometric analysis of minimally fractionated plasma samples is the result of the significantly reduced sample complexity of the isolated N-glycosites compared with whole plasma proteome digests and the selectivity of the MRM process. Precise quantification was achieved via stable isotope dilution by adding (13)C- and/or (15)N-labeled reference analytes. We also demonstrate the possibility of significantly expanding the number of MRM measurements during one single LC-MS run without compromising sensitivity by including elution time constraints for the targeted transitions, thus allowing quantification of large sets of peptides in a single analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
On the frequency of protein glycosylation, as deduced from analysis of the SWISS-PROT database
Apweiler, R. (1999) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(99)00165-8 · Cited by 1,855
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 1×
“thus facilitating precise quantification (20).”
Spiro, R. G. (2002) · Glycobiology · doi:10.1093/glycob/12.4.43r · Cited by 1,409
Zhang, H., Li, X.-J., Martin, D. B., & Aebersold, R. (2003) · Nature Biotechnology · doi:10.1038/nbt827 · Cited by 1,389
Self-citationMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Self-citationQuantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230 · cited 2×
“5 g/ml limits reported after affinity enrichment of selected peptides from whole plasma digests using the stable isotope standards and capture by anti-peptide antibodies (SISCAPA) method or by analyzing plasma samples depleted for the six highest abundance proteins (9).”
BackgroundMethodOmenn, G. S., States, D. J., Adamski, M., Blackwell, T. W., Menon, R., Hermjakob, H., Apweiler, R., Haab, B. B., Simpson, R. J., Eddes, J. S., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200500358 · Cited by 787
Self-citationPratt, J. M., Simpson, D. M., Doherty, M. K., Rivers, J., Gaskell, S. J., & Beynon, R. J. (2006) · Nature Protocols · doi:10.1038/nprot.2006.129 · Cited by 373
A list of candidate cancer biomarkers for targeted proteomics.
Polanski, M., & Anderson, N. L. (2007) · PubMed Central · Cited by 350
States, D. J., Omenn, G. S., Blackwell, T. W., Fermin, D., Eng, J., Speicher, D. W., & Hanash, S. M. (2006) · Nature Biotechnology · doi:10.1038/nbt1183 · Cited by 325
A List of Candidate Cancer Biomarkers for Targeted Proteomics
Polanski, M., & Anderson, N. L. (2006) · Biomarker Insights · doi:10.1177/117727190600100001 · Cited by 189
Mass Spectrometric Detection of Tissue Proteins in Plasma
Zhang, H., Liu, A. Y., Loriaux, P., Wollscheid, B., Zhou, Y., Watts, J. D., & Aebersold, R. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600160-mcp200 · Cited by 180
Self-citationHigh Dynamic Range Characterization of the Trauma Patient Plasma Proteome
Liu, T., Qian, W.-J., Gritsenko, M. A., Xiao, W., Moldawer, L. L., Kaushal, A., Monroe, M. E., Varnum, S. M., Moore, R. J., Purvine, S. O., et al. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600068-mcp200 · Cited by 160
Blanc, J. C. Y. L., Hager, J. W., Ilisiu, A. M. P., Hunter, C. L., Zhong, F., & Chu, I. K. (2003) · PROTEOMICS · doi:10.1002/pmic.200300415 · Cited by 147
Biases and complex patterns in the residues flanking protein N-glycosylation sites
Ben‐Dor, S., Esterman, N., Rubin, E., & Sharon, N. (2003) · Glycobiology · doi:10.1093/glycob/cwh004 · Cited by 143
High Throughput Proteome Screening for Biomarker Detection
Pan, S., Zhang, H., Rush, A. J., Eng, J. K., Zhang, N., Patterson, D. H., Comb, M. J., & Aebersold, R. H. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400161-mcp200 · Cited by 143
Self-citationDeutsch, E. W., Eng, J. K., Zhang, H., King, N. L., Nesvizhskii, A. I., Lin, B., Lee, H., Yi, E. C., Ossola, R., & Aebersold, R. (2005) · PROTEOMICS · doi:10.1002/pmic.200500160 · Cited by 141
Self-citationStructural elucidation of drug metabolites by triple-quadrupole mass spectrometry
Perchalski, R. J., Yost, R. A., & Wilder, B. J. (1982) · Analytical Chemistry · doi:10.1021/ac00246a006 · Cited by 101
Li, X., Pedrioli, P. G. A., Eng, J. K., Martin, D. B., Yi, E. C., Lee, H., & Aebersold, R. H. (2004) · Analytical Chemistry · doi:10.1021/ac035375s · Cited by 91
Self-citation
Cited by
Selected reaction monitoring for quantitative proteomics: a tutorial
Lange, V., Picotti, P., Domon, B., & Aebersold, R. (2008) · Molecular Systems Biology · doi:10.1038/msb.2008.61 · Cited by 1,407
Self-citationSelected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Self-citationMining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
Self-citation
Metadata
- Authors
- Stahl-Zeng, J., Lange, V., Ossola, R., Eckhardt, K., Krek, W., Aebersold, R., & Domon, B.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2007-10
- Volume
- 6
- Issue
- 10
- Pages
- 1809-1817
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2108401997
- Cited by
- 361
- References
- 21
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.