The DOI matches its Crossref record.
SIMAC (Sequential Elution from IMAC), a Phosphoproteomics Strategy for the Rapid Separation of Monophosphorylated from Multiply Phosphorylated Peptides
Open accessAbstract
The complete analysis of phosphoproteomes has been hampered by the lack of methods for efficient purification, detection, and characterization of phosphorylated peptides from complex biological samples. Despite several strategies for affinity enrichment of phosphorylated peptides prior to mass spectrometric analysis, such as immobilized metal affinity chromatography or titanium dioxide, the coverage of the phosphoproteome of a given sample is limited. Here we report a simple and rapid strategy, SIMAC (sequential elution from IMAC), for sequential separation of monophosphorylated peptides and multiply phosphorylated peptides from highly complex biological samples. This allows individual analysis of the two pools of phosphorylated peptides using mass spectrometric parameters differentially optimized for their unique properties. We compared the phosphoproteome identified from 120 mug of human mesenchymal stem cells using SIMAC and an optimized titanium dioxide chromatographic method. More than double the total number of identified phosphorylation sites was obtained with SIMAC, primarily from a 3-fold increase in recovery of multiply phosphorylated peptides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Zhao, Y., & Jensen, O. N. (2009) · PROTEOMICS · doi:10.1002/pmic.200900398 · Cited by 384
Self-citationGundry, R. L., White, M. Y., Murray, C. I., Kane, L. A., Fu, Q., Stanley, B. A., & Van Eyk, J. E. (2010) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb1025s88 · Cited by 306
Mass Spectrometry-Based Detection and Assignment of Protein Posttranslational Modifications
Doll, S., & Burlingame, A. L. (2015) · ACS Chemical Biology · doi:10.1021/cb500904b · Cited by 261
Catch me if you can: Mass spectrometry‐based phosphoproteomics and quantification strategies
Eyrich, B., Sickmann, A., & Zahedi, R. P. (2011) · PROTEOMICS · doi:10.1002/pmic.201000489 · Cited by 104
Metadata
- Authors
- Thingholm, T. E., Jensen, O. N., Robinson, P. J., & Larsen, M. R.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 7
- Issue
- 4
- Pages
- 661-671
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2063186742
- Cited by
- 425
- References
- 0
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SIMAC (Sequential Elution from IMAC), a Phosphoproteomics Strategy for the Rapid Separation of Monophosphorylated from Multiply Phosphorylated Peptides. https://app.cochat.ai/papers/10.1074/mcp.m700362-mcp200
- The paper
- Thingholm, T. E., Jensen, O. N., Robinson, P. J., & Larsen, M. R. (2008). SIMAC (Sequential Elution from IMAC), a Phosphoproteomics Strategy for the Rapid Separation of Monophosphorylated from Multiply Phosphorylated Peptides. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m700362-mcp200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.