Sensitive and Specific Identification of Wild Type and Variant Proteins from 8 to 669 kDa Using Top-down Mass Spectrometry
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Top-down and bottom-up mass spectrometry methods can generate gas phase fragments and use these to identify proteins. Top-down methods, in addition, can provide the mass of the protein itself and therefore additional structural information. Despite the conceptual advantage of top-down methods, the market share advantage belongs to bottom-up methods as a result of their more robust sample preparation, fragmentation, and data processing methods. Here we report improved fragmentation and data processing methods for top-down mass spectrometry. Specifically we report the use of funnel-skimmer dissociation, a variation of nozzle-skimmer dissociation, and compare its performance with electron capture dissociation. We also debut BIG Mascot, an extended version of Mascot with incorporated top-down MS(2) search ability and the first search engine that can perform both bottom-up and top-down searches. Using BIG Mascot, we demonstrated the ability to identify proteins 1) using only intact protein MS(1), 2) using only MS(2), and 3) using the combination of MS(1) and MS(2). We correctly identified proteins with a wide range of masses, including 13 amyotrophic lateral sclerosis-associated variants of the protein Cu/Zn-superoxide dismutase, and extended the upper mass limit of top-down protein identification to 669 kDa by identifying thyroglobulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“Ionization and detection of intact proteins have been possible for 20 years (1, 2).”
BackgroundPeptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 1×
“Recent improvements in these areas include the following: 1) separation techniques compatible with top-down analysis (18, 32); 2) fragmentation techniques, including nozzle-skimmer dissociation (3, 33–35), electron transfer dissociation (7, 8), prefolding dissociation (9), and activated ion electron capture dissociati…”
MethodElectron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 1×
“SNAP uses a given mass, charge, and mean molecular constitution (in our case averagine (52)) to calculate isotopic distribution to obtain a nonlinear fit to the data in a similar fashion to the THRASH (thorough high resolution analysis of spectra by Horn) algorithm introduced by Horn et al.”
MethodProtein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373 · cited 1×
“Recent improvements in these areas include the following: 1) separation techniques compatible with top-down analysis (18, 32); 2) fragmentation techniques, including nozzle-skimmer dissociation (3, 33–35), electron transfer dissociation (7, 8), prefolding dissociation (9), and activated ion electron capture dissociati…”
MethodExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Patrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500219-mcp200 · Cited by 62
Cited by
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Li, H., Nguyen, H. H., Ogorzalek Loo, R. R., Campuzano, I. D. G., & Loo, J. A. (2018) · Nature Chemistry · doi:10.1038/nchem.2908 · Cited by 249
Protein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Metadata
- Authors
- Karabacak, N. M., Li, L., Tiwari, A., Hayward, L. J., Hong, P., Easterling, M. L., & Agar, J. N.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 8
- Issue
- 4
- Pages
- 846-856
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2117262948
- Cited by
- 96
- References
- 7
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive and Specific Identification of Wild Type and Variant Proteins from 8 to 669 kDa Using Top-down Mass Spectrometry. https://app.cochat.ai/papers/10.1074/mcp.m800099-mcp200
- The paper
- Karabacak, N. M., Li, L., Tiwari, A., Hayward, L. J., Hong, P., Easterling, M. L., & Agar, J. N. (2009). Sensitive and Specific Identification of Wild Type and Variant Proteins from 8 to 669 kDa Using Top-down Mass Spectrometry. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m800099-mcp200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.