Clinical Quantitation of Prostate-specific Antigen Biomarker in the Low Nanogram/Milliliter Range by Conventional Bore Liquid Chromatography-Tandem Mass Spectrometry (Multiple Reaction Monitoring) Coupling and Correlation with ELISA Tests
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Proteomics discovery leads to a list of potential protein biomarkers that have to be subsequently verified and validated with a statistically viable number of patients. Although the most sensitive, the development of an ELISA test is time-consuming when antibodies are not available and need to be conceived. Mass spectrometry analysis driven in quantitative multiple reaction monitoring mode is now appearing as a promising alternative to quantify proteins in biological fluids. However, all the studies published to date describe limits of quantitation in the low microg/ml range when no immunoenrichment of the target protein is applied, whereas the concentration of known clinical biomarkers is usually in the ng/ml range. Using prostate-specific antigen as a model biomarker, we now provide proof of principle that mass spectrometry enables protein quantitation in a concentration range of clinical interest without immunoenrichment. We have developed and optimized a robust sample processing method combining albumin depletion, trypsin digestion, and solid phase extraction of the proteotypic peptides starting from only 100 microl of serum. For analysis, mass spectrometry was coupled to a conventional liquid chromatography system using a 2-mm-internal diameter reverse phase column. This mass spectrometry-based strategy was applied to the quantitation of prostate-specific antigen in sera of patients with either benign prostate hyperplasia or prostate cancer. The quantitation was performed against an external calibration curve by interpolation, and results showed good correlation with existing ELISA tests applied to the same samples. This strategy might now be implemented in any clinical laboratory or certified company for further evaluation of any putative biomarker in the low ng/ml range of serum or plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 2×
“synthetic stable isotope-labeled isotopomer (2).”
MethodQuantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230 · cited 3×
“In a pioneering study Anderson and Hunter (3) successfully demonstrated generation of a multiplexed assay for proteins covering high (tens to hundreds of micrograms/milliliter) to medium (hundreds of nanograms/milliliter to a few micrograms/milliliter) abundance ranges in plasma when combined with immunodepletion.”
InfluentialComputational prediction of proteotypic peptides for quantitative proteomics
Mallick, P., Schirle, M., Chen, S. S., Flory, M. R., Lee, H., Martin, D., Ranish, J., Raught, B., Schmitt, R., Werner, T., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1275 · Cited by 695 · cited 1×
“tively, to a proteotypic peptide (1) obtained from enzymatic”
BackgroundKeshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700354-mcp200 · Cited by 684 · cited 4×
“(4) even after peptide fractionation, we did not notice any interference in the most intense 636.”
BackgroundInfluentialIsotope-labeled Protein Standards
Brun, V., Dupuis, A., Adrait, A., Marcellin, M., Thomas, D., Court, M., Vandenesch, F., & Garin, J. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700163-mcp200 · Cited by 445
Kuhn, E., Wu, J., Karl, J., Liao, H., Zolg, W., & Guild, B. (2004) · PROTEOMICS · doi:10.1002/pmic.200300670 · Cited by 398 · cited 1×
“method (23) QCAT also led to underestimation of the target”
MethodPratt, J. M., Simpson, D. M., Doherty, M. K., Rivers, J., Gaskell, S. J., & Beynon, R. J. (2006) · Nature Protocols · doi:10.1038/nprot.2006.129 · Cited by 373 · cited 1×
“QCAT strategy proposed by Beynon and co-workers (21), an”
MethodMolecular forms of prostate-specific antigen and the human kallikrein gene family: A new era
McCormack, R. T., Wang, T. J., Rittenhouse, H. G., Wolfert, R. L., Finlay, J. A., Lilja, H., Okoloff, R. L., & Oesterling, J. E. (1995) · Urology · doi:10.1016/s0090-4295(99)80076-4 · Cited by 303 · cited 1×
“In blood, PSA can remain free or be complexed with several protease inhibitors (PSA ACT or PSA 2M) (15).”
BackgroundWhiteaker, J. R., Zhao, L., Zhang, H. Y., Feng, L.-C., Piening, B. D., Anderson, L., & Paulovich, A. G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2006.12.023 · Cited by 270
Barnidge, D. R., Goodmanson, M. K., Klee, G. G., & Muddiman, D. C. (2004) · Journal of Proteome Research · doi:10.1021/pr049963d · Cited by 253 · cited 1×
“Hence the lowest limit of quantitation of a protein in non-depleted serum is reported around the g/ml range (11), whereas an MS-based clinically relevant assay of PSA should span LOQ in the low ng/ml range.”
BackgroundAlbumin depletion of human plasma also removes low abundance proteins including the cytokines
Granger, J., Siddiqui, J., Copeland, S., & Remick, D. (2005) · PROTEOMICS · doi:10.1002/pmic.200401331 · Cited by 228 · cited 1×
“This result is not really surprising because previous studies (12) have already mentioned the nonspecific binding of numerous proteins such as the low abundance cytokines (13).”
ResultEfficient and Specific Removal of Albumin from Human Serum Samples
Steel, L. F., Trotter, M. G., Nakajima, P. B., Mattu, T. S., Gonye, G., & Block, T. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300026-mcp200 · Cited by 212
Whiteaker, J. R., Zhang, H., Zhao, L., Wang, P., Kelly-Spratt, K. S., Ivey, R. G., Piening, B. D., Feng, L.-C., Kasarda, E., Gurley, K. E., et al. (2007) · Journal of Proteome Research · doi:10.1021/pr070202v · Cited by 179
Oe, T., Ackermann, B. L., Inoue, K., Berna, M. J., Garner, C. O., Gelfanova, V., Dean, R. A., Siemers, E. R., Holtzman, D. M., Farlow, M. R., et al. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2787 · Cited by 166
Wu, S.-L., Amato, H., Biringer, R., Choudhary, G., Shieh, P., & Hancock, W. S. (2002) · Journal of Proteome Research · doi:10.1021/pr025537l · Cited by 123
Lin, S., Shaler, T. A., & Becker, C. H. (2006) · Analytical Chemistry · doi:10.1021/ac060613f · Cited by 87
“Product Ion Monitoring” Assay for Prostate-Specific Antigen in Serum Using a Linear Ion-Trap
Kulasingam, V., Smith, C. R., Batruch, I., Buckler, A., Jeffery, D. A., & Diamandis, E. P. (2008) · Journal of Proteome Research · doi:10.1021/pr7005999 · Cited by 86 · cited 1×
“by Diamandis and co-workers (5) that allowed reaching a limit”
BackgroundZhang, W., Finne, P., Leinonen, J., Vesalainen, S., Nordling, S., Rannikko, S., & Stenman, U. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2471 · Cited by 81 · cited 1×
“(17) the concentration of PSA 2M complex in serum is correlated with that of total PSA and, on average, accounts for 10% of serum PSA.”
Background
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Quantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry
Gillette, M. A., & Carr, S. A. (2013) · Nature Methods · doi:10.1038/nmeth.2309 · Cited by 495
Targeted Quantitation of Proteins by Mass Spectrometry
Liebler, D. C., & Zimmerman, L. J. (2013) · Biochemistry · doi:10.1021/bi400110b · Cited by 363
Metadata
- Authors
- Fortin, T., Salvador, A., Charrier, J. P., Lenz, C., Lacoux, X., Morla, A., Choquet-Kastylevsky, G., & Lemoine, J.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 8
- Issue
- 5
- Pages
- 1006-1015
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2157266522
- Cited by
- 177
- References
- 18
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.