Large Scale Localization of Protein Phosphorylation by Use of Electron Capture Dissociation Mass Spectrometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We used on-line electron capture dissociation (ECD) for the large scale identification and localization of sites of phosphorylation. Each FT-ICR ECD event was paired with a linear ion trap collision-induced dissociation (CID) event, allowing a direct comparison of the relative merits of ECD and CID for phosphopeptide identification and site localization. Linear ion trap CID was shown to be most efficient for phosphopeptide identification, whereas FT-ICR ECD was superior for localization of sites of phosphorylation. The combination of confident CID and ECD identification and confident CID and ECD localization is particularly valuable in cases where a phosphopeptide is identified just once within a phosphoproteomics experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 1×
“obtained in ion trap mass spectrometers (19).”
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Beausoleil, S. A., Villén, J., Gerber, S. A., Rush, J., & Gygi, S. P. (2006) · Nature Biotechnology · doi:10.1038/nbt1240 · Cited by 1,577
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Phosphopeptide fragmentation and analysis by mass spectrometry
Boersema, P. J., Mohammed, S., & Heck, A. J. R. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1599 · Cited by 362
Exploring the caves: cavins, caveolins and caveolae
Hansen, C. G., & Nichols, B. J. (2010) · Trends in Cell Biology · doi:10.1016/j.tcb.2010.01.005 · Cited by 295
Catch me if you can: Mass spectrometry‐based phosphoproteomics and quantification strategies
Eyrich, B., Sickmann, A., & Zahedi, R. P. (2011) · PROTEOMICS · doi:10.1002/pmic.201000489 · Cited by 104
“In general, CID seems to be most efficient for phosphopeptide identification [103], whereas ECD and ETD are superior for localization of phosphorylation sites [104].”
BackgroundSun, Y.-N., Huang, J.-Q., Chen, Z.-Z., Du, M., Ren, F.-Z., Luo, J., & Fang, B. (2020) · The Journal of Nutrition · doi:10.1093/jn/nxz236 · Cited by 22
Metadata
- Authors
- Sweet, S. M. M., Bailey, C. M., Cunningham, D. L., Heath, J. K., & Cooper, H. J.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 8
- Issue
- 5
- Pages
- 904-912
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2034652638
- Cited by
- 84
- References
- 3
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large Scale Localization of Protein Phosphorylation by Use of Electron Capture Dissociation Mass Spectrometry. https://app.cochat.ai/papers/10.1074/mcp.m800451-mcp200
- The paper
- Sweet, S. M. M., Bailey, C. M., Cunningham, D. L., Heath, J. K., & Cooper, H. J. (2009). Large Scale Localization of Protein Phosphorylation by Use of Electron Capture Dissociation Mass Spectrometry. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m800451-mcp200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.