Analysis of 1508 Plasma Samples by Capillary-Flow Data-Independent Acquisition Profiles Proteomics of Weight Loss and Maintenance
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Comprehensive, high throughput analysis of the plasma proteome has the potential to enable holistic analysis of the health state of an individual. Based on our own experience and the evaluation of recent large-scale plasma mass spectrometry (MS) based proteomic studies, we identified two outstanding challenges: slow and delicate nano-flow liquid chromatography (LC) and irreproducibility of identification of data-dependent acquisition (DDA). We determined an optimal solution reducing these limitations with robust capillary-flow data-independent acquisition (DIA) MS. This platform can measure 31 plasma proteomes per day. Using this setup, we acquired a large-scale plasma study of the diet, obesity and genes dietary (DiOGenes) comprising 1508 samples. Proving the robustness, the complete acquisition was achieved on a single analytical column. Totally, 565 proteins (459 identified with two or more peptide sequences) were profiled with 74% data set completeness. On average 408 proteins (5246 peptides) were identified per acquisition (319 proteins in 90% of all acquisitions). The workflow reproducibility was assessed using 34 quality control pools acquired at regular intervals, resulting in 92% data set completeness with CVs for protein measurements of 10.9%.The profiles of 20 apolipoproteins could be profiled revealing distinct changes. The weight loss and weight maintenance resulted in sustained effects on low-grade inflammation, as well as steroid hormone and lipid metabolism, indicating beneficial effects. Comparison to other large-scale plasma weight loss studies demonstrated high robustness and quality of biomarker candidates identified. Tracking of nonenzymatic glycation indicated a delayed, slight reduction of glycation in the weight maintenance phase. Using stable-isotope-references, we could directly and absolutely quantify 60 proteins in the DIA.In conclusion, we present herein the first large-scale plasma DIA study and one of the largest clinical research proteomic studies to date. Application of this fast and robust workflow has great potential to advance biomarker discovery in plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855 · cited 1×
“The DDA spectra were analyzed with the MaxQuant (Version 1.6.0.1) software (32) with default settings using the Andromeda search engine (33).”
InfluentialStatistical significance for genomewide studies
Storey, J. D., & Tibshirani, R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1530509100 · Cited by 9,692 · cited 5×
“1 The abbreviations used are: FDA, Food and Drug Administration; CV, coefficient of variation; DDA, data-dependent acquisition; DIA, data-independent acquisition; FDR, false discovery rate; MS1, peptide precursor survey scan; MS2, fragment ion scan; CID, clinical investigation day; LCD, low-calorie diet; WMD, weight m…”
InfluentialEckel, R. H., Alberti, K., Grundy, S. M., & Zimmet, P. Z. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61794-3 · Cited by 6,295
Causal analysis approaches in Ingenuity Pathway Analysis
Krämer, A., Green, J., Pollard, J., & Tugendreich, S. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btt703 · Cited by 5,724 · cited 4×
“Protein pathway analysis using IPA (40) indicated activated lipid metabolism and increased concentrations of cholesterol and (tri)acylglycerols.”
MethodInfluentialEckel, R. H., Grundy, S. M., & Zimmet, P. Z. (2005) · The Lancet · doi:10.1016/s0140-6736(05)66378-7 · Cited by 5,550
Andromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500 · cited 1×
“The DDA spectra were analyzed with the MaxQuant (Version 1.6.0.1) software (32) with default settings using the Andromeda search engine (33).”
InfluentialYamauchi, T., Kamon, J., Waki, H., Terauchi, Y., Kubota, N., Hara, K., Mori, Y., Ide, T., Murakami, K., Tsuboyama-Kasaoka, N., et al. (2001) · Nature Medicine · doi:10.1038/90984 · Cited by 4,915 · cited 1×
“) the adipokine adiponectin remained elevated in weight maintenance, it is involved in the control of fat metabolism and insulin sensitivity (53); (2.”
2016 update of the PRIDE database and its related tools
Vizcaíno, J. A., Csordas, A., del-Toro, N., Dianes, J. A., Griss, J., Lavidas, I., Mayer, G., Perez-Riverol, Y., Reisinger, F., Ternent, T., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv1145 · Cited by 3,451
Cardiovascular effects of intensive lifestyle intervention in type 2 diabetes
The Look AHEAD Research Group (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1212914 · Cited by 2,908
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334 · cited 1×
“The technological ability of MS-based proteomics has drastically improved over the last several years (16–19).”
Cited by
Ultra-High-Throughput Clinical Proteomics Reveals Classifiers of COVID-19 Infection
Messner, C. B., Demichev, V., Wendisch, D., Michalick, L., White, M., Freiwald, A., Textoris-Taube, K., Vernardis, S. I., Egger, A.-S., Kreidl, M., et al. (2020) · Cell Systems · doi:10.1016/j.cels.2020.05.012 · Cited by 561
Genetics meets proteomics: perspectives for large population-based studies
Suhre, K., McCarthy, M. I., & Schwenk, J. M. (2021) · Nature Reviews Genetics · doi:10.1038/s41576-020-0268-2 · Cited by 478
Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS
Bian, Y., Zheng, R., Bayer, F. P., Wong, C., Chang, Y.-C., Meng, C., Zolg, D. P., Reinecke, M., Zecha, J., Wiechmann, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13973-x · Cited by 345
Zhang, F., Ge, W., Ruan, G., Cai, X., & Guo, T. (2020) · PROTEOMICS · doi:10.1002/pmic.201900276 · Cited by 343
Ultra-fast proteomics with Scanning SWATH
Messner, C. B., Demichev, V., Bloomfield, N., Yu, J. S. L., White, M., Kreidl, M., Egger, A.-S., Freiwald, A., Ivosev, G., Wasim, F., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00860-4 · Cited by 308
Advances and Utility of the Human Plasma Proteome
Deutsch, E. W., Omenn, G. S., Sun, Z., Maes, M., Pernemalm, M., Palaniappan, K. K., Letunica, N., Vandenbrouck, Y., Brun, V., Tao, S.-C., et al. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00657 · Cited by 246
Ignjatovic, V., Geyer, P. E., Palaniappan, K. K., Chaaban, J. E., Omenn, G. S., Baker, M. S., Deutsch, E. W., & Schwenk, J. M. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00503 · Cited by 229
Petrera, A., von Toerne, C., Behler, J., Huth, C., Thorand, B., Hilgendorff, A., & Hauck, S. M. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00641 · Cited by 216
Targeted and Untargeted Proteomics Approaches in Biomarker Development
Sobsey, C. A., Ibrahim, S., Richard, V. R., Gaspar, V., Mitsa, G., Lacasse, V., Zahedi, R. P., Batist, G., & Borchers, C. H. (2020) · PROTEOMICS · doi:10.1002/pmic.201900029 · Cited by 171
Kitata, R. B., Yang, J., & Chen, Y. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21781 · Cited by 165
Wang, S., Li, W., Hu, L., Cheng, J., Yang, H., & Liu, Y. (2020) · Nucleic Acids Research · doi:10.1093/nar/gkaa498 · Cited by 163
“For example, researchers have shown consistent detection of thousands of proteins between multiple clinical samples using TMT (1,2), and samples in even larger cohort sizes (i.e. > 100–1000s) us-ing library-based MS1 alignment (23) and DIA-MS (24,25).”
Vowinckel, J., Zelezniak, A., Kibler, A., Bruderer, R., Muelleder, M., Reiter, L., & Ralser, M. (2016) · doi:10.1101/073478 · Cited by 81
Self-citationSpatially resolved analysis of FFPE tissue proteomes by quantitative mass spectrometry
Buczak, K., Kirkpatrick, J. M., Truckenmueller, F., Santinha, D., Ferreira, L., Roessler, S., Singer, S., Beck, M., & Ori, A. (2020) · Nature Protocols · doi:10.1038/s41596-020-0356-y · Cited by 78
Salovska, B., Li, W., Di, Y., & Liu, Y. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04293 · Cited by 35
(2020) · doi:10.1101/2020.11.20.392043 · Cited by 35
Metadata
- Authors
- Bruderer, R., Muntel, J., Müller, S., Bernhardt, O. M., Gandhi, T., Cominetti, O., Macron, C., Carayol, J., Rinner, O., Astrup, A., Saris, W. H. M., Hager, J., Valsesia, A., Dayon, L., & Reiter, L.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 18
- Issue
- 6
- Pages
- 1242-1254
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2931155919
- Cited by
- 183
- References
- 63
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.