Large Scale Protein Profiling by Combination of Protein Fractionation and Multidimensional Protein Identification Technology (MudPIT)
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In the past decade, shotgun proteomic analysis has been utilized extensively to answer complex biological questions. New challenges arise in large scale proteomic profiling when dealing with complex biological mixtures such as the mammalian cell lysate. In this study, we explored the approach of protein separation prior to the shotgun multidimensional protein identification technology (MudPIT) analysis. We fractionated the mammalian cancer cell lysate using the PF 2D ProteomeLab system and analyzed the distribution of molecular weight, isoelectric point, and cellular localization of the eluted proteins. As a result, we were able to reduce sample complexity by protein fractionation and increase the possibility of detecting proteins with lower abundance in the complex protein mixture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 2×
“Interpretation of MS/MS Datasets—SEQUEST (1) was used to match MS/MS spectra to peptides in a database containing human sequences downloaded from the National Center for Biotechnology Information (NCBI) in July 2004.”
Self-citationLarge-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Self-citationDirect analysis of protein complexes using mass spectrometry
Link, A. J., Eng, J., Schieltz, D. M., Carmack, E., Mize, G. J., Morris, D. R., Garvik, B. M., & Yates, J. R. (1999) · Nature Biotechnology · doi:10.1038/10890 · Cited by 2,237
Self-citationTabb, D. L., McDonald, W. H., & Yates, J. R. (2002) · Journal of Proteome Research · doi:10.1021/pr015504q · Cited by 1,367 · cited 3×
“runs were compared using CONTRAST (2).”
MethodSelf-citationTwo-Dimensional SEC/RPLC Coupled to Mass Spectrometry for the Analysis of Peptides
Opiteck, G. J., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961156d · Cited by 278
Larmann, J. P., Lemmo, A. V., Moore, A. W., & Jorgenson, J. W. (1993) · Electrophoresis · doi:10.1002/elps.1150140169 · Cited by 115
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationFull dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
Proteomics: a pragmatic perspective
Mallick, P., & Kuster, B. (2010) · Nature Biotechnology · doi:10.1038/nbt.1658 · Cited by 430
Contribution of oncoproteomics to cancer biomarker discovery
Cho, W. C. (2007) · Molecular Cancer · doi:10.1186/1476-4598-6-25 · Cited by 268
Chen, S., & Harmon, A. C. (2006) · PROTEOMICS · doi:10.1002/pmic.200600143 · Cited by 255
High abundance synovial fluid proteome: distinct profiles in health and osteoarthritis
Gobezie, R., Kho, A., Krastins, B., Sarracino, D. A., Thornhill, T. S., Chase, M., Millett, P. J., & Lee, D. M. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2172 · Cited by 249
“These data coupled with the MudPIT (multidimensional protein identification technology) quantitation technique allows us to predict relative levels of protein expression within the context of a onedimensional gel compared with a two-dimensional gel, as previously described [12-14].”
MethodActivity-based probes as a tool for functional proteomic analysis of proteases
Fonović, M., & Bogyo, M. (2008) · Expert Review of Proteomics · doi:10.1586/14789450.5.5.721 · Cited by 231
Comparative LC‐MS: A landscape of peaks and valleys
America, A. H. P., & Cordewener, J. H. G. (2008) · PROTEOMICS · doi:10.1002/pmic.200700694 · Cited by 191
Accurate and Sensitive Quantitation of the Dynamic Heat Shock Proteome Using Tandem Mass Tags
(2020) · doi:10.1021/acs.jproteome.9b00704 · Cited by 13
Accurate and Sensitive Quantitation of the Dynamic Heat Shock Proteome using Tandem Mass Tags
Storey, A. J., Hardman, R. E., Byrum, S. D., Mackintosh, S. G., Edmondson, R. D., Wahls, W. P., Tackett, A. J., & Lewis, J. A. (2019) · doi:10.1101/696641 · Cited by 13
Metadata
- Authors
- Chen, E. I., Hewel, J., Felding-Habermann, B., & Yates, J. R.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2006-01
- Volume
- 5
- Issue
- 1
- Pages
- 53-56
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2128047935
- Cited by
- 175
- References
- 6
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.