Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The objective of the present study was to determine the accuracy of two foot-to-foot (FF) bioelectrical impedance analysers (BIA) to assess body composition in overweight and obese adolescents, compared with dual-energy X-ray absorptiometry (DXA) and hand-to-foot (HF) BIA. Body composition was assessed in fifty-three overweight or obese adolescents (BMI 27·9 (sd 4·1) kg/m 2; aged 13–16 years) by DXA (Hologic QDR-4500; Hologic Inc., Bedford, MA, USA) and BIA (HF (BIA 101, RJL System, Detroit, IL, USA) and FF (Body Fat Monitor Scale BF-625, Tanita Corporation of America Inc., Arlington Heights, IL, USA; Téfal Bodymaster Vision, Téfal, Rumilly, France)). Bland–Altman tests showed that, compared with DXA, FF-Tanita and FF-Téfal underestimated (P<0·05) fat mass (FM) less than HF-BIA (−1·7 (sd 3·1), −0·7 (sd 5·8) and −2·3 (sd 2·2) kg respectively, P<0·001). However, the limits of agreement between DXA and FF-Tanita or FF-Téfal were much greater than those obtained with HF-BIA (−7·7 and +4·3, −12·0 and +10·6 v. −2·1 and +6·7kg respectively). The differences between FM assessed using the FF-Tanita or the FF-Téfal analyser and DXA increased with the waist:hip ratio, and were higher in boys than in girls. The major limiting factor of FF-BIA was the inter-individual variability in FM estimates. In conclusion, FF-BIA and DXA are not interchangeable methods. FF-BIA could be acceptable to assess body composition in large groups of overweight or obese adolescents, but cannot be recommended for body composition assessment in obese subjects because of the large errors in individual estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.524s · Cited by 549
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429 · cited 3×
“British Journal of Nutrition (2003), 90, 987–992 DOI: 10.1079/BJN2003983 q The Authors 2003 subjects (Foster & Lukaski, 1996).”
BackgroundInfluentialEisenkölbl, J., Kartasurya, M., & Widhalm, K. (2001) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601184 · Cited by 115 · cited 3×
“Therefore, specific prediction equations should be used for obese subjects, because predictive equations developed in normal-weight subjects generally underestimate FM (Deurenberg, 1996) in obese adults and children (Ellis, 1996; Eisenkolbl et al. 2001).”
Background
Cited by
Alemzadeh, R., Kichler, J., Babar, G., & Calhoun, M. (2008) · Metabolism · doi:10.1016/j.metabol.2007.08.023 · Cited by 419
Bosy-Westphal, A., Later, W., Hitze, B., Sato, T., Kossel, E., Glüer, C.-C., Heller, M., & Müller, M. J. (2008) · Obesity Facts · doi:10.1159/000176061 · Cited by 263
Challenges of Accurately Measuring and Using BMI and Other Indicators of Obesity in Children
Himes, J. H. (2009) · Pediatrics · doi:10.1542/peds.2008-3586d · Cited by 220
Kyle, U. G., Earthman, C. P., Pichard, C., & Coss-Bu, J. A. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2015.86 · Cited by 183
Bioelectrical impedance underestimates total and truncal fatness in abdominally obese women
Neovius, M., Hemmingsson, E., Freyschuss, B., & Uddén, J. (2006) · Obesity · doi:10.1038/oby.2006.199 · Cited by 119
Metadata
- Authors
- Lazzer, S., Boirie, Y., Meyer, M., & Vermorel, M.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2003-11
- Volume
- 90
- Issue
- 5
- Pages
- 987-992
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2053344057
- Cited by
- 107
- References
- 4
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.