Cited by 119Body Composition Measurement TechniquesObesity, Physical Activity, DietElectrical and Bioimpedance Tomography

Bioelectrical impedance underestimates total and truncal fatness in abdominally obese women

Open access
Neovius, Martin, Hemmingsson, Erik, Freyschuss, Bo, Uddén, Joanna·2006·Obesity

Abstract

OBJECTIVE: To compare estimates of total and truncal fatness from eight-electrode bioelectrical impedance analysis equipment (BIA(8)) with those from DXA in centrally obese women. The secondary aim was to examine BMI and waist circumference (WC) as proxy measures for percentage total body fat (%TBF) and truncal body fat percentage (tr%BF). RESEARCH METHODS AND PROCEDURES: This was a cross-sectional study of 136 women (age, 48.1 +/- 7.7 years; BMI, 30.4 +/- 2.9 kg/m(2); %TBF(DXA), 46.0 +/- 3.7%; WC, 104 +/- 8 cm). Fatness was measured by DXA and Tanita BC-418 equipment (Tanita Corp., Tokyo, Japan). Agreement among methods was assessed by Bland-Altman plots, and regression analysis was used to evaluate anthropometric measures as proxies for total and abdominal fatness. RESULTS: The percentage of overweight subjects was 41.9%, whereas 55.9% of the subjects were obese, as defined by BMI, and all subjects had a WC exceeding the World Health Organization cut-off point for abdominal obesity. Compared with DXA, the BIA(8) equipment significantly underestimated total %BF (-5.0; -3.6 to -8.5 [mean; 95% confidence interval]), fat mass (-3.6; -3.9 to -3.2), and tr%BF (-8.5; -9.1 to -7.9). The discrepancies between the methods increased with increasing adiposity for both %TBF and tr%BF (both p < 0.001). Variation in BMI explained 28% of the variation in %TBF(DXA) and 51% of %TBF(BIA8). Using WC as a proxy for truncal adiposity, it explained only 18% of tr%BF(DXA) variance and 27% of tr%BF(BIA8) variance. The corresponding figures for truncal fat mass were 49% and 35%, respectively. No significant age effects were observed in any of the regressions. DISCUSSION: BIA(8) underestimated both total and truncal fatness, compared with DXA, with higher dispersion for tr%BF than %TBF. The discrepancies increased with degree of adiposity, suggesting that the accuracy of BIA is negatively affected by obesity.

Integrity signals

Registry

Crossref · 10.1038/oby.2006.199

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Single-frequency devices and segmental measures demonstrate the largest differences when compared to DXA, with the inaccuracy increasing in conjunction with higher levels of BMI.

    “However, single-frequency devices and segmental measures demonstrate the largest differences when compared to DXA, with the inaccuracy increasing in conjunction with higher levels of BMI [55,56,57,58].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Neovius, M., Hemmingsson, E., Freyschuss, B., & Uddén, J.
Affiliations
Karolinska University Hospital (SE)
Corresponding author
Neovius, Martin
Venue
Obesity
Publisher
Wiley
Published
2006-10
Volume
14
Issue
10
Pages
1731-1738
ISSN
  • 1930-7381 (ISSN-L)
  • 1930-739X
OpenAlex
W2045851722
Cited by
119
References
27
Citations by year
2025: 4 · 2024: 4 · 2023: 3 · 2022: 6 · 2021: 6 · 2020: 6 · 2019: 4 · 2018: 7 · 2017: 6 · 2016: 6 · 2015: 3 · 2014: 8 · 2013: 8 · 2012: 9
FWCI
5.32
Type
journal article
Language
en
Open access
Locations
  • Obesity (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
Keywords
bioelectrical impedance analysis, truncal fat, total body fat, abdominal obesity, women, dual-energy X-ray absorptiometry, fat mass, waist circumference, body mass index, adiposity, measurement agreement, fat-free mass
MeSH terms
Adult, Aged, Body Composition, Cross-Sectional Studies, Female, Humans, Middle Aged, Obesity, Reproducibility of Results, Absorptiometry, Photon, Body Mass Index, Electric Impedance, Waist-Hip Ratio, Abdominal Fat, Adiposity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.